Ahmad Radan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Ahmad Radan has a total of 5 co-authors. Here are the top co-authors by number of shared publications:
- Arbi Gharakhani
K. N. Toosi University of Technology, Power Electronics Laboratory, Seyed Khandan Bridge, P.O.Box: 16315-1355 Tehran, IRAN Phone: +98 21 8469084, Fax: +98 21 8462066
2 shared publications - A. H. Shahirinia
Power Electronics Laboratory, K.N.Toosi University of Technology, Tehran, Iran
1 shared publication - Alireza Jahangiri
Electrical Engineering Faculty, K.N. Toosi University of Technology, Seyedkhandan Bridge, 1431714191 Tehran, Iran
1 shared publication - Milad Falahi
Electrical Engineering Department, University of Tehran, Tehran, Iran
1 shared publication - Reza Nasiri
Power Electronics Laboratory, Electrical Engineering Faculty, K.N. Toosi University of Technology, Seyed Khandan Bridge, 1431714191 Tehran, Iran
1 shared publication
Latest Publications
- 17 December 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 96, 157-169
Indirect matrix converter with unity voltage transfer ratio for AC to AC power conversion
- 17 December 2012
- Published by Elsevier in Electric Power Systems Research
- Vol. 96, 157-169
Indirect matrix converter with unity voltage transfer ratio for AC to AC power conversion
- 30 August 2010
- Published by Elsevier in Renewable Energy
- Vol. 36 (2) , 858-865
Pole-placement control of 4-leg voltage-source inverters for standalone photovoltaic systems: Considering digital delays
- 30 August 2010
- Published by Elsevier in Renewable Energy
- Vol. 36 (2) , 858-865
Pole-placement control of 4-leg voltage-source inverters for standalone photovoltaic systems: Considering digital delays
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21635137,p. 389-394
Evaluation of Carrier-Based PWM Methods for Multi-level Inverters
Carrier-based methods have been used widely for switching of multilevel inverters due to their simplicity, flexibility and reduced computational requirements compared to space vector modulation (SVM). Several multi-carrier modulation methods with miscellaneous properties have been already known. The paper also proposes another three new multi-carrier techniques being more efficient for high-power inverter applications. While evaluating and comparing these new methods with all basic methods, such as PS, PD, POD and APOD through measures like THD, WTHD, WTHDO, switching losses and DC bus utilization, the paper shows their advantages for applications of diode-clamped and cascade multi-level topologies by simulation results. The validity of obtained results is approved by experimental results.
- 1 June 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- No. 21635137,p. 389-394
Evaluation of Carrier-Based PWM Methods for Multi-level Inverters
Carrier-based methods have been used widely for switching of multilevel inverters due to their simplicity, flexibility and reduced computational requirements compared to space vector modulation (SVM). Several multi-carrier modulation methods with miscellaneous properties have been already known. The paper also proposes another three new multi-carrier techniques being more efficient for high-power inverter applications. While evaluating and comparing these new methods with all basic methods, such as PS, PD, POD and APOD through measures like THD, WTHD, WTHDO, switching losses and DC bus utilization, the paper shows their advantages for applications of diode-clamped and cascade multi-level topologies by simulation results. The validity of obtained results is approved by experimental results.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 748-753
A Novel Strategy for Minimizing the Variation of Neutral Point Voltage and Switching Frequency in DTC Controlled, NPC Driven Induction Motors
Application of the multi-level converters such as neutral point clamped (NPC) inverter for driving the medium voltage induction motors makes more voltage vectors available for a direct torque control (DTC) method and hence more degrees of freedom in selection of voltage vectors when compared to conventional two-level inverter applications. This can be gained for improving inverter performance indices such as variations of neutral point voltage and/or the switching frequency imposed to NPC inverter. This paper propose a convenient strategy for selecting adequate switching states minimizing both the variation of neutral point voltage and the switching frequency of inverter. This helps the designers to increase the power density of inverter and to reduce the size of DC link capacitors resulting in a considerable reduction of drive costs. Simulation results show the effectiveness of the proposed strategy.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 748-753
A Novel Strategy for Minimizing the Variation of Neutral Point Voltage and Switching Frequency in DTC Controlled, NPC Driven Induction Motors
Application of the multi-level converters such as neutral point clamped (NPC) inverter for driving the medium voltage induction motors makes more voltage vectors available for a direct torque control (DTC) method and hence more degrees of freedom in selection of voltage vectors when compared to conventional two-level inverter applications. This can be gained for improving inverter performance indices such as variations of neutral point voltage and/or the switching frequency imposed to NPC inverter. This paper propose a convenient strategy for selecting adequate switching states minimizing both the variation of neutral point voltage and the switching frequency of inverter. This helps the designers to increase the power density of inverter and to reduce the size of DC link capacitors resulting in a considerable reduction of drive costs. Simulation results show the effectiveness of the proposed strategy.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 754-759
Analytical Study of Affecting Characteristic of Voltage Vectors of a Three-level NPC Inverter on Torque and Flux of DTC controlled Drives
The direct torque control (DTC) is known as an effective control method for high performance drives in a wide variety of industrial applications. The objective of this paper is exploration of analytical equations describing the influence of voltage vectors of a space vector modulated neutral point clamped (NPC) Inverter on stator flux and electromagnetic torque variations in medium voltage induction motor drive applications. Using obtained expressions the paper shows that the degrees of freedom of DTC controller is seriously limited by changing the affecting characteristic of some voltage vectors inside the 60deg flux sectors. It proposes therefore the division of flux space vector hexagon into 12, 30deg sectors instead of conventional 60deg ones.
- 1 May 2007
- Published by Institute of Electrical and Electronics Engineers (IEEE)
- Vol. 1, 754-759
Analytical Study of Affecting Characteristic of Voltage Vectors of a Three-level NPC Inverter on Torque and Flux of DTC controlled Drives
The direct torque control (DTC) is known as an effective control method for high performance drives in a wide variety of industrial applications. The objective of this paper is exploration of analytical equations describing the influence of voltage vectors of a space vector modulated neutral point clamped (NPC) Inverter on stator flux and electromagnetic torque variations in medium voltage induction motor drive applications. Using obtained expressions the paper shows that the degrees of freedom of DTC controller is seriously limited by changing the affecting characteristic of some voltage vectors inside the 60deg flux sectors. It proposes therefore the division of flux space vector hexagon into 12, 30deg sectors instead of conventional 60deg ones.