WGWendong Gu

Wendong Gu

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Wendong Gu has a total of 22 co-authors. Here are the top co-authors by number of shared publications:

  • Dan Xi

    Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, Changzhou 213003, P.R. China

    1 shared publication
  • Dingshu Tian

    Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China

    1 shared publication
  • Guangyao Sun

    SuperSafety Science and Technology, Co., Ltd., Hefei, China

    1 shared publication
  • Guoping Xu

    Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, Changzhou 213003, P.R. China

    1 shared publication
  • Honglei Pei

    Department of Radiation Oncology, The Third Affiliated Hospital of Soochow University, The First Peoples' Hospital of Changzhou, Changzhou, 213003, China.

    1 shared publication
  • Jieqiong Jiang

    Institute of Nuclear Energy Safety Technology, Hefei Institutes of Physical Science, Chinese Academy of Sciences, Hefei, China

    1 shared publication

Latest Publications

  • Open Access

    Dose Characteristics of a Deep Learning Model for EPID-based In vivo Dosimetry

    by Qilin Li, Dingshu Tian, Guangyao Sun, Wendong Gu, Jieqiong Jiang

    Background: Images from onboard electronic portal imaging devices (EPID) contain dose information that can be converted into dose maps. A cycle-consistent generative adversarial network (CycleGAN)-based model was developed for two-dimensional (2D) EPID dosimetry, and the dose characteristics of the model were evaluated carefully. Materials and Methods: All the measurements were done on a linac equipped with an EPID detector. This experiment involved: (1) assessing the dose characteristics of the EPID and (2) using a commercial treatment planning system to calculate dose distributions in a slab phantom, which were taken as the ground truth in CycleGAN-based models for converting the EPID images to 2D dose maps. There were about 780 beams delivered to EPID through a slab phantom. There were two normalization methods (NM): I: based on the highest possible value: 65,535 (16 bit); II: by its own maximum pixel value. To evaluate the model, gamma analyses between the ground truth and the output were performed with in-house software; and the dose linearity of the model was checked carefully. A comparative analysis was conducted to evaluate the outcomes stemming from two distinct NMs applied to the input data. Results: The dose characteristics of the EPID demonstrated exceptional precision. Notably, the beam output factors exhibited considerable variations with the increasing thickness of the phantom. Specifically, when the phantom thickness surpassed 12 cm, the trend lines exhibited a pronounced linearity. Deep learning models efficiently transformed EPID images into planar dose maps, albeit exhibiting dose nonlinearity that could be mitigated by choose the suitable normalization medthods. The mean pass rates of gamma analyses (3 mm, 3%) of data normalized by the way I or II were 85.5%, 97.9%, respectively. Conclusion: EPID is an excellent flat-panel detector that captures images rich in dose information, which can be effectively transformed into precise planar dose maps using CycleGAN-based models. The trained model could be used in the quality assurance of treatment plans.

  • Open Access

    Systemic immune-inflammation index predicts the clinical outcome in patients with nasopharyngeal carcinoma: a propensity score-matched analysis

    by Wenjie Jiang, Yuan Chen, Jin Huang, Dan Xi, Jun Chen, Yingjie Shao, Guoping Xu, Wenming Ying, Jun Wei, Junjun Chen, et al.

    Systemic immune-inflammation index predicts the clinical outcome in patients with nasopharyngeal carcinoma: a propensity score-matched analysis Systemic immune-inflammation index predicts the clinical outcome in patients with nasopharyngeal carcinoma: a propensity score-matched analysis


  • Open Access

    Collimator rotation in volumetric modulated arc therapy for craniospinal irradiation and the dose distribution in the beam junction region

    by Qilin Li, Wendong Gu, Jinming Mu, Wenming Yin, Min Gao, Juncong Mo, Honglei Pei

    The purpose of this study was to investigate the role of beam collimator rotation in Volumetric Modulated Arc Therapy (VMAT) for craniospinal irradiation (CSI), and the impact on dose distribution in the beam junctions. Six adult patients were selected for the study. Six VMAT plans with different collimator angles were generated for each patient. The patients were treated in supine position with two beam isocenters. The plans were evaluated by analysis of Dose-Volume Histogram (DVHs) data for planning target volume (PTV) and organs at risk (OAR), and conformity index (CI) and homogeneity index (HI) for the target. Dose distributions in the beam junctions were examined carefully and experimentally validated in phantom, with measurement using an ion chamber array and film. The mean values of HI and CI for the plans with different beam collimator angles were not significantly different. The numbers of segments, monitor units (MUs) and the delivery time of the plans with 45° beam collimator were obviously higher than those in plans with other beam collimator angles. When collimator angle for both sets of beams were set at 0°, there was a 1 mm low dose gap measured in the junction region. By setting the collimator angle to 45°, only two isocenters were needed for the treatment of a target with the length up to 90 cm. The HI and CI of the plans were almost the same, regardless if the collimator angles were at 0°. The collimator angles for at least one set of beams should be off 0° in order to avoid a dose gap in the beam junction region.