Lei Yang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Lei Yang has a total of 32 co-authors. Here are the top co-authors by number of shared publications:
- Tongning Wu
China Academy of Information and Communications Technology, Beijing, China
6 shared publications - Congsheng Li
China Academy of Information and Communications Technology, Beijing, China
4 shared publications - Chen Zhang
China Academy of Information and Communications Technology, No.52, Huayuan bei Road, Beijing 100191, China
2 shared publications Qingmeng Liu
China Academy of Information and Communications Technology
2 shared publications- Bin Lv
China Academy of Information and Communications Technology, Beijing 100191, China
1 shared publication Chao Xu
China Academy of Information and Communications Technology, Beijing, 100191, China
1 shared publication
Latest Publications
- Open Access
- 20 March 2026
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 17, 1758013
Resting-state fMRI dynamic functional network in young children with Tourette syndrome
Introduction: Tourette syndrome (TS) is a neurodevelopmental disorder characterized by involuntary motor and phonic tics, with diagnosis often delayed due to the 1-year symptom duration criterion. This study aimed to explore early neuroimaging biomarkers of TS in young children, by investigating spatiotemporal alterations in dynamic brain network connectivity in 4-6-year-old children with TS. Methods: This retrospective case-control study collected resting-state functional magnetic resonance imaging (fMRI) data from 24 children aged 4-6 years, including 12 drug-naive TS patients and 12 matched healthy controls (N group). Group Independent Component Analysis (GICA) and Independent Vector Analysis (IVA) were used to assess group differences in temporal and spatial dynamic functional network connectivity (FNC), respectively. Correlations between these connectivity alterations and Yale Global Tic Severity Scale (YGTSS) scores as well as disease duration were analyzed. Results: Statistically significant between-group differences were found in temporal dynamic FNC ( p < 0.05), with marginal differences observed in spatial dynamic connectivity ( p < 0.1), primarily involving the ventral default mode network (VDMN), primary visual network (PVN), and precuneus network (PCN). The N group showed a wider range and higher strength of FNC values, while the TS group exhibited abnormally enhanced connectivity in the insula region, which was positively correlated with disease duration. Discussion: This study revealed abnormal temporal and spatial dynamic brain network connectivity in young children at the early stage of TS, particularly in insula-related circuits. These findings provide novel insights into the early neuropathological mechanisms of TS and support the potential of dynamic FNC metrics as early imaging biomarkers for TS in young children.
- 20 March 2026
- Published by Frontiers Media SA in Frontiers in Neurology
- Vol. 17, 1758013
Open AccessResting-state fMRI dynamic functional network in young children with Tourette syndrome
Introduction: Tourette syndrome (TS) is a neurodevelopmental disorder characterized by involuntary motor and phonic tics, with diagnosis often delayed due to the 1-year symptom duration criterion. This study aimed to explore early neuroimaging biomarkers of TS in young children, by investigating spatiotemporal alterations in dynamic brain network connectivity in 4-6-year-old children with TS. Methods: This retrospective case-control study collected resting-state functional magnetic resonance imaging (fMRI) data from 24 children aged 4-6 years, including 12 drug-naive TS patients and 12 matched healthy controls (N group). Group Independent Component Analysis (GICA) and Independent Vector Analysis (IVA) were used to assess group differences in temporal and spatial dynamic functional network connectivity (FNC), respectively. Correlations between these connectivity alterations and Yale Global Tic Severity Scale (YGTSS) scores as well as disease duration were analyzed. Results: Statistically significant between-group differences were found in temporal dynamic FNC ( p < 0.05), with marginal differences observed in spatial dynamic connectivity ( p < 0.1), primarily involving the ventral default mode network (VDMN), primary visual network (PVN), and precuneus network (PCN). The N group showed a wider range and higher strength of FNC values, while the TS group exhibited abnormally enhanced connectivity in the insula region, which was positively correlated with disease duration. Discussion: This study revealed abnormal temporal and spatial dynamic brain network connectivity in young children at the early stage of TS, particularly in insula-related circuits. These findings provide novel insights into the early neuropathological mechanisms of TS and support the potential of dynamic FNC metrics as early imaging biomarkers for TS in young children.
