Joaquín Berrocal
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joaquín Berrocal has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Daniel Rodríguez
Universidad de Granada
11 shared publications - Michael Block
Johannes Gutenberg-Universität Mainz
10 shared publications - Francisco Domínguez
Universidad de Granada
7 shared publications - Manuel J. Gutiérrez
Departamento de Física Atómica, Molecular y Nuclear, Universidad de Granada, 18071 Granada, Spain
5 shared publications - Francisco J. Fernandez
Departamento de Arquitectura y Tecnología de Computadores, Universidad de Granada, 18071 Granada, Spain
3 shared publications - Emilio Altozano
Servicio de Radiofísica y Protección Radiológica, Hospital Universitario Virgen de las Nieves
2 shared publications
Latest Publications
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet
In this work, we investigate the magnetic-field stability of a Penning trap operated with a cryogen-free superconducting magnet through cyclotron-frequency measurements of a single laser-cooled calcium ion using two complementary photon-based detection techniques: a pulsed optical method for determining the three ion eigenfrequencies and Fluorescence-Detected Fourier-Transform Ion-Cyclotron-Resonance (FD-FT-ICR). For the former technique, the data-analysis procedure was revisited, considering it as the dominant contribution to the measurement uncertainty and yielding a long-term magnetic-field drift (1/B)(dB/dt) = −3.07(32) × 10−9 h−1. This value is comparable with those reported for high-precision Penning-trap experiments employing liquid-helium-based superconducting magnets. The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of δB/B ≃ 5 × 10−8 for averaging times between 30 and 60 s. Furthermore, this technique enables direct cyclotron-frequency determinations on timescales as short as a few seconds, providing access to magnetic-field fluctuations that are generally not resolved in conventional Penning-trap experiments.
- 1 November 2026
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 97 (11)
Cyclotron-frequency stability via single-ion fluorescence in a Penning trap with a cryogen-free superconducting magnet
In this work, we investigate the magnetic-field stability of a Penning trap operated with a cryogen-free superconducting magnet through cyclotron-frequency measurements of a single laser-cooled calcium ion using two complementary photon-based detection techniques: a pulsed optical method for determining the three ion eigenfrequencies and Fluorescence-Detected Fourier-Transform Ion-Cyclotron-Resonance (FD-FT-ICR). For the former technique, the data-analysis procedure was revisited, considering it as the dominant contribution to the measurement uncertainty and yielding a long-term magnetic-field drift (1/B)(dB/dt) = −3.07(32) × 10−9 h−1. This value is comparable with those reported for high-precision Penning-trap experiments employing liquid-helium-based superconducting magnets. The short-term stability was investigated using the FD-FT-ICR technique, resulting in a minimum relative magnetic-field variation of δB/B ≃ 5 × 10−8 for averaging times between 30 and 60 s. Furthermore, this technique enables direct cyclotron-frequency determinations on timescales as short as a few seconds, providing access to magnetic-field fluctuations that are generally not resolved in conventional Penning-trap experiments.
- 10 December 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (6)
Laser-assisted motional-mode spectroscopy in a Penning trap and the generalized invariance theorem
- 10 December 2024
- Published by American Physical Society (APS) in Physical Review A
- Vol. 110 (6)
Laser-assisted motional-mode spectroscopy in a Penning trap and the generalized invariance theorem
- Open Access
- 10 December 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (4)
Enhancing nondestructive mass identification via Fourier-transform fluorescence analysis
Single-ion mass identification is important for atomic and nuclear physics experiments on ions produced with low yields. Cooling the ion to ultralow temperatures through interaction with a laser-cooled ion will enhance the precision of the measurements. In this paper we present axial-common-mode frequency measurements of balanced and unbalanced Coulomb crystals from the Fourier transform of the fluorescence photons from a Doppler-cooling transition in calcium ions after probing the ion crystal with a five-radio-frequency comb. A single ion nondestructively detected can be used for identification, yielding a mass-resolving power m / Δ m FWHM ≈ 310 from the axial common mode. This identification can be performed from a single measurement within times below 1 s. Published by the American Physical Society 2024
- 10 December 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (4)
Open AccessEnhancing nondestructive mass identification via Fourier-transform fluorescence analysis
