Yangxiao Xiang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yangxiao Xiang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Xuejun Pei
Huazhong University of Science and Technology
4 shared publications - Yong Kang
Electrical and Electronic Engineering, Huazhong University of Science and Technology, Wuhan, Hubei China 430074
3 shared publications - Hai Wang
Murdoch University
2 shared publications - Meijuan Wang
Huazhong University of Science and Technology, 12443 Wuhan, Hubei, China
2 shared publications - Chunyu Yang
Huazhong University of Science and Technology, 12443 Wuhan, Hubei, China
1 shared publication - Peng Zhou
Huazhong University of Science and Technology, 12443 Wuhan, Hubei, China
1 shared publication
Latest Publications
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (11) , 10436-10448
A Separate Floating Heatsink Based Suppression Method for Conducted Common-Mode EMI
In order to effectively suppress the intractable high-frequency conducted common-mode (CM) electromagnetic interference (EMI) and reduce the dependence on the high-frequency performance of the EMI filter, this paper proposes a separate floating heatsink based suppression method (SFHBSM). SFHBSM suppresses high-frequency CM EMI by improving both the CM EMI source and the propagation path. On the one hand, SFHBSM achieves the non-ringing CM EMI source without introducing additional resistive loss, by properly designing the parameters of the SFHBSM, the ringing effect in the CM EMI source can be pushed into a narrow bandwidth in the very high-frequency domain, where the ringing effect can be naturally killed by the skin effect. On the other hand, the CM EMI propagation path of the SFHBSM based power converter is mathematically deduced, verifying that the SFHBSM can provide effective blocking for the CM EMI propagation in the high-frequency domain. Experiments show that under the combined effect of the ringing suppression and propagation blocking, SFHBSM achieves EMI reduction in almost the whole high-frequency domain, and provides up to 35dB attenuation in a two-level three-phase power converter. Besides, ablation experiments have been conducted to evaluate the individual and combined effectiveness of each part of the SFHBSM.
- 1 November 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 68 (11) , 10436-10448
A Separate Floating Heatsink Based Suppression Method for Conducted Common-Mode EMI
In order to effectively suppress the intractable high-frequency conducted common-mode (CM) electromagnetic interference (EMI) and reduce the dependence on the high-frequency performance of the EMI filter, this paper proposes a separate floating heatsink based suppression method (SFHBSM). SFHBSM suppresses high-frequency CM EMI by improving both the CM EMI source and the propagation path. On the one hand, SFHBSM achieves the non-ringing CM EMI source without introducing additional resistive loss, by properly designing the parameters of the SFHBSM, the ringing effect in the CM EMI source can be pushed into a narrow bandwidth in the very high-frequency domain, where the ringing effect can be naturally killed by the skin effect. On the other hand, the CM EMI propagation path of the SFHBSM based power converter is mathematically deduced, verifying that the SFHBSM can provide effective blocking for the CM EMI propagation in the high-frequency domain. Experiments show that under the combined effect of the ringing suppression and propagation blocking, SFHBSM achieves EMI reduction in almost the whole high-frequency domain, and provides up to 35dB attenuation in a two-level three-phase power converter. Besides, ablation experiments have been conducted to evaluate the individual and combined effectiveness of each part of the SFHBSM.
- 6 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10650-10664
A Fast and Precise Method for Modeling EMI Source in Two-Level Three-Phase Converter
Currently, frequency-domain electromagnetic interference (EMI) modeling has become the most commonly used method for EMI prediction and filter design. However, because of the unpredictability of the ringing effect in the present frequency-domain EMI modeling methods, the precision of the predicted EMI interference source is notably limited, which results in the inaccuracy of the system level EMI prediction. In order to achieve an accurate EMI prediction, this study presents a systematical study on the interference source of a 10 kVA three-phase bridge converter. The precise mathematical models of the common-mode and differential-mode interference source are constructed. Then, the characteristics of the multiple ringing effect, which is an important part of the interference source, are intensively analyzed. Based on the investigation of interference source, an improved interference source synthesis method is proposed. It can quickly and precisely predict the CM and DM interference source with multiple ringing effect, which can be used to achieve accurate frequency domain EMI prediction. Moreover, the multiple ringing effect is extended for IGBT parasitic parameter measuring. Instead of complicated device-level measurement, the grounding capacitance and junction capacitance can be effectively extracted through the ringing frequency measurement.
