TRTruls Råmunddal

Truls Råmunddal

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Truls Råmunddal has a total of 39 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Predicting troponin biomarker elevation from electrocardiograms using a deep neural network

    by Lukas Hilgendorf, Petur Petursson, Vibha Gupta, Truls Ramunddal, Erik Andersson, Peter Lundgren, Christian Dworeck, Charlotta Ljungman, Jan Boren, Aidin Rawshani, et al.

    Background: Elevated troponin levels are a sensitive biomarker for cardiac injury. The quick and reliable prediction of troponin elevation for patients with chest pain from readily available ECGs may pose a valuable time-saving diagnostic tool during decision-making concerning this patient population. Methods and results: The data used included 15 856 ECGs from patients presenting to the emergency rooms with chest pain or dyspnoea at two centres in Sweden from 2015 to June 2023. All patients had high-sensitivity troponin test results within 6 hours after 12-lead ECG. Both troponin I (TnI) and TnT were used, with biomarker-specific cut-offs and sex-specific cut-offs for TnI. On this dataset, a residual convolutional neural network (ResNet) was trained 10 times, each on a unique split of the data. The final model achieved an average area under the curve for the receiver operating characteristic curve of 0.7717 (95% CI±0.0052), calibration curve analysis revealed a mean slope of 1.243 (95% CI±0.075) and intercept of −0.073 (95% CI±0.034), indicating a good correlation between prediction and ground truth. Post-classification, tuned for F1 score, accuracy was 71.43% (95% CI±1.28), with an F1 score of 0.5642 (95% CI±0.0052) and a negative predictive value of 0.8660 (95% CI±0.0048), respectively. The ResNet displayed comparable or surpassing metrics to prior presented models. Conclusion: The model exhibited clinically meaningful performance, notably its high negative predictive accuracy. Therefore, clinical use of comparable neural networks in first-line, quick-response triage of patients with chest pain or dyspnoea appears as a valuable option in future medical practice.


  • Open Access

    Safety and Feasibility Using a Fluid-Filled Wire to Avoid Hydrostatic Errors in Physiological Intracoronary Measurements

    by Truls Råmunddal, Christian Dworeck, Petronella Torild, Sofie Andréen, Li-Ming Gan, Geir Hirlekar, Dan Ioanes, Anna Myredal, Jacob Odenstedt, Petur Petursson, et al.

    Background. Using a fluid-filled wire with a pressure sensor outside the patient compared to a conventional pressure wire may avoid the systematic error introduced by the hydrostatic pressure within the coronary circulation. Aims. To assess the safety and effectiveness of the novel fluid-filled wire, Wirecath (Cavis Technologies, Uppsala, Sweden), as well as its ability to avoid the hydrostatic pressure error. Methods and Results. The Wirecath pressure wire was used in 45 eligible patients who underwent invasive coronary angiography and had a clinical indication for invasive coronary pressure measurement at Sahlgrenska University Hospital, Gothenburg, Sweden. In 29 patients, a simultaneous measurement was performed with a conventional coronary pressure wire (PressureWire X, Abbott Medical, Plymouth, MN, USA), and in 19 patients, the vertical height difference between the tip of the guide catheter and the wire measure point was measured in a 90-degree lateral angiographic projection. No adverse events caused by the pressure wires were reported. The mean Pd/Pa and mean FFR using the fluid-filled wire and the sensor-tipped wire differed significantly; however, after correcting for the hydrostatic effect, the sensor-tipped wire pressure correlated well with the fluid-filled wire pressure (R=0.74 vs. R=0.89 at rest and R=0.89 vs. R=0.98 at hyperemia). Conclusion. Hydrostatic errors in physiologic measurements can be avoided by using the fluid-filled Wirecath wire, which was safe to use in the present study. This trial is registered with NCT04776577 and NCT04802681.

  • Open Access

    Impact of thrombus aspiration during ST-Elevation Myocardial Infarction: a six month composite endpoint and risk of stroke analyses of the TASTE trial

    by Göran K Olivecrona, Bo Lagerqvist, Ole Fröbert, Thórarinn Gudnason, Michael Maeng, Truls Råmunddal, Jan Haupt, Thomas Kellerth, Jason Stewart, Giovanna Sarno, et al.

    Routine thrombus aspiration during primary percutaneous coronary intervention (PCI) in ST-elevation myocardial infarction (STEMI) did not reduce the primary composite endpoint in the “A Randomised Trial of Routine Aspiration ThrOmbecTomy With PCI Versus PCI ALone in Patients With STEMI Undergoing Primary PCI” (TOTAL) trial. We aimed to analyse a similar endpoint in “The Thrombus Aspiration in ST-Elevation myocardial infarction in Scandinavia” (TASTE) trial up to 180 days. In TASTE, 7244 patients with STEMI were randomised to thrombus aspiration followed by PCI or to PCI alone. We analysed the quadruple composite endpoint of cardiovascular death, cardiogenic shock, rehospitalisation for myocardial infarction, or new hospitalisation for heart failure. Furthermore, an extended net-benefit composite endpoint including stent thrombosis, target vessel revascularization or stroke within 180 days was analysed. The primary quadruple composite endpoint occurred in 8.7 % (316 of 3621) in the thrombus aspiration group compared to 9.3 % (338 of 3623) in the PCI alone group (hazard ratio (HR), 0.93; 95 % confidence interval (CI); 0.80 - 1.09, P = 0.36) and the extended net-benefit composite endpoint in 12.0 % (436) vs. 13.2 % (479) (HR, 0.90; 95 % CI; 0.79 - 1.03, P = 0.12). Stroke within 30 days occurred in 0.7 % (27) vs. 0.7 % (24) (HR, 0.89; 95 % CI; 0.51–1.54, P = 0.68). A large and an extended composite endpoint analysis from the TASTE trial did not demonstrate any clinical benefit of routine thrombus aspiration during PCI in patients with STEMI. There was no evidence of an increased risk of stroke with thrombus aspiration.