Josiah Sliz
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Josiah Sliz has a total of 87 co-authors. Here are the top co-authors by number of shared publications:
- Geraldine A. Hamilton
Emulate, Inc
3 shared publications - Anna Herland
KTH Royal Institute of Technology
2 shared publications - Christopher D. Hinojosa
Emulate Inc., 27 Drydock Avenue, 5th Floor, Boston, MA, 02210, USA
2 shared publications - Donald Elliot Ingber
Wyss Institute for Biologically Inspired Engineering, Harvard University, Boston, MA, USA
2 shared publications - Katia Karalis
Emulate Inc
2 shared publications - Kyung-Jin Jang
Emulate Inc., 27 Drydock Avenue, Boston, MA 02210, USA
2 shared publications
Latest Publications
- Open Access
“A novel Organ-Chip system emulates three-dimensional architecture of the human epithelia and allows fine control of mechanical forces acting on it.”
Successful translation of in vivo experimental data to human patients is an unmet need and a bottleneck in the development of effective therapeutics. micro technology aims to address this need with significant advancements reported recently that enable modeling of organ level function. These microengineered chips enable researcher to recreate critical elements such as in vivo relevant tissue-tissue interface, air-liquid interface, and mechanical forces, such as mechanical stretch and fluidic shear stress, are crucial in emulating tissue level functions. Here, we present the development of a new, comprehensive 3D cell-culture system, where we combined our proprietary Organ-Chip technology with recent advantages in three-dimensional organotypic culture. Leveraging microfabrication techniques, we engineered a flexible chip that consists of a channel containing an organotypic epithelium surrounded by two vacuum channels that can be actuated to stretch the hydrogel throughout its thickness. Furthermore, the ceiling of this channel is a removable lid with a built-in microchannel that can be perfused with liquid or air and removed as needed for direct access to the tissue. The floor of this channel is a porous flexible membrane in contact with a microfluidic channel that provides diffusive mass transport to and from the channel. This additional microfluidic channel can be coated with endothelial cells to emulate a blood vessel and capture endothelial interactions. Our results show that the Open-Top Chip design successfully addresses common challenges associated with the Organs-on-Chips technology, including the capability to incorporate a tissue-specific extracellular matrix gel seeded with primary stromal cells, to reproduce the architectural complexity of tissues by micropatterning the gel, that can be extracted for H&E staining. We provide proof-of-concept data on the feasibility of the system using skin and alveolar epithelial primary cells and by simulating alveolar inflammation.
Open Access“A novel Organ-Chip system emulates three-dimensional architecture of the human epithelia and allows fine control of mechanical forces acting on it.”
Successful translation of in vivo experimental data to human patients is an unmet need and a bottleneck in the development of effective therapeutics. micro technology aims to address this need with significant advancements reported recently that enable modeling of organ level function. These microengineered chips enable researcher to recreate critical elements such as in vivo relevant tissue-tissue interface, air-liquid interface, and mechanical forces, such as mechanical stretch and fluidic shear stress, are crucial in emulating tissue level functions. Here, we present the development of a new, comprehensive 3D cell-culture system, where we combined our proprietary Organ-Chip technology with recent advantages in three-dimensional organotypic culture. Leveraging microfabrication techniques, we engineered a flexible chip that consists of a channel containing an organotypic epithelium surrounded by two vacuum channels that can be actuated to stretch the hydrogel throughout its thickness. Furthermore, the ceiling of this channel is a removable lid with a built-in microchannel that can be perfused with liquid or air and removed as needed for direct access to the tissue. The floor of this channel is a porous flexible membrane in contact with a microfluidic channel that provides diffusive mass transport to and from the channel. This additional microfluidic channel can be coated with endothelial cells to emulate a blood vessel and capture endothelial interactions. Our results show that the Open-Top Chip design successfully addresses common challenges associated with the Organs-on-Chips technology, including the capability to incorporate a tissue-specific extracellular matrix gel seeded with primary stromal cells, to reproduce the architectural complexity of tissues by micropatterning the gel, that can be extracted for H&E staining. We provide proof-of-concept data on the feasibility of the system using skin and alveolar epithelial primary cells and by simulating alveolar inflammation.
