PWP. Sean Walsh

P. Sean Walsh

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


P. Sean Walsh has a total of 53 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Maximizing Small Biopsy Patient Samples: Unified RNA-Seq Platform Assessment of over 120,000 Patient Biopsies

    by P. Sean Walsh, Yangyang Hao, Jie Ding, Jianghan Qu, Jonathan Wilde, Ruochen Jiang, Richard T. Kloos, Jing Huang, Giulia C. Kennedy

    Despite its wide-ranging benefits, whole-transcriptome or RNA exome profiling is challenging to implement in a clinical diagnostic setting. The Unified Assay is a comprehensive workflow wherein exome-enriched RNA-sequencing (RNA-Seq) assays are performed on clinical samples and analyzed by a series of advanced machine learning-based classifiers. Gene expression signatures and rare and/or novel genomic events, including fusions, mitochondrial variants, and loss of heterozygosity were assessed using RNA-Seq data generated from 120,313 clinical samples across three clinical indications (thyroid cancer, lung cancer, and interstitial lung disease). Since its implementation, the data derived from the Unified Assay have allowed significantly more patients to avoid unnecessary diagnostic surgery and have played an important role in guiding follow-up decisions regarding treatment. Collectively, data from the Unified Assay show the utility of RNA-Seq and RNA expression signatures in the clinical laboratory, and their importance to the future of precision medicine.


  • Open Access

    Improving lung cancer risk stratification leveraging whole transcriptome RNA sequencing and machine learning across multiple cohorts

    by Yoonha Choi, Jianghan Qu, Shuyang Wu, Yangyang Hao, Jiarui Zhang, Jianchang Ning, Xinwu Yang, Lori Lofaro, Daniel G. Pankratz, Joshua Babiarz, et al.

    Background: Bronchoscopy for suspected lung cancer has low diagnostic sensitivity, rendering many inconclusive results. The Bronchial Genomic Classifier (BGC) was developed to help with patient management by identifying those with low risk of lung cancer when bronchoscopy is inconclusive. The BGC was trained and validated on patients in the Airway Epithelial Gene Expression in the Diagnosis of Lung Cancer (AEGIS) trials. A modern patient cohort, the BGC Registry, showed differences in key clinical factors from the AEGIS cohorts, with less smoking history, smaller nodules and older age. Additionally, we discovered interfering factors (inhaled medication and sample collection timing) that impacted gene expressions and potentially disguised genomic cancer signals. Methods: In this study, we leveraged multiple cohorts and next generation sequencing technology to develop a robust Genomic Sequencing Classifier (GSC). To address demographic composition shift and interfering factors, we synergized three algorithmic strategies: 1) ensemble of clinical dominant and genomic dominant models; 2) development of hierarchical regression models where the main effects from clinical variables were regressed out prior to the genomic impact being fitted in the model; and 3) targeted placement of genomic and clinical interaction terms to stabilize the effect of interfering factors. The final GSC model uses 1232 genes and four clinical covariates – age, pack-years, inhaled medication use, and specimen collection timing. Results: In the validation set (N = 412), the GSC down-classified low and intermediate pre-test risk subjects to very low and low post-test risk with a specificity of 45% (95% CI 37–53%) and a sensitivity of 91% (95%CI 81–97%), resulting in a negative predictive value of 95% (95% CI 89–98%). Twelve percent of intermediate pre-test risk subjects were up-classified to high post-test risk with a positive predictive value of 65% (95%CI 44–82%), and 27% of high pre-test risk subjects were up-classified to very high post-test risk with a positive predictive value of 91% (95% CI 78–97%). Conclusions: The GSC overcame the impact of interfering factors and achieved consistent performance across multiple cohorts. It demonstrated diagnostic accuracy in both down- and up-classification of cancer risk, providing physicians actionable information for many patients with inconclusive bronchoscopy.