Single-ion mass identification is important for atomic and nuclear physics experiments on ions produced with low yields. Cooling the ion to ultralow temperatures through interaction with a laser-cooled ion will enhance the precision of the measurements. In this paper we present axial-common-mode frequency measurements of balanced and unbalanced Coulomb crystals from the Fourier transform of the fluorescence photons from a Doppler-cooling transition in calcium ions after probing the ion crystal with a five-radio-frequency comb. A single ion nondestructively detected can be used for identification, yielding a mass-resolving power m / Δ m FWHM ≈ 310 from the axial common mode. This identification can be performed from a single measurement within times below 1 s. Published by the American Physical Society 2024
- Open Access
- 3 January 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (1) , L012001
Penning-trap eigenfrequency measurements with optical radiofrequency detectors
We use an electric-dipole laser-driven transition to precisely measure the cyclotron-frequency ratios of the pairs , and in a 7-tesla Penning trap. A single laser-cooled ( mK) ion serves, together with photon-counting and photon-imaging units, as a radiofrequency detector covering a broadband frequency spectrum, in the present case from kHz to a few MHz. Such detectors () allow measuring extremely small forces increasing the sensitivity in Penning-trap mass spectrometry. The direct determination of the ions' amplitudes makes a cyclotron-frequency measurement process more robust against inhomogeneities of the magnetic field and/or deviations of the electric quadrupole field due to mechanical imperfections of the trap.- 3 January 2024
- Published by American Physical Society (APS) in Physical Review Research
- Vol. 6 (1) , L012001
Open AccessPenning-trap eigenfrequency measurements with optical radiofrequency detectors
We use an electric-dipole laser-driven transition to precisely measure the cyclotron-frequency ratios of the pairs , and in a 7-tesla Penning trap. A single laser-cooled ( mK) ion serves, together with photon-counting and photon-imaging units, as a radiofrequency detector covering a broadband frequency spectrum, in the present case from kHz to a few MHz. Such detectors () allow measuring extremely small forces increasing the sensitivity in Penning-trap mass spectrometry. The direct determination of the ions' amplitudes makes a cyclotron-frequency measurement process more robust against inhomogeneities of the magnetic field and/or deviations of the electric quadrupole field due to mechanical imperfections of the trap. - 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093304
A frequency comb stabilized Ti:Sa laser as a self-reference for ion-trap experiments with a 40Ca+ ion
In this study, we report on the stabilization of a continuous-wave Ti:Sa laser to an optical frequency comb. The laser is emitting at 866 nm to address one of the transitions required for Doppler cooling of a single 40Ca+ ion in a linear Paul trap (2D3/2 ). The stabilized Ti:Sa laser is utilized to calibrate an ultra-accurate wavelength meter. We certify this self-reference laser source by comparing the results from monitoring the laser-cooled 40Ca+ ion in the linear Paul trap, with those obtained when a HeNe laser is used for calibration. The use of this self-reference is compatible with the simultaneous use of the comb for precision spectroscopy in the same ion-trap experiment.- 1 September 2022
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 93 (9) , 093304
A frequency comb stabilized Ti:Sa laser as a self-reference for ion-trap experiments with a 40Ca+ ion
In this study, we report on the stabilization of a continuous-wave Ti:Sa laser to an optical frequency comb. The laser is emitting at 866 nm to address one of the transitions required for Doppler cooling of a single 40Ca+ ion in a linear Paul trap (2D3/2 ). The stabilized Ti:Sa laser is utilized to calibrate an ultra-accurate wavelength meter. We certify this self-reference laser source by comparing the results from monitoring the laser-cooled 40Ca+ ion in the linear Paul trap, with those obtained when a HeNe laser is used for calibration. The use of this self-reference is compatible with the simultaneous use of the comb for precision spectroscopy in the same ion-trap experiment.- Open Access
A Coupled-Oscillators Model to Analyze the Interaction between a Quartz Resonator and Trapped Ions
The novel application of a piezoelectric quartz resonator for the detection of trapped ions has developed in the observation of the quartz-ions interaction under non-equilibrium conditions, opening new perspectives for high-sensitive motional frequency measurements of radioactive particles. Energized quartz crystals have (long) constant-decay times in the order of milliseconds, permitting the coherent detection of charged particles within short times. In this publication we develop in detail a model governing the interaction between trapped $^{40}$Ca$^+$ ions and a quartz resonator connected to a low-noise amplifier. We apply this model to experimental data and extract relevant information like the coupling constant $g=2\pi \times 1.449(2)$~Hz and the ions' modified-cyclotron frequency in our 7-tesla Penning trap. The study on the latter is specially important for the use of this resonator in precision Penning-trap mass spectrometry. The improvement in sensitivity can be accomplished by increasing the coupling constant through the quality factor of the resonator. This can develop in the use of the hybrid quartz-ion system for other applications.Open AccessA Coupled-Oscillators Model to Analyze the Interaction between a Quartz Resonator and Trapped Ions
