Seung-Ki Pang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Seung-Ki Pang has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Jong-Gwan Yook
Yonsei University
3 shared publications - Jinwon Shin
Department of Architectural Engineering, Catholic Kwandong University, Gangneung 25601, Korea
2 shared publications - Yuna Kim
Department of Electrical and Electronic Engineering, Yonsei University, Seoul 30722, South Korea
2 shared publications - Dong-Keon Kim
Department of Architectural Engineering, Dong-A University, Busan 49315, Republic of Korea
1 shared publication Hye-Rin Ahn
1 shared publication- Jae-Hun Kim
Department of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea
1 shared publication
Latest Publications
- Open Access
- 26 March 2024
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 147
Enhancing blast mitigation in tunnels with expansion chamber subjected to high explosives detonations for protecting underground facilities
- 26 March 2024
- Published by Elsevier in Tunnelling and Underground Space Technology
- Vol. 147
Open AccessEnhancing blast mitigation in tunnels with expansion chamber subjected to high explosives detonations for protecting underground facilities
- Open Access
- 30 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1759
Effects of Entrance Shape and Blast Pocket on Internal Overpressure Mitigation for Protective Tunnels Exposed to External Detonation on the Ground
This study presents a numerical analysis to reduce the overpressure inside protective tunnels for external detonations. A three-dimensional computational fluid dynamics model of a tunnel subjected to detonation for a hemispherical charge with a charge weight of 555 kg and a standoff distance of 7.6 m was established, based on a mesh sensitivity study to obtain an optimal element size, stability analysis of overpressure, and validation study to evaluate the accuracy of the numerical results based on Unified Facilities Criteria (UFC) 3-340-02. A parametric analysis was performed using the validated numerical model to investigate the effects of the entrance shape and blast pockets on the reduction in the maximum overpressure. The maximum overpressures were effectively reduced as the slope angle of the tunnel entrance decreased and the length of the blast pocket divided by the tunnel width decreased. An optimized shape of the tunnel was proposed based on the numerical results, where the peak overpressures were reduced by a maximum of 64.5%. This study aims to protect facilities, personnel, and equipment and further reduce construction costs by lowering the overpressure rating of blast valves in protective tunnels.
- 30 January 2023
- Published by MDPI AG in Applied Sciences
- Vol. 13 (3) , 1759
Open AccessEffects of Entrance Shape and Blast Pocket on Internal Overpressure Mitigation for Protective Tunnels Exposed to External Detonation on the Ground
This study presents a numerical analysis to reduce the overpressure inside protective tunnels for external detonations. A three-dimensional computational fluid dynamics model of a tunnel subjected to detonation for a hemispherical charge with a charge weight of 555 kg and a standoff distance of 7.6 m was established, based on a mesh sensitivity study to obtain an optimal element size, stability analysis of overpressure, and validation study to evaluate the accuracy of the numerical results based on Unified Facilities Criteria (UFC) 3-340-02. A parametric analysis was performed using the validated numerical model to investigate the effects of the entrance shape and blast pockets on the reduction in the maximum overpressure. The maximum overpressures were effectively reduced as the slope angle of the tunnel entrance decreased and the length of the blast pocket divided by the tunnel width decreased. An optimized shape of the tunnel was proposed based on the numerical results, where the peak overpressures were reduced by a maximum of 64.5%. This study aims to protect facilities, personnel, and equipment and further reduce construction costs by lowering the overpressure rating of blast valves in protective tunnels.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (9) , 3912-3920
Modified Shielding Effectiveness Equation for Novel Multilayered Waveguide-Below-Cutoff Array
This paper presents an airflow analysis and a shielding effectiveness (SE) analysis for a multilayered waveguide-below-cutoff array (WBCA) used to prevent electromagnetic penetration. The performance of the conventional unit square WBCA and the multilayered WBCA is compared. For the airflow analysis, the simulations are performed at the entrance and exit of the shielding structure when an airflow velocity of 1 m/s is injected at the inlet. The velocity loss and pressure difference of the multilayered WBCA are improved compared with the unit square WBCA. In terms of the shielding, the SE of the multilayered WBCA is compensated by increasing the number of overlapping layers. Furthermore, a new SE equation is derived by modifying that of the unit square WBCA.
