Thomas Krings
Research Subjects
Thomas Krings has a total of 49 co-authors. Here are the top co-authors by number of shared publications:
- Carsten Killer
Max Planck Institute for Plasma Physics, Wendelsteinstr. 1, 17491 Greifswald, Germany
2 shared publications - G. Satheeswaran
Forschungszentrum Jülich 3 , IEK-4 Plasmaphysik, Jülich 52428, Germany
2 shared publications - Philipp Drews
Plasma Physics, Fz Juelich IEK-4, Juelich, GERMANY
2 shared publications A Czarnecka
Institute of Plasma Physics and Laser Microfusion, Hery 23, 01-497 Warsaw, Poland
1 shared publicationA. Hiller
Forschungszentrum Jülich GmbH, Institut für Energie-und Klimaforschung-Plasmaphysik, Partner of the Trilateral Cluster (TEC), 52425 Jülich, Germany
1 shared publicationA. Knieps
Forschungszentrum Jülich GmbH, Institut für Energie-und Klimaforschung-Plasmaphysik, Partner of the Trilateral Cluster (TEC), 52425 Jülich, Germany
1 shared publication
Latest Publications
- Open Access
- 1 January 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (1) , 015305
Interface formation and Schottky barrier height for Y, Nb, Au, and Pt on Ge as determined by hard x-ray photoelectron spectroscopy
Development of a robust, thin, hole-blocking (n+) contact on high purity germanium (HPGe) has been the main challenge in the development of Ge-based radiation sensors. Yttrium has been reported to be a viable hole-blocking contact on HPGe, and detectors with low leakage have been fabricated. Niobium has also been considered as a potential hole-blocking contact due to its low work function. Here, we investigate interface chemistry and the Schottky barrier height of Y and Nb, as well as electron-blocking contacts Au and Pt, on Ge(100) surfaces using hard x-ray photoelectron spectroscopy. We find a barrier height of 1.05 ± 0.10 eV for Y/HPGe, confirming the formation of a hole-blocking barrier. For Nb/HPGe, the barrier height of 0.13 ± 0.10 eV demonstrates that the interface is not hole-blocking. The Schottky barrier of Au and Pt was found to be 0.45 ± 0.10 and 0.51 ± 0.10 eV, respectively.
- 1 January 2023
- Published by AIP Publishing in AIP Advances
- Vol. 13 (1) , 015305
Open AccessInterface formation and Schottky barrier height for Y, Nb, Au, and Pt on Ge as determined by hard x-ray photoelectron spectroscopy
Development of a robust, thin, hole-blocking (n+) contact on high purity germanium (HPGe) has been the main challenge in the development of Ge-based radiation sensors. Yttrium has been reported to be a viable hole-blocking contact on HPGe, and detectors with low leakage have been fabricated. Niobium has also been considered as a potential hole-blocking contact due to its low work function. Here, we investigate interface chemistry and the Schottky barrier height of Y and Nb, as well as electron-blocking contacts Au and Pt, on Ge(100) surfaces using hard x-ray photoelectron spectroscopy. We find a barrier height of 1.05 ± 0.10 eV for Y/HPGe, confirming the formation of a hole-blocking barrier. For Nb/HPGe, the barrier height of 0.13 ± 0.10 eV demonstrates that the interface is not hole-blocking. The Schottky barrier of Au and Pt was found to be 0.45 ± 0.10 and 0.51 ± 0.10 eV, respectively.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 033502
A new multi-channel Mach probe measuring the radial ion flow velocity profile in the boundary plasma of the W7-X stellarator
Ion flow velocity measurement in the edge and scraper-off layer region is beneficial to understand the confinement related phenomenon in fusion devices such as impurity transport and plays an important role in impurity control. During the Wendelstein 7-X (W7-X) operation phase 1.2a, a multi-channel (MC) Mach probe mounted on the multi-purpose manipulator has been used to measure radial profiles of edge ion flow velocity. This MC-Mach probe consists of two polar and two radial arrays of directional Langmuir pins (28 pins in total) serving for different aims, of which the polar arrays could obtain a polar distribution of ion saturation current, while the radial arrays can be used to study the dynamic process of a radially propagated event. In this paper, we report the observation of the radially outward propagation of a low frequency mode with a speed of around 200 m/s. The first measurement of the radial ion flow velocity profile using the MC-Mach probe in the boundary plasma of the W7-X with an island divertor will also be presented.
- 1 March 2019
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 90 (3) , 033502
A new multi-channel Mach probe measuring the radial ion flow velocity profile in the boundary plasma of the W7-X stellarator
Ion flow velocity measurement in the edge and scraper-off layer region is beneficial to understand the confinement related phenomenon in fusion devices such as impurity transport and plays an important role in impurity control. During the Wendelstein 7-X (W7-X) operation phase 1.2a, a multi-channel (MC) Mach probe mounted on the multi-purpose manipulator has been used to measure radial profiles of edge ion flow velocity. This MC-Mach probe consists of two polar and two radial arrays of directional Langmuir pins (28 pins in total) serving for different aims, of which the polar arrays could obtain a polar distribution of ion saturation current, while the radial arrays can be used to study the dynamic process of a radially propagated event. In this paper, we report the observation of the radially outward propagation of a low frequency mode with a speed of around 200 m/s. The first measurement of the radial ion flow velocity profile using the MC-Mach probe in the boundary plasma of the W7-X with an island divertor will also be presented.
- 27 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10F111
Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator
The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.
- 27 September 2018
- Published by AIP Publishing in Review of Scientific Instruments
- Vol. 89 (10) , 10F111
Plasma impurities observed by a pulse height analysis diagnostic during the divertor campaign of the Wendelstein 7-X stellarator
The paper reports on the optimization process of the soft X-ray pulse height analyzer installed on the Wendelstein 7-X (W7-X) stellarator. It is a 3-channel system that records X-ray spectra in the range from 0.6 to 19.6 keV. X-ray spectra, with a temporal and spatial resolution of 100 ms and 2.5 cm (depending on selected slit sizes), respectively, are line integrated along a line-of-sight that crosses near to the plasma center. In the second W7-X operation phase with a carbon test divertor unit, light impurities, e.g., carbon and oxygen, were observed as well as mid- to high-Z elements, e.g., sulfur, chlorine, chromium, manganese, iron, and nickel. In addition, X-ray lines from several tracer elements have been observed after the laser blow-off injection of different impurities, e.g., silicon, titanium, and iron, and during discharges with prefill or a gas puff of neon or argon. These measurements were achieved by optimizing light absorber-foil selection, which defines the detected energy range, and remotely controlled pinhole size, which defines photon flux. The identification of X-ray lines was confirmed by other spectroscopic diagnostics, e.g., by the High-Efficiency XUV Overview Spectrometer, HEXOS, and high-resolution X-ray imaging spectrometer, HR-XIS.