Xiaowei Huang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Xiaowei Huang has a total of 8 co-authors. Here are the top co-authors by number of shared publications:
- Baoqing Yu
Department of Orthopedics, Shanghai Pudong Hospital, Fudan University Pudong Medical Center, No. 2800 Gongwei Road, Huinan Town, Pudong New Area, Shanghai City, China.
1 shared publication - Bingli Liu
Department of Joint Surgery, Seventh People’s Hospital of Shanghai University of Traditional Chinese Medicine, Shanghai, China
1 shared publication Fancheng Chen
Department of Orthopedics, The Seventh People's Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China
1 shared publication- Fancheng Chen
Shanghai Medical College, Fudan University, Shanghai, China.
1 shared publication Wei Geng
Department of Orthopedics, The First Affiliated Hospital of Soochow University, Suzhou, China
1 shared publicationXiaowen Lai
Department of General Surgery, The Seventh People's Hospital Affiliated to Shanghai University of Traditional Chinese Medicine, Shanghai, China
1 shared publication
Latest Publications
- 27 March 2026
- Published by Elsevier in Phytomedicine
- Vol. 155, 158116
Isoeugenol suppression of osteoporosis by modulating macrophage M1 Polarization via p38 MAPK and arachidonic acid metabolism pathways
- 27 March 2026
- Published by Elsevier in Phytomedicine
- Vol. 155, 158116
Isoeugenol suppression of osteoporosis by modulating macrophage M1 Polarization via p38 MAPK and arachidonic acid metabolism pathways
- Open Access
- 25 November 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 1-9
Stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60 % to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.
- 25 November 2015
- Published by Springer Nature in Journal of Orthopaedic Surgery and Research
- Vol. 10 (1) , 1-9
Open AccessStress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture: a comparative finite element study
The purpose of this study is to compare the stress and stability of plate-screw fixation and screw fixation in the treatment of Schatzker type IV medial tibial plateau fracture. A three-dimensional (3D) finite element model of the medial tibial plateau fracture (Schatzker type IV fracture) was created. An axial force of 2500 N with a distribution of 60 % to the medial compartment was applied to simulate the axial compressive load on an adult knee during single-limb stance. The equivalent von Mises stress, displacement of the model relative to the distal tibia, and displacement of the implants were used as the output measures. The mean stress value of the plate-screw fixation system was 18.78 MPa, which was significantly (P < 0.001) smaller than that of the screw fixation system. The maximal value of displacement (sum) in the plate-screw fixation system was 2.46 mm, which was lower than that in the screw fixation system (3.91 mm). The peak stress value of the triangular fragment in the plate-screw fixation system model was 42.04 MPa, which was higher than that in the screw fixation model (24.18 MPa). But the mean stress of the triangular fractured fragment in the screw fixation model was significantly higher in terms of equivalent von Mises stress (EVMS), x-axis, and z-axis (P < 0.001). This study demonstrated that the load transmission mechanism between plate-screw fixation system and screw fixation system was different and the stability provided by the plate-screw fixation system was superior to the screw fixation system.