Ágnes Orbán
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ágnes Orbán has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
Adam Butykai
Department of Physics, Budapest University of Technology and Economics and MTA-BME Lendület Magneto-optical Spectroscopy Research Group, 1111 Budapest, Hungary
1 shared publication- Inês S. Albuquerque
Instituto de Medicina Molecular, Faculdade de Medicina, Universidade de Lisboa, Avenida Professor Egas Moniz, 1649-028 Lisboa, Portugal
1 shared publication István Kézsmárki
Department of Physics, Budapest University of Technology and Economics and MTA-BME Lendület Magneto-optical Spectroscopy Research Group, 1111 Budapest, Hungary
1 shared publication- Maria Rebelo
Instituto de Medicina Molecular, Faculdade de Medicina, Lisbon, Portugal
1 shared publication Petra Molnár
Department of Physics, Budapest University of Technology and Economics and MTA-BME Lendület Magneto-optical Spectroscopy Research Group, 1111 Budapest, Hungary
1 shared publication
Latest Publications
- Open Access
- 17 March 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 23218
Efficient monitoring of the blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method
Intense research efforts have been focused on the improvement of the efficiency and sensitivity of malaria diagnostics, especially in resource-limited settings for the detection of asymptomatic infections. Our recently developed magneto-optical (MO) method allows the accurate quantification of malaria pigment crystals (hemozoin) in blood by their magnetically induced rotation. First evaluations of the method using β-hematin crystals and in vitro P. falciparum cultures implied its potential for high-sensitivity malaria diagnosis. To further investigate this potential, here we study the performance of the method in monitoring the in vivo onset and progression of the blood-stage infection in a rodent malaria model. Our results show that the MO method can detect the first generation of intraerythrocytic P. berghei parasites 66–76 hours after sporozoite injection, demonstrating similar sensitivity to Giesma-stained light microscopy and exceeding that of flow cytometric techniques. Magneto-optical measurements performed during and after the treatment of P. berghei infections revealed that both the follow up under treatment and the detection of later reinfections are feasible with this new technique. The present study demonstrates that the MO method – besides being label and reagent-free, automated and rapid – has a high in vivo sensitivity and is ready for in-field evaluation.
- 17 March 2016
- Published by Springer Nature in Scientific Reports
- Vol. 6 (1) , 23218
Open AccessEfficient monitoring of the blood-stage infection in a malaria rodent model by the rotating-crystal magneto-optical method
Intense research efforts have been focused on the improvement of the efficiency and sensitivity of malaria diagnostics, especially in resource-limited settings for the detection of asymptomatic infections. Our recently developed magneto-optical (MO) method allows the accurate quantification of malaria pigment crystals (hemozoin) in blood by their magnetically induced rotation. First evaluations of the method using β-hematin crystals and in vitro P. falciparum cultures implied its potential for high-sensitivity malaria diagnosis. To further investigate this potential, here we study the performance of the method in monitoring the in vivo onset and progression of the blood-stage infection in a rodent malaria model. Our results show that the MO method can detect the first generation of intraerythrocytic P. berghei parasites 66–76 hours after sporozoite injection, demonstrating similar sensitivity to Giesma-stained light microscopy and exceeding that of flow cytometric techniques. Magneto-optical measurements performed during and after the treatment of P. berghei infections revealed that both the follow up under treatment and the detection of later reinfections are feasible with this new technique. The present study demonstrates that the MO method – besides being label and reagent-free, automated and rapid – has a high in vivo sensitivity and is ready for in-field evaluation.