YOYu. N. Odarenko

Yu. N. Odarenko

*This is an algorithmically generated author record based on publicly available information.

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Yu. N. Odarenko has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • L. S. Barbarash

    Federal State Budgetary Institution "Research Institute for Complex Issues of Cardiovascular Diseases"; State Budgetary Healthcare Institution of the Kemerovo Region "Kemerovo Regional Clinical Cardiology Dispensary n.a. Academician L.S. Barbarash"

    2 shared publications
  • N. V. Rutkovskaya

    Federal State Budgetary Institution "Research Institute for Complex Issues of Cardiovascular Diseases"; State Budgetary Healthcare Institution of the Kemerovo Region "Kemerovo Regional Clinical Cardiology Dispensary n.a. Academician L.S. Barbarash"

    2 shared publications
  • S. G. Kokorin

    Federal State Budgetary Institution "Research Institute for Complex Issues of Cardiovascular Diseases"

    2 shared publications
  • A. N. Stasev

    Федеральное государственное бюджетное научное учреждение «Научно-исследовательский институт комплексных проблем сердечно-сосудистых заболеваний

    1 shared publication
  • Alexander N. Stasev

    Research Institute for Complex Issues of Cardiovascular Diseases, Kemerovo

    1 shared publication
  • E. A. Khomenko

    Federal State Budgetary Institution "Research Institute for Complex Issues of Cardiovascular Diseases"; State Budgetary Healthcare Institution of the Kemerovo Region "Kemerovo Regional Clinical Cardiology Dispensary n.a. Academician L.S. Barbarash"

    1 shared publication

Latest Publications

  • Open Access

    THE USE OF TISSUE PROSTHESIS FOR MITRAL VALVE REPLACEMENT: POSSIBILITY OF DISCONTINUATION OF ANTICOAGULATION

    by Yu. N. Odarenko, N. V. Rutkovskaya, E. V. Gorbunova, E. A. Khomenko, S. G. Kokorin, L. S. Barbarash

    Aim. To evaluate the clinical efficacy of gradual sinus rhythm restoration, including the bioprosthetic mitral valve replacement combined with maze radiofrequency ablation, external cardioversion and catheter ablation.Methods.102 medical records of patients with mitral valve disease and long-standing atrial fibrillation (4,7±2,7 years) were restrospectively reviewed. Maze procedure was performed under extracorporeal circulation before the mitral valve replacement. The endpoints were monitored at the day of surgery, at discharge, and 3, 6 and 12 months after surgery.Results.Sinus rhythm was recorded in 65.7% of patients at discharge from the hospital. The completeness of the follow-up was 80.4%. Steady regular rhythm was maintained in 64.6 % of patients in the study group. Other patients (35.4%) underwent cardioversion with the efficacy rate of 41.4%. Anticoagulation therapy was withdrawn in 65.9% of patients three months after surgery. 18.3% of patients with symptomatic arrhythmia underwent catheter ablation, which allowed to restore sinus rhythm in 73.3% of cases. Sinus rhythm was recorded in 92.7% of cases within the 1-year follow-up. Importantly, 79.3% of patients were discontinued of indirect anticoagulants.Conclusion.Discontinuation of indirect anticoagulants proved its beneficial effects and safety on the restoration of sinus rhythm in patients after bioprosthetic mitral valve replacement.


  • Open Access

    IMMEDIATE AND LONG-TERM OUTCOMES AFTER BIOPROSTHETIC MITRAL VALVE REPLACEMENT WITH THE PRESERVATION OF THE SUBVALVULAR APPARATUS

    by Yu. N. Odarenko, N. V. Rutkovskaya, S. G. Kokorin, A. N. Stasev, L. S. Barbarash

    Aim. To assess the immediate and long-term outcomes after bioprosthetic mitral valve replacement with the preservation of the subvalvular apparatus. Methods. 304 patients who underwent primary bioprosthetic mitral valve replacement in the period from 2001 to 2009 were included in the study. Patients were enrolled into two groups with either preserved subvalvular structures (Group 1. n = 142, 47%) or resected structures (Group 2, n = 162) during bioprosthetic mitral valve replacement. For the unbiased assessment of the efficiency of valve-preserving approach, randomly selected patients from Group 1 (n = 75) and Group 2 (n = 40) underwent preoperative and postoperative invasive monitoring of the central hemodynamics using the Swan-Ganz thermodilution catheter. Results In-hospital mortality was 1.4% (n = 2) in Group 1 and 4.3% in Group 2. The most common cause of death was acute left ventricular failure. We found that the preservation of subvalvular structures allows ensuring the optimal linear and volumetric echocardiography parameters in the immediate postoperative period, despite the hemodynamic profile of the defect. However, the positive effects were more pronounced in patients with more severe mitral regurgitation. Patients with preserved subvalvular structures had more durable surgical mitral valve replacement according to the echocardiographic findings in the long-term period. The invasive monitoring of central hemodynamics allowed determining that total subvalvular apparatus preservation was associated with more significant pressure decline in the pulmonary circulation (mean pulmonary arterial pressure and pulmonary capillary wedge pressure) and improved cardiac index and output. Posterior leaflet preservation was associated with less pronounced changes and patients who underwent routine mitral valve replacement had the worst intermediate outcomes. Conclusion The results of the presented study suggest that the preservation of subvalvular apparatus, unless otherwise indicated, is associated with improved immediate and long-term outcomes after mitral valve replacement.

  • Open Access

    Prosthetic heart valve selection in women of childbearing age with acquired heart disease: a case report

    by Leonid Barbarash, Natalya Rutkovskaya, Olga Barbarash, Yuri Odarenko, Alexander Stasev, Evgenya Uchasova

    The problem of prosthetic heart valve selection in fertile women with acquired heart defects remains crucial in modern cardiology. Mechanical heart valves require lifelong indirect anticoagulant therapy, which has significant fetal toxicity and is unacceptable for women planning pregnancy. Bioprosthetic heart valves are the best choice for fertile women; however, their durability is limited, and reoperations are required. We describe the clinical case of a 21-year-old Russian woman with infectious endocarditis who underwent heart valve replacement with an epoxy-treated mitral valve prosthesis. Epoxy-treated bioprosthetic heart valves can be used without long-term anticoagulant therapy because of their optimal hemodynamic functional parameters. Moreover, their high thromboresistance and resistance to infection improve patients’ quality of life in their late postoperative period. We recommend these valves both in older persons and in young patients including women who are planning pregnancy.