Daniela López
Research Subjects
Daniela López has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Daniela Salinas-Toro
Fundación Oftalmológica Los Andes Ophthalmology Clinic (FOLA), Las Hualtatas 5951, Vitacura, Postal code 7650710, Santiago, Chile
2 shared publications - Felipe Valenzuela
Fundación Oftalmológica Los Andes (FOLA), Santiago, Chile
2 shared publications - Héctor Toledo
Programa de Biología Celular y Molecular, ICBM, Facultad de Medicina, Universidad de Chile, Avenida Independencia 1027, Casilla 70086, Santiago-7, Chile
2 shared publications - Leonidas Traipe-Castro
Fundación Oftalmológica Los Andes (FOLA), Santiago, Chile
2 shared publications - Remigio López-Solís
Program of Cellular and Molecular Biology, Faculty of Medicine-ICBM, University of Chile, Independencia 1027, Santiago, Chile
2 shared publications - Aníbal Cáceres
Cellular and Molecular Biology Program, Faculty of Medicine-ICBM, University of Chile, 1027, Independencia, 8380453, Santiago, Chile
1 shared publication
Latest Publications
- Open Access
- 3 June 2016
- Published by Springer Nature in Biological Research
- Vol. 49 (1) , 28
Progress in tear microdesiccate analysis by combining various transmitted-light microscope techniques
Tear desiccation on a glass surface followed by transmitted-light microscopy has served as diagnostic test for dry eye. Four distinctive morphological domains (zones I, II, III and transition band) have been recently recognized in tear microdesiccates. Physicochemical dissimilarities among those domains hamper comprehensive microscopic examination of tear microdesiccates. Optimal observation conditions of entire tear microdesiccates are now investigated. One-μl aliquots of tear collected from individual healthy eyes were dried at ambient conditions on microscope slides. Tear microdesiccates were examined by combining low-magnification objective lenses with transmitted-light microscopy (brightfield, phase contrasts Ph1,2,3 and darkfield). Fern-like structures (zones II and III) were visible with all illumination methods excepting brightfield. Zone I was the microdesiccate domain displaying the most noticeable illumination-dependent variations, namely transparent band delimited by an outer rim (Ph1, Ph2), homogeneous compactly built structure (brightfield) or invisible domain (darkfield, Ph3). Intermediate positions of the condenser (BF/Ph1, Ph1/Ph2) showed a structured roughly cylindrical zone I. The transition band also varied from invisibility (brightfield) to a well-defined domain comprising interwoven filamentous elements (phase contrasts, darkfield). Imaging of entire tear microdesiccates by transmitted-light microscopy depends upon illumination. A more comprehensive description of tear microdesiccates can be achieved by combining illumination methods.
- 3 June 2016
- Published by Springer Nature in Biological Research
- Vol. 49 (1) , 28
Open AccessProgress in tear microdesiccate analysis by combining various transmitted-light microscope techniques
Tear desiccation on a glass surface followed by transmitted-light microscopy has served as diagnostic test for dry eye. Four distinctive morphological domains (zones I, II, III and transition band) have been recently recognized in tear microdesiccates. Physicochemical dissimilarities among those domains hamper comprehensive microscopic examination of tear microdesiccates. Optimal observation conditions of entire tear microdesiccates are now investigated. One-μl aliquots of tear collected from individual healthy eyes were dried at ambient conditions on microscope slides. Tear microdesiccates were examined by combining low-magnification objective lenses with transmitted-light microscopy (brightfield, phase contrasts Ph1,2,3 and darkfield). Fern-like structures (zones II and III) were visible with all illumination methods excepting brightfield. Zone I was the microdesiccate domain displaying the most noticeable illumination-dependent variations, namely transparent band delimited by an outer rim (Ph1, Ph2), homogeneous compactly built structure (brightfield) or invisible domain (darkfield, Ph3). Intermediate positions of the condenser (BF/Ph1, Ph1/Ph2) showed a structured roughly cylindrical zone I. The transition band also varied from invisibility (brightfield) to a well-defined domain comprising interwoven filamentous elements (phase contrasts, darkfield). Imaging of entire tear microdesiccates by transmitted-light microscopy depends upon illumination. A more comprehensive description of tear microdesiccates can be achieved by combining illumination methods.
- Open Access
- 4 June 2014
- Published by Springer Nature in Biological Research
- Vol. 47 (1) , 1-10
Dynamics of tear fluid desiccation on a glass surface: a contribution to tear quality assessment
Fern-like crystalloids form when a microvolume of tear is allowed to dry out at ambient conditions on a glass surface. Presence of crystalloids in tear “microdesiccates” is used to evaluate patients with Dry-Eye disease. This study aims to examine morphologically the desiccation process of normal tear fluid and to identify changes associated with accelerated tear evaporation. Tear microdesiccates from healthy (Non-Dry Eye) and Dry Eye subjects were produced at ambient conditions. Microdesiccate formation was monitored continuously by dark-field video microscopy. Additionally, accelerated desiccation of tear samples from healthy subjects was conducted under controlled experimental conditions. Particular morphological domains of tear microdesiccates and their progressive appearance during desiccation were compared. In normal tear microdesiccates, four distinctive morphological domains (zones I, II, III and transition band) were recognized. Stepwise formation of those domains is now described. Experimentally accelerated desiccation resulted in marked changes in some of those zones, particularly involving either disappearance or size reduction of fern-like crystalloids of zones II and III. Tear microdesiccates from Dry Eye subjects may also display those differences and be the expression of a more synchronous formation of microdesiccate domains. Morphological characteristics of tear microdesiccates can provide insights into the relative rate of tear evaporation.
- 4 June 2014
- Published by Springer Nature in Biological Research
- Vol. 47 (1) , 1-10
Open AccessDynamics of tear fluid desiccation on a glass surface: a contribution to tear quality assessment
Fern-like crystalloids form when a microvolume of tear is allowed to dry out at ambient conditions on a glass surface. Presence of crystalloids in tear “microdesiccates” is used to evaluate patients with Dry-Eye disease. This study aims to examine morphologically the desiccation process of normal tear fluid and to identify changes associated with accelerated tear evaporation. Tear microdesiccates from healthy (Non-Dry Eye) and Dry Eye subjects were produced at ambient conditions. Microdesiccate formation was monitored continuously by dark-field video microscopy. Additionally, accelerated desiccation of tear samples from healthy subjects was conducted under controlled experimental conditions. Particular morphological domains of tear microdesiccates and their progressive appearance during desiccation were compared. In normal tear microdesiccates, four distinctive morphological domains (zones I, II, III and transition band) were recognized. Stepwise formation of those domains is now described. Experimentally accelerated desiccation resulted in marked changes in some of those zones, particularly involving either disappearance or size reduction of fern-like crystalloids of zones II and III. Tear microdesiccates from Dry Eye subjects may also display those differences and be the expression of a more synchronous formation of microdesiccate domains. Morphological characteristics of tear microdesiccates can provide insights into the relative rate of tear evaporation.