- Open Access
A Deep Learning Framework for Evaluating the Over-the-Air Performance of the Antenna in Mobile Terminals
This study introduces RTEEMF (Real-Time Evaluation Electromagnetic Field)-PhoneAnts, a novel Deep Learning (DL) framework for the efficient evaluation of mobile phone antenna performance, addressing the time-consuming nature of traditional full-wave numerical simulations. The DL model, built on convolutional neural networks, uses the Near-field Electromagnetic Field (NEMF) distribution of a mobile phone antenna in free space to predict the Effective Isotropic Radiated Power (EIRP), Total Radiated Power (TRP), and Specific Absorption Rate (SAR) across various configurations. By converting antenna features and internal mobile phone components into near-field EMF distributions within a Huygens’ box, the model simplifies its input. A dataset of 7000 mobile phone models was used for training and evaluation. The model’s accuracy is validated using the Wilcoxon Signed Rank Test (WSR) for SAR and TRP, and the Feature Selection Validation Method (FSV) for EIRP. The proposed model achieves remarkable computational efficiency, approximately 2000-fold faster than full-wave simulations, and demonstrates generalization capabilities for different antenna types, various frequencies, and antenna positions. This makes it a valuable tool for practical research and development (R&D), offering a promising alternative to traditional electromagnetic field simulations. The study is publicly available on GitHub for further development and customization. Engineers can customize the model using their own datasets.
Open AccessA Deep Learning Framework for Evaluating the Over-the-Air Performance of the Antenna in Mobile Terminals
This study introduces RTEEMF (Real-Time Evaluation Electromagnetic Field)-PhoneAnts, a novel Deep Learning (DL) framework for the efficient evaluation of mobile phone antenna performance, addressing the time-consuming nature of traditional full-wave numerical simulations. The DL model, built on convolutional neural networks, uses the Near-field Electromagnetic Field (NEMF) distribution of a mobile phone antenna in free space to predict the Effective Isotropic Radiated Power (EIRP), Total Radiated Power (TRP), and Specific Absorption Rate (SAR) across various configurations. By converting antenna features and internal mobile phone components into near-field EMF distributions within a Huygens’ box, the model simplifies its input. A dataset of 7000 mobile phone models was used for training and evaluation. The model’s accuracy is validated using the Wilcoxon Signed Rank Test (WSR) for SAR and TRP, and the Feature Selection Validation Method (FSV) for EIRP. The proposed model achieves remarkable computational efficiency, approximately 2000-fold faster than full-wave simulations, and demonstrates generalization capabilities for different antenna types, various frequencies, and antenna positions. This makes it a valuable tool for practical research and development (R&D), offering a promising alternative to traditional electromagnetic field simulations. The study is publicly available on GitHub for further development and customization. Engineers can customize the model using their own datasets.
- Open Access
- 1 January 2023
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 20 (7) , 12454-12471
Study of MI-BCI classification method based on the Riemannian transform of personalized EEG spatiotemporal features
Motor imagery (MI) is a traditional paradigm of brain-computer interface (BCI) and can assist users in creating direct connections between their brains and external equipment. The common spatial patterns algorithm is the most popular spatial filtering technique for collecting EEG signal features in MI-based BCI systems. Due to the defect that it only considers the spatial information of EEG signals and is susceptible to noise interference and other issues, its performance is diminished. In this study, we developed a Riemannian transform feature extraction method based on filter bank fusion with a combination of multiple time windows. First, we proposed the multi-time window data segmentation and recombination method by combining it with a filter group to create new data samples. This approach could capture individual differences due to the variation in time-frequency patterns across different participants, thereby improving the model's generalization performance. Second, Riemannian geometry was used for feature extraction from non-Euclidean structured EEG data. Then, considering the non-Gaussian distribution of EEG signals, the neighborhood component analysis (NCA) algorithm was chosen for feature selection. Finally, to meet real-time requirements and a low complexity, we employed a Support Vector Machine (SVM) as the classification algorithm. The proposed model achieved improved accuracy and robustness. In this study, we proposed an algorithm with superior performance on the BCI Competition IV dataset 2a, achieving an accuracy of 89%, a kappa value of 0.73 and an AUC of 0.9, demonstrating advanced capabilities. Furthermore, we analyzed data collected in our laboratory, and the proposed method achieved an accuracy of 77.4%, surpassing other comparative models. This method not only significantly improved the classification accuracy of motor imagery EEG signals but also bore significant implications for applications in the fields of brain-computer interfaces and neural engineering.
