Flavia Meccio
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Flavia Meccio has a total of 17 co-authors. Here are the top co-authors by number of shared publications:
- Rosario Maugeri
Neurosurgical Clinic, AOUP “Paolo Giaccone”, Post Graduate Residency Program in Neurologic Surgery, Department of Experimental Biomedicine and Clinical Neurosciences, School of Medicine, University of Palermo, 90133 Palermo, Italy
2 shared publications - Alessandra Provenzano
Neurosurgical Clinic, AOUP “Paolo Giaccone”, Post Graduate Residency Program in Neurologic Surgery, Department of Experimental Biomedicine and Clinical Neurosciences, School of Medicine, University of Palermo, 90127 Palermo, Italy
1 shared publication - Alessio Albanese
Department of Neurosurgery, Fondazione Policlinico Universitario A. Gemelli IRCCS, Università Cattolica del Sacro Cuore, Rome, Italy
1 shared publication - Domenico Gerardo Iacopino
Neurosurgical Clinic, AOUP “Paolo Giaccone”, Post Graduate Residency Program in Neurologic Surgery, Department of Experimental Biomedicine and Clinical Neurosciences, School of Medicine, University of Palermo, 90133 Palermo, Italy
1 shared publication - Domenico Gerardo Iacopino
Neurosurgical Clinic, AOUP “Paolo Giaccone”, Post Graduate Residency Program in Neurologic Surgery, Department of Experimental Biomedicine and Clinical Neurosciences, School of Medicine, University of Palermo, 90127 Palermo, Italy
1 shared publication - Evier Andrea Giovannini
Neurosurgical Clinic, AOUP “Paolo Giaccone”, Post Graduate Residency Program in Neurologic Surgery, Department of Experimental Biomedicine and Clinical Neurosciences, School of Medicine, University of Palermo, 90127 Palermo, Italy
1 shared publication
Latest Publications
- Open Access
- 2 October 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (10) , 1409
Assessing the Training in Neurosurgery with the Implementation of VITOM-3D Exoscope: Learning Curve on Experimental Model in Neurosurgical Practice
(1) Background: Innovation and continuous demand in the field of visual enhancing technologies and video streaming have led to the discovery of new systems capable of improving visualization and illumination of the surgical field. The exoscope was brought into neurosurgical routine, and nearly ten years later, modern 3D systems have been introduced and tested, giving encouraging results. (2) Methods: In order to evaluate the surgeon’s confidence with the exoscope and their increasing ability in terms of time spent and quality of the final achievement since their first encounter with the technique, an experimental trial on 18 neurosurgeons from a single Institution was performed to evaluate the learning curve for the use of the VITOM-3D exoscope in neurosurgical practice on a model of brain and dura mater. (3) Results: A significant improvement in the quality of the performance, number of errors made, and reduction in the time was found after the third iteration of the task, by when almost all the participants felt more comfortable and confident. No significant differences between senior neurosurgeons and resident neurosurgeons were reported. (4) Conclusions: Our results show that three iterations are enough to gain confidence with the exoscope from its first use, regardless of previous experience and training with an operating microscope.
- 2 October 2023
- Published by MDPI AG in Brain Sciences
- Vol. 13 (10) , 1409
Open AccessAssessing the Training in Neurosurgery with the Implementation of VITOM-3D Exoscope: Learning Curve on Experimental Model in Neurosurgical Practice
(1) Background: Innovation and continuous demand in the field of visual enhancing technologies and video streaming have led to the discovery of new systems capable of improving visualization and illumination of the surgical field. The exoscope was brought into neurosurgical routine, and nearly ten years later, modern 3D systems have been introduced and tested, giving encouraging results. (2) Methods: In order to evaluate the surgeon’s confidence with the exoscope and their increasing ability in terms of time spent and quality of the final achievement since their first encounter with the technique, an experimental trial on 18 neurosurgeons from a single Institution was performed to evaluate the learning curve for the use of the VITOM-3D exoscope in neurosurgical practice on a model of brain and dura mater. (3) Results: A significant improvement in the quality of the performance, number of errors made, and reduction in the time was found after the third iteration of the task, by when almost all the participants felt more comfortable and confident. No significant differences between senior neurosurgeons and resident neurosurgeons were reported. (4) Conclusions: Our results show that three iterations are enough to gain confidence with the exoscope from its first use, regardless of previous experience and training with an operating microscope.
- Open Access
- 1 January 2016
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 7 (4) , 77-82
Aulogous fibrin sealant (Vivostat®) in the neurosurgical practice: Part II: Vertebro-spinal procedures
Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to provide rapid hemostasis and/or to seal the dura. Only 2 patients developed postoperative dural fistulas while none exhibited hemorrhages, allergic reactions, systemic complications, or infections. In this preliminary study, the application of autologous fibrin sealant with Vivostat(®) resulted in rapid hemostasis and/or acted as an effective dural sealant. Although this product appears to be safe and effective, further investigations are warranted.
- 1 January 2016
- Published by Scientific Scholar in Surgical Neurology International
- Vol. 7 (4) , 77-82
Open AccessAulogous fibrin sealant (Vivostat®) in the neurosurgical practice: Part II: Vertebro-spinal procedures
Epidural hematomas, cerebrospinal fluid fistula, and spinal infections are challenging postoperative complications following vertebro-spinal procedures. We report our preliminary results using autologous fibrin sealant as both fibrin glue and a hemostatic during these operations. Prospectively, between January 2013 and March 2015, 68 patients received an autologous fibrin sealant prepared with the Vivostat(®) system applied epidurally to provide hemostasis and to seal the dura. The surgical technique, time to bleeding control, and associated complications were recorded. Spinal procedures were performed in 68 patients utilizing autologous fibrin glue/Vivostat(®) to provide rapid hemostasis and/or to seal the dura. Only 2 patients developed postoperative dural fistulas while none exhibited hemorrhages, allergic reactions, systemic complications, or infections. In this preliminary study, the application of autologous fibrin sealant with Vivostat(®) resulted in rapid hemostasis and/or acted as an effective dural sealant. Although this product appears to be safe and effective, further investigations are warranted.