Lingzhi Li
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Lingzhi Li has a total of 48 co-authors. Here are the top co-authors by number of shared publications:
- Hui Cai
College of Mechanical and Electrical Engineering, China Jiliang University, Hangzhou, China
3 shared publications Hui Cai
2 shared publicationsXin Zhang
2 shared publicationsZhoujing Wang
2 shared publications- Adrian Keating
Department of Electrical Electronic and Computer Engineering University of Western Australia 35 Stirling Hwy Crawley 6009 Australia
1 shared publication - Bing Yan
Guangzhou University
1 shared publication
Latest Publications
- Open Access
- 23 October 2026
- Published by Elsevier in SSRN Electronic Journal
Mechanical looseness fault diagnosis of HVSR based on multi-point energy,relative change fuzzy entropy
High-voltage shunt reactor (HVSR) serves as essential inductive equipment in ultra-high-voltage (UHV) power grids, providing reactive power compensation and improving power quality. However, HVSR adopts multi-air-gap segmented core structures, which generate more complex electromagnetic forces than transformers. Accordingly, HVSR suffers an elevated risk of mechanical looseness arising from the gapped core and winding components. Undetected loosening will threaten the operational safety of power grids. To the best of the authors’ knowledge, few published methods can accurately identify looseness-originating components together with their loosening severity. To address this issue, this paper proposes a fault diagnosis method based on the vibration signals of HVSR. Focusing on two typical HVSR looseness faults, namely gapped core looseness and winding looseness, an energy relative change (ERC) is first constructed to characterize vibration energy variations. Multi-point fuzzy entropy is subsequently introduced to enhance signal detail representation. Finally, energy relative change and fuzzy entropy for multiple points (EFM) are integrated as the diagnostic feature. Four mainstream classifiers are combined with EFM. Validated on a self-built HVSR fault simulation experimental platform, all models achieve accuracies above 97% under sufficient samples. They retain approximately 90% accuracy under the small-sample scenario with only 1% sample proportion. Moreover, the EFM exhibits strong robustness against disturbances at a signal-to-noise ratio (SNR) of 20 dB. Independent of complex classification architectures, EFM achieves reliable diagnostic performance with mainstream classifiers under limited samples. The proposed method effectively diagnoses HVSR loosened components along with their severity, thereby providing support for targeted fault handling and power-supply reliability.
- 23 October 2026
- Published by Elsevier in SSRN Electronic Journal
Open AccessMechanical looseness fault diagnosis of HVSR based on multi-point energy,relative change fuzzy entropy
High-voltage shunt reactor (HVSR) serves as essential inductive equipment in ultra-high-voltage (UHV) power grids, providing reactive power compensation and improving power quality. However, HVSR adopts multi-air-gap segmented core structures, which generate more complex electromagnetic forces than transformers. Accordingly, HVSR suffers an elevated risk of mechanical looseness arising from the gapped core and winding components. Undetected loosening will threaten the operational safety of power grids. To the best of the authors’ knowledge, few published methods can accurately identify looseness-originating components together with their loosening severity. To address this issue, this paper proposes a fault diagnosis method based on the vibration signals of HVSR. Focusing on two typical HVSR looseness faults, namely gapped core looseness and winding looseness, an energy relative change (ERC) is first constructed to characterize vibration energy variations. Multi-point fuzzy entropy is subsequently introduced to enhance signal detail representation. Finally, energy relative change and fuzzy entropy for multiple points (EFM) are integrated as the diagnostic feature. Four mainstream classifiers are combined with EFM. Validated on a self-built HVSR fault simulation experimental platform, all models achieve accuracies above 97% under sufficient samples. They retain approximately 90% accuracy under the small-sample scenario with only 1% sample proportion. Moreover, the EFM exhibits strong robustness against disturbances at a signal-to-noise ratio (SNR) of 20 dB. Independent of complex classification architectures, EFM achieves reliable diagnostic performance with mainstream classifiers under limited samples. The proposed method effectively diagnoses HVSR loosened components along with their severity, thereby providing support for targeted fault handling and power-supply reliability.