- 1 January 2023
- Published by American Institute of Mathematical Sciences (AIMS) in Mathematical Biosciences and Engineering
- Vol. 20 (7) , 12454-12471
Open AccessStudy of MI-BCI classification method based on the Riemannian transform of personalized EEG spatiotemporal features
Motor imagery (MI) is a traditional paradigm of brain-computer interface (BCI) and can assist users in creating direct connections between their brains and external equipment. The common spatial patterns algorithm is the most popular spatial filtering technique for collecting EEG signal features in MI-based BCI systems. Due to the defect that it only considers the spatial information of EEG signals and is susceptible to noise interference and other issues, its performance is diminished. In this study, we developed a Riemannian transform feature extraction method based on filter bank fusion with a combination of multiple time windows. First, we proposed the multi-time window data segmentation and recombination method by combining it with a filter group to create new data samples. This approach could capture individual differences due to the variation in time-frequency patterns across different participants, thereby improving the model's generalization performance. Second, Riemannian geometry was used for feature extraction from non-Euclidean structured EEG data. Then, considering the non-Gaussian distribution of EEG signals, the neighborhood component analysis (NCA) algorithm was chosen for feature selection. Finally, to meet real-time requirements and a low complexity, we employed a Support Vector Machine (SVM) as the classification algorithm. The proposed model achieved improved accuracy and robustness. In this study, we proposed an algorithm with superior performance on the BCI Competition IV dataset 2a, achieving an accuracy of 89%, a kappa value of 0.73 and an AUC of 0.9, demonstrating advanced capabilities. Furthermore, we analyzed data collected in our laboratory, and the proposed method achieved an accuracy of 77.4%, surpassing other comparative models. This method not only significantly improved the classification accuracy of motor imagery EEG signals but also bore significant implications for applications in the fields of brain-computer interfaces and neural engineering.
- Open Access
- 13 January 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 9, 734370
No Alteration Between Intrinsic Connectivity Networks by a Pilot Study on Localized Exposure to the Fourth-Generation Wireless Communication Signals
Neurophysiological effect of human exposure to radiofrequency signals has attracted considerable attention, which was claimed to have an association with a series of clinical symptoms. A few investigations have been conducted on alteration of brain functions, yet no known research focused on intrinsic connectivity networks, an attribute that may relate to some behavioral functions. To investigate the exposure effect on functional connectivity between intrinsic connectivity networks, we conducted experiments with seventeen participants experiencing localized head exposure to real and sham time-division long-term evolution signal for 30 min. The resting-state functional magnetic resonance imaging data were collected before and after exposure, respectively. Group-level independent component analysis was used to decompose networks of interest. Three states were clustered, which can reflect different cognitive conditions. Dynamic connectivity as well as conventional connectivity between networks per state were computed and followed by paired sample t-tests. Results showed that there was no statistical difference in static or dynamic functional network connectivity in both real and sham exposure conditions, and pointed out that the impact of short-term electromagnetic exposure was undetected at the ICNs level. The specific brain parcellations and metrics used in the study may lead to different results on brain modulation.
- 13 January 2022
- Published by Frontiers Media SA in Frontiers in Public Health
- Vol. 9, 734370
Open AccessNo Alteration Between Intrinsic Connectivity Networks by a Pilot Study on Localized Exposure to the Fourth-Generation Wireless Communication Signals
Neurophysiological effect of human exposure to radiofrequency signals has attracted considerable attention, which was claimed to have an association with a series of clinical symptoms. A few investigations have been conducted on alteration of brain functions, yet no known research focused on intrinsic connectivity networks, an attribute that may relate to some behavioral functions. To investigate the exposure effect on functional connectivity between intrinsic connectivity networks, we conducted experiments with seventeen participants experiencing localized head exposure to real and sham time-division long-term evolution signal for 30 min. The resting-state functional magnetic resonance imaging data were collected before and after exposure, respectively. Group-level independent component analysis was used to decompose networks of interest. Three states were clustered, which can reflect different cognitive conditions. Dynamic connectivity as well as conventional connectivity between networks per state were computed and followed by paired sample t-tests. Results showed that there was no statistical difference in static or dynamic functional network connectivity in both real and sham exposure conditions, and pointed out that the impact of short-term electromagnetic exposure was undetected at the ICNs level. The specific brain parcellations and metrics used in the study may lead to different results on brain modulation.
