Jose I. Padovani
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jose I. Padovani has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
- Ali M. Ibrahim
Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza 12613, Egypt
2 shared publications - Beth L. Pruitt
University of California Santa Barbara
2 shared publications - Roger T. Howe
Department of Electrical Engineering, Stanford University, Stanford, CA 94305, USA
2 shared publications - Stefanie S. Jeffrey
Department of Surgery, Stanford University School of Medicine, Stanford, USA
2 shared publications - Yasser H. Anis
Mechanical Design and Production Department, Faculty of Engineering, Cairo University, Giza, Egypt
2 shared publications B W Chui
Stanford University
1 shared publication
Latest Publications
- Open Access
- 21 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (6) , 590
Modeling of Droplet Generation in a Microfluidic Flow-Focusing Junction for Droplet Size Control
In this paper, we study the parameters that affect the generation of droplets in a microfluidic flow-focusing junction. Droplets are evaluated based on the size and frequency of generation. Droplet size control is essential for microfluidic lab-on-a-chip applications in biology, chemistry, and medicine. We developed a three-dimensional numerical model that can emulate the performance of the physical system. A numerical model can help design droplet-generation chips with new junction geometries, different dispersed and continuous phase types, and different flow rates. Our model uses a conservative level-set method (LSM) to track the interface between two immiscible fluids using a fixed mesh. Water was used for the dispersed phase and mineral oil for the continuous phase. The effects of the continuous-to-dispersed flow rate ratio () and the surfactant concentration on the droplet generation were studied both using the numerical model and experimentally. The numerical model was found to render results that are in good agreement with the experimental ones, which validates the LSM model. The validated numerical model was used to study the time effect of changing on the generated droplet size. Properly timing when the flow rates are changed enables control over the size of the next generated droplet, which is useful for single-droplet size modulation applications.- 21 May 2021
- Published by MDPI AG in Micromachines
- Vol. 12 (6) , 590
Open AccessModeling of Droplet Generation in a Microfluidic Flow-Focusing Junction for Droplet Size Control
In this paper, we study the parameters that affect the generation of droplets in a microfluidic flow-focusing junction. Droplets are evaluated based on the size and frequency of generation. Droplet size control is essential for microfluidic lab-on-a-chip applications in biology, chemistry, and medicine. We developed a three-dimensional numerical model that can emulate the performance of the physical system. A numerical model can help design droplet-generation chips with new junction geometries, different dispersed and continuous phase types, and different flow rates. Our model uses a conservative level-set method (LSM) to track the interface between two immiscible fluids using a fixed mesh. Water was used for the dispersed phase and mineral oil for the continuous phase. The effects of the continuous-to-dispersed flow rate ratio () and the surfactant concentration on the droplet generation were studied both using the numerical model and experimentally. The numerical model was found to render results that are in good agreement with the experimental ones, which validates the LSM model. The validated numerical model was used to study the time effect of changing on the generated droplet size. Properly timing when the flow rates are changed enables control over the size of the next generated droplet, which is useful for single-droplet size modulation applications. - 3 November 2020
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 24 (12) , 1-12
Electropermanent magnet-driven droplet size modulation for two-phase ferromicrofluidics
- 3 November 2020
- Published by Springer Nature in Microfluidics and Nanofluidics
- Vol. 24 (12) , 1-12
Electropermanent magnet-driven droplet size modulation for two-phase ferromicrofluidics
- 1 June 2016
- Published by World Scientific Pub Co Pte Ltd in TECHNOLOGY
- Vol. 04 (02) , 110-119
Electropermanent magnet actuation for droplet ferromicrofluidics
Droplet actuation is an essential mechanism for droplet-based microfluidic systems. On-demand electromagnetic actuation is used in a ferrofluid-based microfluidic system for water droplet displacement. Electropermanent magnets (EPMs) are used to induce 50 mT magnetic fields in a ferrofluid filled microchannel with gradients up to 6.4 × 104 kA/m2. Short 50 µs current pulses activate the electropermanent magnets and generate negative magnetophoretic forces that range from 10 to 70 nN on 40 to 80 µm water-in-ferrofluid droplets. Maximum droplet displacement velocities of up to 300 µm/s are obtained under flow and no-flow conditions. Electropermanent magnet-activated droplet sorting under continuous flow is demonstrated using a split-junction microfluidic design.
- 1 June 2016
- Published by World Scientific Pub Co Pte Ltd in TECHNOLOGY
- Vol. 04 (02) , 110-119
Electropermanent magnet actuation for droplet ferromicrofluidics
Droplet actuation is an essential mechanism for droplet-based microfluidic systems. On-demand electromagnetic actuation is used in a ferrofluid-based microfluidic system for water droplet displacement. Electropermanent magnets (EPMs) are used to induce 50 mT magnetic fields in a ferrofluid filled microchannel with gradients up to 6.4 × 104 kA/m2. Short 50 µs current pulses activate the electropermanent magnets and generate negative magnetophoretic forces that range from 10 to 70 nN on 40 to 80 µm water-in-ferrofluid droplets. Maximum droplet displacement velocities of up to 300 µm/s are obtained under flow and no-flow conditions. Electropermanent magnet-activated droplet sorting under continuous flow is demonstrated using a split-junction microfluidic design.
- 30 June 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 21 (8)
Patterned cracks improve yield in the release of compliant microdevices from silicon-on-insulator wafers
- 30 June 2011
- Published by IOP Publishing in Journal of Micromechanics and Microengineering
- Vol. 21 (8)
Patterned cracks improve yield in the release of compliant microdevices from silicon-on-insulator wafers
- 1 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-303
Patterned cracks in the buried oxide layer improve yield in device release from SOI wafers
Cracks patterned lithographically into the buried oxide (BOX) layer of silicon-on-insulator wafers were found to substantially improve yield in the release of ultrasoft silicon cantilevers. The BOX layer is useful as an etch stop and sacrificial layer in microfabrication. However, compressive stress in the BOX membrane can cause it to buckle and crack when released. These cracks can damage delicate structures in the device layer and reduce yield. Cracks were patterned into the BOX layer prior to avoid critical regions near or under devices; these patterned cracks reduced damage to devices from spontaneous cracks in the BOX layer and improved yield.
- 1 January 2011
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- p. 300-303
Patterned cracks in the buried oxide layer improve yield in device release from SOI wafers
Cracks patterned lithographically into the buried oxide (BOX) layer of silicon-on-insulator wafers were found to substantially improve yield in the release of ultrasoft silicon cantilevers. The BOX layer is useful as an etch stop and sacrificial layer in microfabrication. However, compressive stress in the BOX membrane can cause it to buckle and crack when released. These cracks can damage delicate structures in the device layer and reduce yield. Cracks were patterned into the BOX layer prior to avoid critical regions near or under devices; these patterned cracks reduced damage to devices from spontaneous cracks in the BOX layer and improved yield.