- 24 January 2026
- Published by Elsevier in Building and Environment
- Vol. 292
A novel distributed cooperative control air balancing method with source-terminal synchronous regulation for HVAC system
- 24 January 2026
- Published by Elsevier in Building and Environment
- Vol. 292
A novel distributed cooperative control air balancing method with source-terminal synchronous regulation for HVAC system
- 17 March 2025
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 34 (4) , 776-790
A heating control mode for the hybrid passive thermosiphon beam
As a novel type of air conditioning terminal, the hybrid passive thermosiphon beam (HPTB) can form the thermosiphon effect under refrigeration operation, which benefits both body comfort and energy saving. However, in temperate regions, winter heating is also crucial. There is a lack of research on the heating mode with its control for the HPTB. Therefore, this study investigated the heating mode of HPTB and introduced a heating control model. Based on the temperature control principle of HPTB, the heat transfer function of the controlled room was established. A fuzzy PI control method was developed with the control parameters estimated. The experimental platform with a multi-area room temperature control system was set up for the verification. The proposed control method was proven that it can reasonably distribute the flow of cold and hot medium of HPTB in each room. In heating mode, this control method can help the HPTB to develop stable and unified indoor temperature environment. This study provides a basis for the seasonal temperature control and application by HPTB in temperate regions, which further promotes the popularization of the thermosiphon beam air conditioning terminals.
- 17 March 2025
- Published by SAGE Publications in Indoor and Built Environment
- Vol. 34 (4) , 776-790
A heating control mode for the hybrid passive thermosiphon beam
As a novel type of air conditioning terminal, the hybrid passive thermosiphon beam (HPTB) can form the thermosiphon effect under refrigeration operation, which benefits both body comfort and energy saving. However, in temperate regions, winter heating is also crucial. There is a lack of research on the heating mode with its control for the HPTB. Therefore, this study investigated the heating mode of HPTB and introduced a heating control model. Based on the temperature control principle of HPTB, the heat transfer function of the controlled room was established. A fuzzy PI control method was developed with the control parameters estimated. The experimental platform with a multi-area room temperature control system was set up for the verification. The proposed control method was proven that it can reasonably distribute the flow of cold and hot medium of HPTB in each room. In heating mode, this control method can help the HPTB to develop stable and unified indoor temperature environment. This study provides a basis for the seasonal temperature control and application by HPTB in temperate regions, which further promotes the popularization of the thermosiphon beam air conditioning terminals.
- 11 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 41, 558-562
SOC Prediction of Pure Electric Vehicle Battery Based on Cnn-lstm
Pure electric vehicles will gradually replace traditional cars because of their green, environmental protection, safety and reliability. During the operation of pure electric vehicle, SOC is an important parameter in the driving process of electric vehicle.Taking the battery data of pure electric vehicle as the research object, this paper studies the SOC prediction of pure electric vehicle battery. Firstly, this paper briefly describes the data involved in this paper, then processes the missing values, abnormal values and invalid data in the data set, and extracts the charging data of pure electric vehicles. Then, through the analysis of data features and the extraction of features through Pearson correlation coefficient, cnn-lstm model is established to predict SOC. Finally, with CNN RNN and LSTM models are compared and analyzed. The analysis results show that cnn-lstm has a good effect on SOC prediction of pure electric vehicles. Compared with other algorithms, cnn-lstm has high accuracy and small error.
- 11 October 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 41, 558-562
SOC Prediction of Pure Electric Vehicle Battery Based on Cnn-lstm
Pure electric vehicles will gradually replace traditional cars because of their green, environmental protection, safety and reliability. During the operation of pure electric vehicle, SOC is an important parameter in the driving process of electric vehicle.Taking the battery data of pure electric vehicle as the research object, this paper studies the SOC prediction of pure electric vehicle battery. Firstly, this paper briefly describes the data involved in this paper, then processes the missing values, abnormal values and invalid data in the data set, and extracts the charging data of pure electric vehicles. Then, through the analysis of data features and the extraction of features through Pearson correlation coefficient, cnn-lstm model is established to predict SOC. Finally, with CNN RNN and LSTM models are compared and analyzed. The analysis results show that cnn-lstm has a good effect on SOC prediction of pure electric vehicles. Compared with other algorithms, cnn-lstm has high accuracy and small error.