The novel application of a piezoelectric quartz resonator for the detection of trapped ions has developed in the observation of the quartz-ions interaction under non-equilibrium conditions, opening new perspectives for high-sensitive motional frequency measurements of radioactive particles. Energized quartz crystals have (long) constant-decay times in the order of milliseconds, permitting the coherent detection of charged particles within short times. In this publication we develop in detail a model governing the interaction between trapped $^{40}$Ca$^+$ ions and a quartz resonator connected to a low-noise amplifier. We apply this model to experimental data and extract relevant information like the coupling constant $g=2\pi \times 1.449(2)$~Hz and the ions' modified-cyclotron frequency in our 7-tesla Penning trap. The study on the latter is specially important for the use of this resonator in precision Penning-trap mass spectrometry. The improvement in sensitivity can be accomplished by increasing the coupling constant through the quality factor of the resonator. This can develop in the use of the hybrid quartz-ion system for other applications. - 16 May 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 105 (5) , 052603
Formation of two-ion crystals by injection from a Paul-trap source into a high-magnetic-field Penning trap
Two-ion crystals constitute a platform for investigations of quantum nature that can be extended to any ion species or charged particle provided one of the ions in the crystal can be directly laser cooled and manipulated with laser radiation. This paper presents the formation of two-ion crystals for quantum metrology in a 7-tesla open-ring Penning trap. ions are produced either internally by photoionization or externally in a (Paul-trap) source, transported through the strong magnetic field gradient of the superconducting solenoid, and captured in-flight with a mean kinetic energy of a few electronvolts with respect to the minimum of the Penning-trap potential well. Laser cooling of the two-ion crystal in a strong magnetic field towards reaching the quantum regime is also presented, with particular emphasis on the cooling of the radial modes.- 16 May 2022
- Published by American Physical Society (APS) in Physical Review A
- Vol. 105 (5) , 052603
Formation of two-ion crystals by injection from a Paul-trap source into a high-magnetic-field Penning trap
Two-ion crystals constitute a platform for investigations of quantum nature that can be extended to any ion species or charged particle provided one of the ions in the crystal can be directly laser cooled and manipulated with laser radiation. This paper presents the formation of two-ion crystals for quantum metrology in a 7-tesla open-ring Penning trap. ions are produced either internally by photoionization or externally in a (Paul-trap) source, transported through the strong magnetic field gradient of the superconducting solenoid, and captured in-flight with a mean kinetic energy of a few electronvolts with respect to the minimum of the Penning-trap potential well. Laser cooling of the two-ion crystal in a strong magnetic field towards reaching the quantum regime is also presented, with particular emphasis on the cooling of the radial modes.- Open Access
- 14 May 2021
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 6 (4) , 044002
Non-equilibrium coupling of a quartz resonator to ions for Penning-trap fast resonant detection
The coherent coupling between a quartz electro-mechanical resonator at room temperature and trapped ions in a 7 T Penning trap has been demonstrated for the first time. The signals arising from the coupling remain for integration times in the orders of seconds. From the measurements carried out, we demonstrate that the coupling allows detecting the reduced-cyclotron frequency (ν +) within times in the order of the decay-time constant of the energized resonator (below 10 ms), regardless of the data-acquisition time-window in use, and providing an improved resolution compared to conventional electronic detection schemes. A resolving power ν +/Δν + = 2.4 × 107 has been reached in single measurements. In this publication we present the first results, emphasizing the novel features of the quartz resonator as fast non-destructive ion-trap detector together with different ways to analyze the data and considering aspects like precision, resolution and sensitivity.