- 6 January 2019
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (11) , 10650-10664
A Fast and Precise Method for Modeling EMI Source in Two-Level Three-Phase Converter
Currently, frequency-domain electromagnetic interference (EMI) modeling has become the most commonly used method for EMI prediction and filter design. However, because of the unpredictability of the ringing effect in the present frequency-domain EMI modeling methods, the precision of the predicted EMI interference source is notably limited, which results in the inaccuracy of the system level EMI prediction. In order to achieve an accurate EMI prediction, this study presents a systematical study on the interference source of a 10 kVA three-phase bridge converter. The precise mathematical models of the common-mode and differential-mode interference source are constructed. Then, the characteristics of the multiple ringing effect, which is an important part of the interference source, are intensively analyzed. Based on the investigation of interference source, an improved interference source synthesis method is proposed. It can quickly and precisely predict the CM and DM interference source with multiple ringing effect, which can be used to achieve accurate frequency domain EMI prediction. Moreover, the multiple ringing effect is extended for IGBT parasitic parameter measuring. Instead of complicated device-level measurement, the grounding capacitance and junction capacitance can be effectively extracted through the ringing frequency measurement.
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5352-5361
An Improved H8 Topology for Common-Mode Voltage Reduction
This paper presents an improved H8 power converter for common-mode voltage (CMV) reduction and electromagnetic interference suppression. The proposed H8 converter can realize zero CMV variation when entering and leaving the zero state, which is mainly achieved by both the improvement of the structure and the control strategy. For the system structure, two switches are added on the dc bus to float the ac part of the three-phase converter in the zero state. Besides, additional capacitors are used to realize controllable CMV. For the control strategy, a simple control strategy is proposed for the H8 converter. It can automatically adapt to the flowing orientation of the load current to realize synchronous switching of the power switches, which effectively eliminates the impact of the dead time. Through analysis, simulations, and experiment, a comparison between the proposed H8 converter and the conventional H6 converter is performed. Results validate the effectiveness of the H8 topology.
- 13 September 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Power Electronics
- Vol. 34 (6) , 5352-5361
An Improved H8 Topology for Common-Mode Voltage Reduction
This paper presents an improved H8 power converter for common-mode voltage (CMV) reduction and electromagnetic interference suppression. The proposed H8 converter can realize zero CMV variation when entering and leaving the zero state, which is mainly achieved by both the improvement of the structure and the control strategy. For the system structure, two switches are added on the dc bus to float the ac part of the three-phase converter in the zero state. Besides, additional capacitors are used to realize controllable CMV. For the control strategy, a simple control strategy is proposed for the H8 converter. It can automatically adapt to the flowing orientation of the load current to realize synchronous switching of the power switches, which effectively eliminates the impact of the dead time. Through analysis, simulations, and experiment, a comparison between the proposed H8 converter and the conventional H6 converter is performed. Results validate the effectiveness of the H8 topology.
- 24 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (6) , 4684-4695
Switch Fault Diagnosis Method for Series–Parallel Forward DC–DC Converter System
Series-parallel forward dc-dc converter system is a good option in high-voltage high-power applications. A switch fault, in this converter, should be detected as soon as possible, to avoid further damage and save maintenance cost. In this paper, a new switch fault diagnosis method, which treats output inductor voltages as diagnostic criteria, is proposed for this system. With the proposed method, expensive sensors are needless, since diagnostic signal can be easily acquired by adding a small auxiliary winding into inductor magnetic core. Based on the feature of diagnostic signals in such system, a low-cost diagnostic circuit is designed. The failed module caused by open circuit fault or short circuit fault could be detected within one switching period, allowing for an immediate fault-tolerant action. This method also shows generality for different connections and buck-type isolated topologies. Besides, it works reliably under input-voltage variation and load step, and no misdiagnosis will occur during normal dynamic process. Finally, experimental result verifies the effectiveness of this method. The proposed scheme has a good potential to be applied in real applications for its simplicity and robustness.
- 24 August 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Industrial Electronics
- Vol. 66 (6) , 4684-4695
Switch Fault Diagnosis Method for Series–Parallel Forward DC–DC Converter System
Series-parallel forward dc-dc converter system is a good option in high-voltage high-power applications. A switch fault, in this converter, should be detected as soon as possible, to avoid further damage and save maintenance cost. In this paper, a new switch fault diagnosis method, which treats output inductor voltages as diagnostic criteria, is proposed for this system. With the proposed method, expensive sensors are needless, since diagnostic signal can be easily acquired by adding a small auxiliary winding into inductor magnetic core. Based on the feature of diagnostic signals in such system, a low-cost diagnostic circuit is designed. The failed module caused by open circuit fault or short circuit fault could be detected within one switching period, allowing for an immediate fault-tolerant action. This method also shows generality for different connections and buck-type isolated topologies. Besides, it works reliably under input-voltage variation and load step, and no misdiagnosis will occur during normal dynamic process. Finally, experimental result verifies the effectiveness of this method. The proposed scheme has a good potential to be applied in real applications for its simplicity and robustness.