- 1 February 2022
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 424 (Pt C) , 127521
Biosafety-inspired structural optimization of triazolium ionic liquids based on structure-toxicity relationships
- 1 February 2022
- Published by Elsevier in Journal of Hazardous Materials
- Vol. 424 (Pt C) , 127521
Biosafety-inspired structural optimization of triazolium ionic liquids based on structure-toxicity relationships
- Open Access
- 1 January 2021
- Published by ECCOMAS
- p. 4582-4592
A COMPARATIVE STUDY ON SEISMIC RESPONSE OF A SUPER HIGH-RISE BUILDING USING CONVENTIONAL AND MODAL PUSHOVER ANALYSIS
A COMPARATIVE STUDY ON SEISMIC RESPONSE OF A SUPER HIGH-RISE BUILDING USING CONVENTIONAL AND MODAL PUSHOVER ANALYSIS - 8th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering - 28-30 June 2021, Streamed from Athens, Greece
- 1 January 2021
- Published by ECCOMAS
- p. 4582-4592
Open AccessA COMPARATIVE STUDY ON SEISMIC RESPONSE OF A SUPER HIGH-RISE BUILDING USING CONVENTIONAL AND MODAL PUSHOVER ANALYSIS
A COMPARATIVE STUDY ON SEISMIC RESPONSE OF A SUPER HIGH-RISE BUILDING USING CONVENTIONAL AND MODAL PUSHOVER ANALYSIS - 8th International Conference on Computational Methods in Structural Dynamics and Earthquake Engineering - 28-30 June 2021, Streamed from Athens, Greece
- Open Access
- 6 March 2019
- Published by MDPI AG in Electronics
- Vol. 8 (3)
Distributed Magnetic Flux Density on the Cross-Section of a Transformer Core
In this paper, the magnetic flux density distribution on the cross-sections of a transformer core is studied. The core for this study consists of two identical U-shaped cores joint at their open surfaces with known air gaps. The magnetic flux density at one of their joint boundary surfaces was measured for different air gaps. A finite element model (FEM) was built to simulate the magnetic flux density and compared with experiment data. Using the validated FEM, the distributed magnetic flux density on the cross-section of the core structure can be obtained when the air gap approaches zero. An engineering model of the density based on the Ampere’s circuit law was also developed and used to explain the relationship between air gap and mean magnetic flux density on the cross-section. The magnetic flux density on the cross-section was found to have a convex-shaped distribution and could be described by an empirical formula. Using this approach, the magnetic flux density distribution in cores with different interlayer insulation was obtained and discussed. This method could also examine the leakage of magnetic flux density in the air gap region when the distance is non-zero, and the relationship between the leakage field and the field in the core structure. The proposed method and model can provide a more detailed understanding for the magnetic field of transformer cores and potential application in designing quiet transformers and condition monitoring.
- 6 March 2019
- Published by MDPI AG in Electronics
- Vol. 8 (3)
Open AccessDistributed Magnetic Flux Density on the Cross-Section of a Transformer Core
In this paper, the magnetic flux density distribution on the cross-sections of a transformer core is studied. The core for this study consists of two identical U-shaped cores joint at their open surfaces with known air gaps. The magnetic flux density at one of their joint boundary surfaces was measured for different air gaps. A finite element model (FEM) was built to simulate the magnetic flux density and compared with experiment data. Using the validated FEM, the distributed magnetic flux density on the cross-section of the core structure can be obtained when the air gap approaches zero. An engineering model of the density based on the Ampere’s circuit law was also developed and used to explain the relationship between air gap and mean magnetic flux density on the cross-section. The magnetic flux density on the cross-section was found to have a convex-shaped distribution and could be described by an empirical formula. Using this approach, the magnetic flux density distribution in cores with different interlayer insulation was obtained and discussed. This method could also examine the leakage of magnetic flux density in the air gap region when the distance is non-zero, and the relationship between the leakage field and the field in the core structure. The proposed method and model can provide a more detailed understanding for the magnetic field of transformer cores and potential application in designing quiet transformers and condition monitoring.