Fei Xie
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Fei Xie has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Shu Wang
Breast Center, Peking University People’s Hospital, Beijing 100044, China
2 shared publications - Dongjie Zhang
Department of Breast Disease, Peking University People’s Hospital, Beijing, China
1 shared publication - Fuzhong Tong
Department of Breast Disease, Peking University People’s Hospital, Beijing, China
1 shared publication - Hongjun Liu
Department of Breast Disease, Peking University People’s Hospital, Beijing, China
1 shared publication - Lei Yu
Department of Ultrasound Diagnosis, Peking University People’s Hospital, Beijing, China
1 shared publication - Li Yang
Department of Ultrasound Diagnosis, Peking University People’s Hospital, Beijing, China
1 shared publication
Latest Publications
- 1 May 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 516, 55-63
Four novel BRCA variants found in Chinese hereditary breast cancer patients by next-generation sequencing
- 1 May 2021
- Published by Elsevier in Clinica Chimica Acta
- Vol. 516, 55-63
Four novel BRCA variants found in Chinese hereditary breast cancer patients by next-generation sequencing
- Open Access
- 19 November 2015
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 13 (1) , 1-8
Intradermal microbubbles and contrast-enhanced ultrasound (CEUS) is a feasible approach for sentinel lymph node identification in early-stage breast cancer
Microbubbles and contrast-enhanced ultrasound (CEUS) is a new technique for locating sentinel lymph node (SLN). The aim of this study is to explore the feasibility of SLNs tracing by CEUS using microbubbles in breast cancer patients and the value of enhancing patterns in diagnosing lymph nodes metastases. A clinical trial was registered (trial registration: ChiCTR-DDT-13003778). One hundred and one consecutive consenting patients with breast cancer undergoing SLN biopsy were enrolled. Before the surgery, microbubble was injected periareolarly. Lymphatic drainage pathway was detected by CEUS, and guidewire was deployed to locate the SLN before the operation. Blue dye was also used to help in tracing sentinel lymph node during the operation. The identification rate and the accuracy rate were recorded. Enhancing patterns of lymph nodes were recorded and compared with the pathological diagnosis. Of the 101 cases, SLNs in 99 cases were successfully identified by at least one tracer, including 98 cases identified by CEUS and 97 cases by blue dye. There was no significant difference between the two methods (P = 0.705). Guidewires were deployed successfully in all 98 cases, and the localized SLNs were all isolated successfully in the following operations. The status of SLNs isolated by CEUS was completely identical to that of the whole axillary lymph node while 7.1 % cases were misdiagnosed as negative by blue dye method. The sensitivity of predicting SLNs metastases by CEUS enhancing pattern was 81.8 %, the specificity was 86.2 %, and the positive and negative predictive values were 75.0 and 90.3 %, respectively. Microbubbles and CEUS are feasible approaches for SLN identification. The enhancing patterns on CEUS may be helpful to recognize the metastasizing SLNs. This novel method may be a promising technique for the clinical application.
- 19 November 2015
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 13 (1) , 1-8
Open AccessIntradermal microbubbles and contrast-enhanced ultrasound (CEUS) is a feasible approach for sentinel lymph node identification in early-stage breast cancer
Microbubbles and contrast-enhanced ultrasound (CEUS) is a new technique for locating sentinel lymph node (SLN). The aim of this study is to explore the feasibility of SLNs tracing by CEUS using microbubbles in breast cancer patients and the value of enhancing patterns in diagnosing lymph nodes metastases. A clinical trial was registered (trial registration: ChiCTR-DDT-13003778). One hundred and one consecutive consenting patients with breast cancer undergoing SLN biopsy were enrolled. Before the surgery, microbubble was injected periareolarly. Lymphatic drainage pathway was detected by CEUS, and guidewire was deployed to locate the SLN before the operation. Blue dye was also used to help in tracing sentinel lymph node during the operation. The identification rate and the accuracy rate were recorded. Enhancing patterns of lymph nodes were recorded and compared with the pathological diagnosis. Of the 101 cases, SLNs in 99 cases were successfully identified by at least one tracer, including 98 cases identified by CEUS and 97 cases by blue dye. There was no significant difference between the two methods (P = 0.705). Guidewires were deployed successfully in all 98 cases, and the localized SLNs were all isolated successfully in the following operations. The status of SLNs isolated by CEUS was completely identical to that of the whole axillary lymph node while 7.1 % cases were misdiagnosed as negative by blue dye method. The sensitivity of predicting SLNs metastases by CEUS enhancing pattern was 81.8 %, the specificity was 86.2 %, and the positive and negative predictive values were 75.0 and 90.3 %, respectively. Microbubbles and CEUS are feasible approaches for SLN identification. The enhancing patterns on CEUS may be helpful to recognize the metastasizing SLNs. This novel method may be a promising technique for the clinical application.