- Open Access
Liver-Chip: Reproducing Human and Cross-Species Toxicities
Nonclinical rodent and non-rodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans contributing to drug failures in the clinic. Here we applied microengineered Organ-on-Chip (Organ-Chip) technology to design rat, dog, and human Liver-Chips containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chips detected diverse phenotypes of liver toxicity including hepatocellular injury, steatosis, cholestasis, and fibrosis as well as species-specific toxicities when treated with tool compounds. Multi-species Liver-Chips may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk. One Sentence Summary: Microengineered Organ-Chip technology has been used to design rat, dog and human Liver-Chips that recapitulate species-specific liver toxicities.
Open AccessLiver-Chip: Reproducing Human and Cross-Species Toxicities
Nonclinical rodent and non-rodent toxicity models used to support clinical trials of candidate drugs may produce discordant results or fail to predict complications in humans contributing to drug failures in the clinic. Here we applied microengineered Organ-on-Chip (Organ-Chip) technology to design rat, dog, and human Liver-Chips containing species-specific primary hepatocytes interfaced with liver sinusoidal endothelial cells, with or without Kupffer cells and hepatic stellate cells, cultured under physiological fluid flow. The Liver-Chips detected diverse phenotypes of liver toxicity including hepatocellular injury, steatosis, cholestasis, and fibrosis as well as species-specific toxicities when treated with tool compounds. Multi-species Liver-Chips may provide a useful platform for prediction of liver toxicity and inform human relevance of liver toxicities detected in animal studies to better determine safety and human risk. One Sentence Summary: Microengineered Organ-Chip technology has been used to design rat, dog and human Liver-Chips that recapitulate species-specific liver toxicities.
- Open Access
A robotic platform for fluidically-linked human body-on-chips experimentation
Here we describe of an ‘Interrogator’ instrument that uses liquid-handling robotics, a custom software package, and an integrated mobile microscope to enable automated culture, perfusion, medium addition, fluidic linking, sample collection, and in situ microscopic imaging of up to 10 Organ Chips inside a standard tissue culture incubator. The automated Interrogator platform maintained the viability and organ-specific functions of 8 different vascularized, 2-channel, Organ Chips (intestine, liver, kidney, heart, lung, skin, blood-brain barrier (BBB), and brain) for 3 weeks in culture when fluidically coupled through their endothelium-lined vascular channels using a common blood substitute medium. When an inulin tracer was perfused through the multi-organ Human Body-on-Chips (HuBoC) fluidic network, quantitative distributions of this tracer could be accurately predicted using a physiologically-based multi-compartmental reduced order (MCRO) in silico model of the experimental system derived from first principles. This automated culture platform enables non-invasive imaging of cells within human Organ Chips and repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling, which should facilitate future HuBoc studies and pharmacokinetics (PK) analysis in vitr o.
Open AccessA robotic platform for fluidically-linked human body-on-chips experimentation
Here we describe of an ‘Interrogator’ instrument that uses liquid-handling robotics, a custom software package, and an integrated mobile microscope to enable automated culture, perfusion, medium addition, fluidic linking, sample collection, and in situ microscopic imaging of up to 10 Organ Chips inside a standard tissue culture incubator. The automated Interrogator platform maintained the viability and organ-specific functions of 8 different vascularized, 2-channel, Organ Chips (intestine, liver, kidney, heart, lung, skin, blood-brain barrier (BBB), and brain) for 3 weeks in culture when fluidically coupled through their endothelium-lined vascular channels using a common blood substitute medium. When an inulin tracer was perfused through the multi-organ Human Body-on-Chips (HuBoC) fluidic network, quantitative distributions of this tracer could be accurately predicted using a physiologically-based multi-compartmental reduced order (MCRO) in silico model of the experimental system derived from first principles. This automated culture platform enables non-invasive imaging of cells within human Organ Chips and repeated sampling of both the vascular and interstitial compartments without compromising fluidic coupling, which should facilitate future HuBoc studies and pharmacokinetics (PK) analysis in vitr o.