- Open Access
- 10 January 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (2) , 741
Modulation of Sleep Architecture by Whole-Body Static Magnetic Exposure: A Study Based on EEG-Based Automatic Sleep Staging
A steady increase in sleep problems has been observed along with the development of society. Overnight exposure to a static magnetic field has been found to improve sleep quality; however, such studies were mainly based on subjective evaluation. Thus, the presented data cannot be used to infer sleep architecture in detail. In this study, the subjects slept on a magneto-static mattress for four nights, and self-reported scales and electroencephalogram (EEG) were used to determine the effect of static magnetic field exposure (SMFE) on sleep. Machine learning operators, i.e., decision tree and supporting vector machine, were trained and optimized with the open access sleep EEG dataset to automatically discriminate the individual sleep stages, determined experimentally. SMEF was found to decrease light sleep duration (N2%) by 3.51%, and sleep onset latency (SOL) by 15.83%, while it increased deep sleep duration (N3%) by 8.43%, compared with the sham SMFE group. Further, the overall sleep efficiency (SE) was also enhanced by SMFE. It is the first study, to the best of our knowledge, where the change in sleep architecture was explored by SMFE. Our findings will be useful in developing a non-invasive sleep-facilitating instrument.
- 10 January 2022
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 19 (2) , 741
Open AccessModulation of Sleep Architecture by Whole-Body Static Magnetic Exposure: A Study Based on EEG-Based Automatic Sleep Staging
A steady increase in sleep problems has been observed along with the development of society. Overnight exposure to a static magnetic field has been found to improve sleep quality; however, such studies were mainly based on subjective evaluation. Thus, the presented data cannot be used to infer sleep architecture in detail. In this study, the subjects slept on a magneto-static mattress for four nights, and self-reported scales and electroencephalogram (EEG) were used to determine the effect of static magnetic field exposure (SMFE) on sleep. Machine learning operators, i.e., decision tree and supporting vector machine, were trained and optimized with the open access sleep EEG dataset to automatically discriminate the individual sleep stages, determined experimentally. SMEF was found to decrease light sleep duration (N2%) by 3.51%, and sleep onset latency (SOL) by 15.83%, while it increased deep sleep duration (N3%) by 8.43%, compared with the sham SMFE group. Further, the overall sleep efficiency (SE) was also enhanced by SMFE. It is the first study, to the best of our knowledge, where the change in sleep architecture was explored by SMFE. Our findings will be useful in developing a non-invasive sleep-facilitating instrument.
- 25 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1699-1708
Predicting Over-the-Air Performance Using a Hand Phantom With Large Dielectric Flexibility
This article developed a hand phantom with a large dielectric deviation from the target values, which can be used to estimate over-the-air (OTA) performance just like the Cellular Telecommunications and Internet Association hand phantom. In this article, the dielectric properties were adjusted by varying the graphite composition in the carbon-loaded silicone. Numerical simulations were used to determine the appropriate material recipe with the aid of the numerical models of four mobile devices operating from 870 to 2700 MHz, using both top and bottom antenna configurations. The results estimated that the material with a difference of 44.65% ± 20.15% (mean ± standard deviation, the maximum value is 77.97%) and 6.79% ± 3.35% (mean ± standard deviation, the maximum value is 9.43%) from the target conductivity and relative permittivity, respectively, provided the maximum deviation of 1.82 dB in the case of total radiated power (TRP) and 1.98 dB for total isotropic sensitivity (TIS). Accordingly, the molded hand phantom was validated with mechanical and OTA tests (maximum error below 1.30 and 1.80 dB for TRP and TIS, respectively). The results demonstrated that using the material with a larger dielectric deviation than the prescribed standard can be used to fabricate hand phantom for predicting the OTA performance. The findings shed light on designing and manufacturing of the hand phantom for in-house research and development purposes.