- 12 July 2018
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Microwave Theory and Techniques
- Vol. 66 (9) , 3912-3920
Modified Shielding Effectiveness Equation for Novel Multilayered Waveguide-Below-Cutoff Array
This paper presents an airflow analysis and a shielding effectiveness (SE) analysis for a multilayered waveguide-below-cutoff array (WBCA) used to prevent electromagnetic penetration. The performance of the conventional unit square WBCA and the multilayered WBCA is compared. For the airflow analysis, the simulations are performed at the entrance and exit of the shielding structure when an airflow velocity of 1 m/s is injected at the inlet. The velocity loss and pressure difference of the multilayered WBCA are improved compared with the unit square WBCA. In terms of the shielding, the SE of the multilayered WBCA is compensated by increasing the number of overlapping layers. Furthermore, a new SE equation is derived by modifying that of the unit square WBCA.
- Open Access
- 1 September 2016
- Published by Korea Society of Geothermal Energy Engineers in Transactions of the Korea Society of Geothermal Energy Engineers
- Vol. 12 (3) , 1-8
Evaluation of Air Flow Characteristics in accordance with Types of Waveguide-Below-Cutoff (WBC) Arrays and Their Shielding Effectiveness of Electromagnetic Pulse (EMP)
- 1 September 2016
- Published by Korea Society of Geothermal Energy Engineers in Transactions of the Korea Society of Geothermal Energy Engineers
- Vol. 12 (3) , 1-8
Open AccessEvaluation of Air Flow Characteristics in accordance with Types of Waveguide-Below-Cutoff (WBC) Arrays and Their Shielding Effectiveness of Electromagnetic Pulse (EMP)
- Open Access
- 1 March 2016
- Published by Korea Society of Geothermal Energy Engineers in Transactions of the Korea Society of Geothermal Energy Engineers
- Vol. 12 (1) , 1-6
Electromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity
Electromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity EMP;CFD;Waveguide;WBC Array;Shielding Effectiveness;Emergency Generator; Characteristics of exhaust from chimney of electricity generator are analyzed based on CFD when Waveguide-Below-Cutoff (WBC) array is installed in order to achieve the certain level of electromagnetic pulse (EMP) shielding. The main purpose is prediction of average and maximum velocity of exhaust. The results reveal that: 1) When the specification of waveguide is given as 80-diameter, 400-length, and the gap of 20 mm, the shielding effectiveness (SE) is 140dB. The average and maximum velocity of exhaust in the chimney with WBC Array can be represented as exponential functions. 2) As the number of WBC increases, the velocity in the chimney dwindles. 3) Under the situation that WBC with 80 mm diameter is located at intervals of 20 mm, the average velocity can be approximated by $25.5344{\times}e^{(-0.0098{\times}N_{WBC})}$ with input velocity of 15 m/s. In addition, the determination coefficient is 0.915, which is sufficiently high.- 1 March 2016
- Published by Korea Society of Geothermal Energy Engineers in Transactions of the Korea Society of Geothermal Energy Engineers
- Vol. 12 (1) , 1-6
Open AccessElectromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity
Electromagnetic Pulse (EMP) Shielding Effectiveness of Waveguide-Below-Cutoff (WBC) Arrays Installed in Generator Exhaust Chimney and its Effects on Gas Velocity EMP;CFD;Waveguide;WBC Array;Shielding Effectiveness;Emergency Generator; Characteristics of exhaust from chimney of electricity generator are analyzed based on CFD when Waveguide-Below-Cutoff (WBC) array is installed in order to achieve the certain level of electromagnetic pulse (EMP) shielding. The main purpose is prediction of average and maximum velocity of exhaust. The results reveal that: 1) When the specification of waveguide is given as 80-diameter, 400-length, and the gap of 20 mm, the shielding effectiveness (SE) is 140dB. The average and maximum velocity of exhaust in the chimney with WBC Array can be represented as exponential functions. 2) As the number of WBC increases, the velocity in the chimney dwindles. 3) Under the situation that WBC with 80 mm diameter is located at intervals of 20 mm, the average velocity can be approximated by $25.5344{\times}e^{(-0.0098{\times}N_{WBC})}$ with input velocity of 15 m/s. In addition, the determination coefficient is 0.915, which is sufficiently high.