  • Open Access

    Analytical Verification Performance of Afirma Genomic Sequencing Classifier in the Diagnosis of Cytologically Indeterminate Thyroid Nodules

    by Yangyang Hao, Yoonha Choi, Joshua E. Babiarz, Richard T. Kloos, Giulia C. Kennedy, Jing Huang, P. Sean Walsh

    Background: Fine needle aspiration (FNA) cytology, a diagnostic test central to thyroid nodule management, may yield indeterminate results in up to 30% of cases. The Afirma® Genomic Sequencing Classifier (GSC) was developed and clinically validated to utilize genomic material obtained during the FNA to accurately identify benign nodules among those deemed cytologically indeterminate so that diagnostic surgery can be avoided. A key question for diagnostic tests is their robustness under different perturbations that may occur in the lab. Herein, we describe the analytical performance of the Afirma GSC. Results: We examined the analytical sensitivity of the Afirma GSC to varied input RNA amounts and the limit of detection of malignant signals with heterogenous samples mixed with adjacent normal or benign tissues. We also evaluated the analytical specificity from potential interfering substances such as blood and genomic DNA. Further, the inter-laboratory, intra-run, and inter-run reproducibility of the assay were examined. Analytical sensitivity analysis showed that Afirma GSC calls are tolerant to variation in RNA input amount (5–30 ng), and up to 75% dilution of malignant FNA material. Analytical specificity studies demonstrated Afirma GSC remains accurate in presence of up to 75% blood or 30% genomic DNA. The Afirma GSC results are highly reproducible across different operators, runs, reagent lots, and laboratories. Conclusion: The analytical robustness and reproducibility of the Afirma GSC test support its routine clinical use among thyroid nodules with indeterminant FNA cytology.


  • Open Access

    Identification of Hürthle cell cancers: solving a clinical challenge with genomic sequencing and a trio of machine learning algorithms

    by Yangyang Hao, Quan-Yang Duh, Richard T. Kloos, Joshua Babiarz, R. Mack Harrell, S. Thomas Traweek, Su Yeon Kim, Grazyna Fedorowicz, P. Sean Walsh, Peter M. Sadow, et al.

    Identification of Hürthle cell cancers by non-operative fine-needle aspiration biopsy (FNAB) of thyroid nodules is challenging. Resultingly, non-cancerous Hürthle lesions were conventionally distinguished from Hürthle cell cancers by histopathological examination of tissue following surgical resection. Reliance on histopathological evaluation requires patients to undergo surgery to obtain a diagnosis despite most being non-cancerous. It is highly desirable to avoid surgery and to provide accurate classification of benignity versus malignancy from FNAB preoperatively. In our first-generation algorithm, Gene Expression Classifier (GEC), we achieved this goal by using machine learning (ML) on gene expression features. The classifier is sensitive, but not specific due in part to the presence of non-neoplastic benign Hürthle cells in many FNAB. We sought to overcome this low-specificity limitation by expanding the feature set for ML using next-generation whole transcriptome RNA sequencing and called the improved algorithm the Genomic Sequencing Classifier (GSC). The Hürthle identification leverages mitochondrial expression and we developed novel feature extraction mechanisms to measure chromosomal and genomic level loss-of-heterozygosity (LOH) for the algorithm. Additionally, we developed a multi-layered system of cascading classifiers to sequentially triage Hürthle cell-containing FNAB, including: 1. presence of Hürthle cells, 2. presence of neoplastic Hürthle cells, and 3. presence of benign Hürthle cells. The final Hürthle cell Index utilizes 1048 nuclear and mitochondrial genes; and Hürthle cell Neoplasm Index leverages LOH features as well as 2041 genes. Both indices are Support Vector Machine (SVM) based. The third classifier, the GSC Benign/Suspicious classifier, utilizes 1115 core genes and is an ensemble classifier incorporating 12 individual models. The accurate algorithmic depiction of this complex biological system among Hürthle subtypes results in a dramatic improvement of classification performance; specificity among Hürthle cell neoplasms increases from 11.8% with the GEC to 58.8% with the GSC, while maintaining the same sensitivity of 89%.