- 25 August 2021
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Electromagnetic Compatibility
- Vol. 63 (5) , 1699-1708
Predicting Over-the-Air Performance Using a Hand Phantom With Large Dielectric Flexibility
This article developed a hand phantom with a large dielectric deviation from the target values, which can be used to estimate over-the-air (OTA) performance just like the Cellular Telecommunications and Internet Association hand phantom. In this article, the dielectric properties were adjusted by varying the graphite composition in the carbon-loaded silicone. Numerical simulations were used to determine the appropriate material recipe with the aid of the numerical models of four mobile devices operating from 870 to 2700 MHz, using both top and bottom antenna configurations. The results estimated that the material with a difference of 44.65% ± 20.15% (mean ± standard deviation, the maximum value is 77.97%) and 6.79% ± 3.35% (mean ± standard deviation, the maximum value is 9.43%) from the target conductivity and relative permittivity, respectively, provided the maximum deviation of 1.82 dB in the case of total radiated power (TRP) and 1.98 dB for total isotropic sensitivity (TIS). Accordingly, the molded hand phantom was validated with mechanical and OTA tests (maximum error below 1.30 and 1.80 dB for TRP and TIS, respectively). The results demonstrated that using the material with a larger dielectric deviation than the prescribed standard can be used to fabricate hand phantom for predicting the OTA performance. The findings shed light on designing and manufacturing of the hand phantom for in-house research and development purposes.
- Open Access
- 15 June 2021
- Published by EDP Sciences
- Vol. 271, 01033
Simulation of single cell electroporation
This paper attempts to introduce the dynamics of electroporation into the single cell model. The main characteristics of the model were described. Results show the generation and rise of pores in a round cell with a radius of 50 μm exposed to 40 kV/m electric field for 1 ms were analysed, so that the transmembrane potential, the number of pores and the membrane conductance could be calculated. Finally, how the model can help explain the experiment is discussed.
- 15 June 2021
- Published by EDP Sciences
- Vol. 271, 01033
Open AccessSimulation of single cell electroporation
This paper attempts to introduce the dynamics of electroporation into the single cell model. The main characteristics of the model were described. Results show the generation and rise of pores in a round cell with a radius of 50 μm exposed to 40 kV/m electric field for 1 ms were analysed, so that the transmembrane potential, the number of pores and the membrane conductance could be calculated. Finally, how the model can help explain the experiment is discussed.
- Open Access
- 15 June 2021
- Published by EDP Sciences
- Vol. 271, 01032
Conductivity Variation during Irreversible Electroporation
Irreversible electroporation (IRE) is an emerging tumour ablation technique, which utilizes non thermoelectric pulse to ablate tumours. Compared with the common tumour treatment methods, e.g., surgery, chemotherapy and radiotherapy, IRE has advantages of short action time, no massive bleeding of tissue during ablation, avoiding heat sink effect, etc. However, the process of IRE will be affected by the distribution of E-field of the tissue. The major factors which affect E-field distribution are parameters of the electrical pulse and characteristics of the tissue, e.g., the conductivity of the tissue. We utilized the finite element analysis software COMSOL Multiphysics 5.4 to calculate the variation in liver tissue conductivity during IRE. In this study, there is a Low-Voltage High-Frequency (LVHF) pulse involves 3500 unipolar and bipolar pulses, and a High-Voltage Low-Frequency (HVLF) pulse involves eight unipolar and bipolar pulses. The results show that the conductivity change of the HVLF pulse is higher than that of the LVHF pulse due to the higher strength of E-field. The most important conclusion is that the LVHF pulse can only change the tissue conductivity near the electrode tip. The HVLF pulse will significantly change the conductivity in the tissue between the electrodes.
- 15 June 2021
- Published by EDP Sciences
- Vol. 271, 01032
Open AccessConductivity Variation during Irreversible Electroporation
Irreversible electroporation (IRE) is an emerging tumour ablation technique, which utilizes non thermoelectric pulse to ablate tumours. Compared with the common tumour treatment methods, e.g., surgery, chemotherapy and radiotherapy, IRE has advantages of short action time, no massive bleeding of tissue during ablation, avoiding heat sink effect, etc. However, the process of IRE will be affected by the distribution of E-field of the tissue. The major factors which affect E-field distribution are parameters of the electrical pulse and characteristics of the tissue, e.g., the conductivity of the tissue. We utilized the finite element analysis software COMSOL Multiphysics 5.4 to calculate the variation in liver tissue conductivity during IRE. In this study, there is a Low-Voltage High-Frequency (LVHF) pulse involves 3500 unipolar and bipolar pulses, and a High-Voltage Low-Frequency (HVLF) pulse involves eight unipolar and bipolar pulses. The results show that the conductivity change of the HVLF pulse is higher than that of the LVHF pulse due to the higher strength of E-field. The most important conclusion is that the LVHF pulse can only change the tissue conductivity near the electrode tip. The HVLF pulse will significantly change the conductivity in the tissue between the electrodes.