- 14 May 2021
- Published by IOP Publishing in Quantum Science and Technology
- Vol. 6 (4) , 044002
Open AccessNon-equilibrium coupling of a quartz resonator to ions for Penning-trap fast resonant detection
The coherent coupling between a quartz electro-mechanical resonator at room temperature and trapped ions in a 7 T Penning trap has been demonstrated for the first time. The signals arising from the coupling remain for integration times in the orders of seconds. From the measurements carried out, we demonstrate that the coupling allows detecting the reduced-cyclotron frequency (ν +) within times in the order of the decay-time constant of the energized resonator (below 10 ms), regardless of the data-acquisition time-window in use, and providing an improved resolution compared to conventional electronic detection schemes. A resolving power ν +/Δν + = 2.4 × 107 has been reached in single measurements. In this publication we present the first results, emphasizing the novel features of the quartz resonator as fast non-destructive ion-trap detector together with different ways to analyze the data and considering aspects like precision, resolution and sensitivity.
- 1 September 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (9) , 093202
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneously trapped ions (≈100) and will decrease to a negligible level once we reach single-ion sensitivity. The compactness of such a crystal makes this approach promising for direct Penning-trap mass measurements on heavy and superheavy elements.- 1 September 2020
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 91 (9) , 093202
Quartz resonators for penning traps toward mass spectrometry on the heaviest ions
We report on cyclotron frequency measurements on trapped 206,207Pb+ ions by means of the non-destructive Fourier-transform ion-cyclotron-resonance technique at room temperature. In a proof-of-principle experiment using a quartz crystal instead of a coil as a resonator, we have alternately carried out cyclotron frequency measurements for 206Pb+ and 207Pb+ with the sideband coupling method to obtain 21 cyclotron-frequency ratios with a statistical uncertainty of 6 × 10−7. The mean frequency ratio deviates by about 2σ from the value deduced from the masses reported in the latest Atomic Mass Evaluation. We anticipate that this shift is due to the ion–ion interaction between the simultaneously trapped ions (≈100) and will decrease to a negligible level once we reach single-ion sensitivity. The compactness of such a crystal makes this approach promising for direct Penning-trap mass measurements on heavy and superheavy elements.- 10 December 2019
- Published by American Physical Society (APS) in Physical Review A
- Vol. 100 (6) , 063415
Dynamics of an unbalanced two-ion crystal in a Penning trap for application in optical mass spectrometry
In this paper, the dynamics of an unbalanced two-ion crystal comprising the “target” and the “sensor” ions confined in a Penning trap along the magnetic-field axis has been studied. First, the low amplitude regime is addressed. In this regime, the overall potential including the Coulomb repulsion between the ions can be considered harmonic and the axial, magnetron, and reduced-cyclotron modes split up into the so-called stretch and common modes, that are generalizations of the well-known “breathing” and “center-of-mass” motions of a balanced crystal made of two ions. By using optical detection to measure the frequencies of the modes of the crystal, and of the sensor ion on its own, in the quantum regime of motion, it will be possible to determine the target ion's free-cyclotron frequency. The nonharmonicity of the Coulomb interaction is also discussed since this causes large systematic effects, which are minimized due to the high sensitivity of the optical detection method when the crystal is cooled to the ground state of motion in the Penning trap.
- 10 December 2019
- Published by American Physical Society (APS) in Physical Review A
- Vol. 100 (6) , 063415
Dynamics of an unbalanced two-ion crystal in a Penning trap for application in optical mass spectrometry
In this paper, the dynamics of an unbalanced two-ion crystal comprising the “target” and the “sensor” ions confined in a Penning trap along the magnetic-field axis has been studied. First, the low amplitude regime is addressed. In this regime, the overall potential including the Coulomb repulsion between the ions can be considered harmonic and the axial, magnetron, and reduced-cyclotron modes split up into the so-called stretch and common modes, that are generalizations of the well-known “breathing” and “center-of-mass” motions of a balanced crystal made of two ions. By using optical detection to measure the frequencies of the modes of the crystal, and of the sensor ion on its own, in the quantum regime of motion, it will be possible to determine the target ion's free-cyclotron frequency. The nonharmonicity of the Coulomb interaction is also discussed since this causes large systematic effects, which are minimized due to the high sensitivity of the optical detection method when the crystal is cooled to the ground state of motion in the Penning trap.