Mark T. Ehrensberger
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Mark T. Ehrensberger has a total of 186 co-authors. Here are the top co-authors by number of shared publications:
Menachem Tobias
Inc., a Wiley Company, 111 River St., Hoboken, NJ 07030-5774 USA
5 shared publicationsAnthony A. Campagnari
Department of Microbiology and Immunology, State University of New York at Buffalo, Buffalo, New York
4 shared publicationsEmily K. Brooks
Department of Biomedical Engineering, State University of New York at Buffalo, United States
4 shared publicationsLinda Wild
Professor of Biomaterials Department of Biomedical and Chemical Engineering L.C. Smith College of Engineering and
4 shared publicationsLisa A. Hansen
Professor of Biomaterials Department of Biomedical and Chemical Engineering L.C. Smith College of Engineering and
3 shared publicationsMenachem E. Tobias
Department of Orthopedics, State University of New York at Buffalo, Buffalo, New York
3 shared publications
Latest Publications
- 3 August 2022
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 52 (10) , 1525-1534
Electrochemical techniques to investigate adsorption and desorption behavior of fibrinogen on a gold surface
- 3 August 2022
- Published by Springer Nature in Journal of Applied Electrochemistry
- Vol. 52 (10) , 1525-1534
Electrochemical techniques to investigate adsorption and desorption behavior of fibrinogen on a gold surface
- 6 May 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 96, 105665
Reverse total shoulder arthroplasty baseplate stability with locking vs. non-locking peripheral screws
- 6 May 2022
- Published by Elsevier in Clinical Biomechanics
- Vol. 96, 105665
Reverse total shoulder arthroplasty baseplate stability with locking vs. non-locking peripheral screws
- Open Access
- 1 January 2021
- Published by Elsevier in Journal of Shoulder and Elbow Arthroplasty
- Vol. 5
Reverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant
- 1 January 2021
- Published by Elsevier in Journal of Shoulder and Elbow Arthroplasty
- Vol. 5
Open AccessReverse Total Shoulder Arthroplasty Baseplate Stability in Superior Bone Loss With Augmented Implant
- Open Access
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Development of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.
- 13 March 2020
- Published by Wiley in MEDICAL DEVICES & SENSORS
- Vol. 3 (5)
Open AccessDevelopment of durable microelectrodes for the detection of hydrogen peroxide and pH
Cathodic electrical stimulation has been investigated as a way to treat implant‐associated infection of orthopaedic devices. One of the proposed mechanisms of these effects is the changes in chemical gradients adjacent to the implant generated by the cathodic reaction products. Of these reaction products, both alkaline pH and hydrogen peroxide have been implicated as antimicrobial agents. However, direct measurement of these chemical effects has yet to be fully characterized for orthopaedic biomaterials. Microelectrodes are powerful tools that can be used to measure localized chemical conditions. Most commercially available sensors are fabricated from pulled glass pipettes, which make them quite fragile. In order to more easily make measurements of the effects of electrical stimulation, more durable sensors are desired. Solid‐state electrodes were fabricated from platinum and iridium micro‐wires to make H2O2 and pH‐sensitive electrodes, respectively. Additionally, a similar method was used to fabricate electrodes that were housed within a stainless steel needle, which could be used to penetrate and measure in solid samples without damaging the sensor. The H2O2 microelectrode was found to have a sensitivity of 34.1 pA/µM and a R2 value of .996. The pH microelectrode was found to have a linear calibration from 2 to 12 with a sensitivity of 76.7 mV/pH and a R2 of .996. The needle‐based electrodes were found to be able to detect changes in both H2O2 and pH when tested in an agar gel model.
- Open Access
- 19 November 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 10 (1) , 17-41
Electrochemical methods to enhance osseointegrated prostheses
Osseointegrated (OI) prosthetic limbs have been shown to provide an advantageous treatment option for amputees. In order for the OI prosthesis to be successful, the titanium implant must rapidly achieve and maintain proper integration with the bone tissue and remain free of infection. Electrochemical methods can be utilized to control and/or monitor the interfacial microenvironment where the titanium implant interacts with the biological system (host bone tissue or bacteria). This review will summarize the current understanding of how electrochemical modalities can influence bone tissue and bacteria with specific emphasis on applications where the metallic prosthesis itself can be utilized directly as a stimulating electrode for enhanced osseointegration and infection control. In addition, a summary of electrochemical impedance sensing techniques that could be used to potentially assess osseointegration and infection status of the metallic prosthesis is presented.
- 19 November 2019
- Published by Springer Nature in Biomedical Engineering Letters
- Vol. 10 (1) , 17-41
Open AccessElectrochemical methods to enhance osseointegrated prostheses
Osseointegrated (OI) prosthetic limbs have been shown to provide an advantageous treatment option for amputees. In order for the OI prosthesis to be successful, the titanium implant must rapidly achieve and maintain proper integration with the bone tissue and remain free of infection. Electrochemical methods can be utilized to control and/or monitor the interfacial microenvironment where the titanium implant interacts with the biological system (host bone tissue or bacteria). This review will summarize the current understanding of how electrochemical modalities can influence bone tissue and bacteria with specific emphasis on applications where the metallic prosthesis itself can be utilized directly as a stimulating electrode for enhanced osseointegration and infection control. In addition, a summary of electrochemical impedance sensing techniques that could be used to potentially assess osseointegration and infection status of the metallic prosthesis is presented.
- Open Access
- 8 December 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (1) , 1-8
Issue Information
- 8 December 2017
- Published by Wiley in Journal of Biomedical Materials Research Part B: Applied Biomaterials
- Vol. 106 (1) , 1-8
Open AccessIssue Information
- 1 October 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (10) , 1748-1755
Reverse total shoulder glenoid baseplate stability with superior glenoid bone loss
- 1 October 2017
- Published by Elsevier in Journal of Shoulder and Elbow Surgery
- Vol. 26 (10) , 1748-1755
Reverse total shoulder glenoid baseplate stability with superior glenoid bone loss
- Open Access
- 1 September 2017
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 8 (3) , 38
Bio-Corrosion of Magnesium Alloys for Orthopaedic Applications
Three Mg alloys, Mg–1.34% Ca–3% Zn (MCZ), Mg–1.34% Ca–3% Zn–0.2% Sr (MCZS), and Mg–2% Sr (MS), were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM) of alloy microstructure was performed to help interpret the results of the electrochemical testing. Results indicate that corrosion resistance of the alloys is as follows: MCZ > MCZS > MS.
- 1 September 2017
- Published by MDPI AG in Journal of Functional Biomaterials
- Vol. 8 (3) , 38
Open AccessBio-Corrosion of Magnesium Alloys for Orthopaedic Applications
Three Mg alloys, Mg–1.34% Ca–3% Zn (MCZ), Mg–1.34% Ca–3% Zn–0.2% Sr (MCZS), and Mg–2% Sr (MS), were examined to understand their bio-corrosion behavior. Electrochemical impedance spectroscopy and polarization scans were performed after 6 days of immersion in cell culture medium, and ion release and changes in media pH were tracked over a 28 day time period. Scanning electron microscopy (SEM) of alloy microstructure was performed to help interpret the results of the electrochemical testing. Results indicate that corrosion resistance of the alloys is as follows: MCZ > MCZS > MS.
- 1 February 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 71, 200-205
Effects of simulated inflammation on the corrosion of 316L stainless steel
- 1 February 2017
- Published by Elsevier in Materials Science and Engineering: C
- Vol. 71, 200-205
Effects of simulated inflammation on the corrosion of 316L stainless steel