- Open Access
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1861 (1) , 012101
Numerical calculation for effectively simulating the electric field in electroporated tissue
At present, cell membrane perforation technology has been widely used in biology and clinical medicine. Therefore, it is important to master the change pattern of perforated cell membrane potential to further improve the research and application of cell perforation technology. Among them, numerical simulation is an important tool to noninvasively study the effects of tissue properties, electrode arrangement and pulse transmission scheme during electroporation. In this paper, an improved Newton’s method is used to predict pulse voltages and to verify the fit of the method used in this paper for different tissue parameters in a numerical computational model developed specifically for electroporation. The purpose is to improve the reference for researchers to provide faster and more accurate iterative algorithms when studying the electroporation mechanism. The comparative analysis of simulation results between this paper and COMSOL software shows that the method can improve the accuracy of predicting the electric field distribution, reduce the number of iterations, and the effect is well fitted under different tissue parameters. We believe that this knowledge will contribute to a better understanding of in vivo electroporation kinetics and improve electroporation treatment planning techniques.
- 1 March 2021
- Published by IOP Publishing in Journal of Physics: Conference Series
- Vol. 1861 (1) , 012101
Open AccessNumerical calculation for effectively simulating the electric field in electroporated tissue
At present, cell membrane perforation technology has been widely used in biology and clinical medicine. Therefore, it is important to master the change pattern of perforated cell membrane potential to further improve the research and application of cell perforation technology. Among them, numerical simulation is an important tool to noninvasively study the effects of tissue properties, electrode arrangement and pulse transmission scheme during electroporation. In this paper, an improved Newton’s method is used to predict pulse voltages and to verify the fit of the method used in this paper for different tissue parameters in a numerical computational model developed specifically for electroporation. The purpose is to improve the reference for researchers to provide faster and more accurate iterative algorithms when studying the electroporation mechanism. The comparative analysis of simulation results between this paper and COMSOL software shows that the method can improve the accuracy of predicting the electric field distribution, reduce the number of iterations, and the effect is well fitted under different tissue parameters. We believe that this knowledge will contribute to a better understanding of in vivo electroporation kinetics and improve electroporation treatment planning techniques.
- Open Access
- 7 October 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (19) , 3765
Long-Term Monitoring of Extremely Low Frequency Magnetic Fields in Electric Vehicles
Extremely low frequency (ELF) magnetic field (MF) exposure in electric vehicles (EVs) has raised public concern for human health. There have been many studies evaluating magnetic field values in these vehicles. However, there has been no report on the temporal variation of the magnetic field in the cabin. This is the first study on the long-term monitoring of actual MFs in EVs. In the study, we measured the magnetic flux density (B) in three shared vehicles over a period of two years. The measurements were performed at the front and rear seats during acceleration and constant-speed driving modes. We found that the B amplitudes and the spectral components could be modified by replacing the components and the hubs, while regular checks or maintenance did not influence the B values in the vehicle. This observation highlights the necessity of regularly monitoring ELF MF in EVs, especially after major repairs or accidents, to protect car users from potentially excessive ELF MF exposure. These results should be considered in updates of the measurement standards. The ELF MF effect should also be taken into consideration in relevant epidemiological studies.
- 7 October 2019
- Published by MDPI AG in International Journal of Environmental Research and Public Health
- Vol. 16 (19) , 3765
Open AccessLong-Term Monitoring of Extremely Low Frequency Magnetic Fields in Electric Vehicles
Extremely low frequency (ELF) magnetic field (MF) exposure in electric vehicles (EVs) has raised public concern for human health. There have been many studies evaluating magnetic field values in these vehicles. However, there has been no report on the temporal variation of the magnetic field in the cabin. This is the first study on the long-term monitoring of actual MFs in EVs. In the study, we measured the magnetic flux density (B) in three shared vehicles over a period of two years. The measurements were performed at the front and rear seats during acceleration and constant-speed driving modes. We found that the B amplitudes and the spectral components could be modified by replacing the components and the hubs, while regular checks or maintenance did not influence the B values in the vehicle. This observation highlights the necessity of regularly monitoring ELF MF in EVs, especially after major repairs or accidents, to protect car users from potentially excessive ELF MF exposure. These results should be considered in updates of the measurement standards. The ELF MF effect should also be taken into consideration in relevant epidemiological studies.