  • Open Access

    Analytical performance of a bronchial genomic classifier

    by Zhanzhi Hu, Duncan Whitney, Jessica R. Anderson, Manqiu Cao, Christine Ho, Yoonha Choi, Jing Huang, Robert Frink, Kate Porta Smith, Robert Monroe, et al.

    The current standard practice of lung lesion diagnosis often leads to inconclusive results, requiring additional diagnostic follow up procedures that are invasive and often unnecessary due to the high benign rate in such lesions (Chest 143:e78S-e92, 2013). The Percepta bronchial genomic classifier was developed and clinically validated to provide more accurate classification of lung nodules and lesions that are inconclusive by bronchoscopy, using bronchial brushing specimens (N Engl J Med 373:243–51, 2015, BMC Med Genomics 8:18, 2015). The analytical performance of the Percepta test is reported here. Analytical performance studies were designed to characterize the stability of RNA in bronchial brushing specimens during collection and shipment; analytical sensitivity defined as input RNA mass; analytical specificity (i.e. potentially interfering substances) as tested on blood and genomic DNA; and assay performance studies including intra-run, inter-run, and inter-laboratory reproducibility. RNA content within bronchial brushing specimens preserved in RNAprotect is stable for up to 20 days at 4 °C with no changes in RNA yield or integrity. Analytical sensitivity studies demonstrated tolerance to variation in RNA input (157 ng to 243 ng). Analytical specificity studies utilizing cancer positive and cancer negative samples mixed with either blood (up to 10 % input mass) or genomic DNA (up to 10 % input mass) demonstrated no assay interference. The test is reproducible from RNA extraction through to Percepta test result, including variation across operators, runs, reagent lots, and laboratories (standard deviation of 0.26 for scores on > 6 unit scale). Analytical sensitivity, analytical specificity and robustness of the Percepta test were successfully verified, supporting its suitability for clinical use.


  • Analytical Performance Verification of a Molecular Diagnostic for Cytology-Indeterminate Thyroid Nodules

    by P. Sean Walsh, Jonathan I. Wilde, Edward Y. Tom, Jessica D. Reynolds, Daphne C. Chen, Darya I. Chudova, Moraima Pagan, Daniel G. Pankratz, Mei Wong, James Veitch, et al.

    Our objective was to verify the analytical performance of the Afirma gene expression classifier (GEC) in the classification of cytologically indeterminate thyroid nodule fine-needle aspirates (FNAs). Analytical performance studies were designed to characterize the stability of RNA in FNAs during collection and shipment, analytical sensitivity as applied to input RNA concentration and malignant/benign FNA mixtures, analytical specificity (i.e. potentially interfering substances) as tested on blood and genomic DNA, and assay performance studies including intra-nodule, intraassay, inter-assay, and inter-laboratory reproducibility. RNA content within FNAs preserved in FNAProtect is stable for up to 6 d at room temperature with no changes in RNA yield (P = 0.58) or quality (P = 0.56). FNA storage and shipping temperatures were found to have no significant effect on GEC scores (P = 0.55) or calls (100% concordance). Analytical sensitivity studies demonstrated tolerance to variation in RNA input (5-25 ng) and to the dilution of malignant FNA material down to 20%. Analytical specificity studies using malignant samples mixed with blood (up to 83%) and genomic DNA (up to 30%) demonstrated negligible assay interference with respect to false-negative calls, although benign FNA samples mixed with relatively high proportions of blood demonstrated a potential for false-positive calls. The test is reproducible from extraction through GEC result, including variation across operators, runs, reagent lots, and laboratories (sd of 0.158 for scores on a >6 unit scale). Analytical sensitivity, analytical specificity, robustness, and quality control of the GEC were successfully verified, indicating its suitability for clinical use.