LCLawrence A. Crum

Lawrence A. Crum

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Lawrence A. Crum has a total of 36 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Deep Bleeder Acoustic Coagulation (DBAC)—part II: in vivo testing of a research prototype system

    by K. Michael Sekins, Stephen R. Barnes, Liexiang Fan, Jerry D. Hopple, Stephen J. Hsu, John Kook, Chi-Yin Lee, Caroline Maleke, Xiaozheng (Jenny) Zeng, Romain Moreau-Gobard, et al.

    Deep Bleeder Acoustic Coagulation (DBAC) is an ultrasound image-guided high-intensity focused ultrasound (HIFU) method proposed to automatically detect and localize (D&L) and treat deep, bleeding, combat wounds in the limbs of soldiers. A prototype DBAC system consisting of an applicator and control unit was developed for testing on animals. To enhance control, and thus safety, of the ultimate human DBAC autonomous product system, a thermal coagulation strategy that minimized cavitation, boiling, and non-linear behaviors was used. The in vivo DBAC applicator design had four therapy tiles (Tx) and two 3D (volume) imaging probes (Ix) and was configured to be compatible with a porcine limb bleeder model developed in this research. The DBAC applicator was evaluated under quantitative test conditions (e.g., bleeder depths, flow rates, treatment time limits, and dose exposure time limits) in an in vivo study (final exam) comprising 12 bleeder treatments in three swine. To quantify blood flow rates, the “bleeder” targets were intact arterial branches, i.e., the superficial femoral artery (SFA) and a deep femoral artery (DFA). D&L identified, characterized, and targeted bleeders. The therapy sequence selected Tx arrays and determined the acoustic power and Tx beam steering, focus, and scan patterns. The user interface commands consisted of two buttons: “Start D&L” and “Start Therapy.” Targeting accuracy was assessed by necropsy and histologic exams and efficacy (vessel coagulative occlusion) by angiography and histology. The D&L process (Part I article, J Ther Ultrasound, 2015 (this issue)) executed fully in all cases in under 5 min and targeting evaluation showed 11 of 12 thermal lesions centered on the correct vessel subsection, with minimal damage to adjacent structures. The automated therapy sequence also executed properly, with select manual steps. Because the dose exposure time limit (t dose ≤ 30 s) was associated with nonefficacious treatment, 60-s dosing and dual-dosing was also pursued. Thrombogenic evidence (blood clotting) and collagen denaturation (vessel shrinkage) were found in necropsy and histologically in all targeted SFAs. Acute SFA reductions in blood flow (20–30 %) were achieved in one subject, and one partial and one complete vessel occlusion were confirmed angiographically. The complete occlusion case was achieved with a dual dose (90 s total exposure) with focal intensity ≈500 W/cm2 (spatial average, temporal average). While not meeting all in vivo objectives, the overall performance of the DBAC applicator was positive. In particular, D&L automation workflow was verified during each of the tests, with processing times well under specified (10 min) limits, and all bleeder branches were detected and localized. Further, gross necropsy and tissue examination confirmed that the HIFU thermal lesions were coincident with the target vessel locations in over 90 % of the multi-array dosing treatments. The SFA/DFA bleeder models selected, and the protocols used, were the most suitable practical model options for the given DBAC anatomical and bleeder requirements. The animal models were imperfect in some challenging aspects, including requiring tissue-mimicking material (TMM) standoffs to achieve deep target depths, thereby introducing device-tissue motion, with resultant imaging artifacts. The model “bleeders” involved intact vessels, which are subject to less efficient heating and coagulation cascade behaviors than true puncture injuries.


  • Open Access

    Deep bleeder acoustic coagulation (DBAC)—Part I: development and in vitro testing of a research prototype cuff system

    by K. Michael Sekins, Stephen R. Barnes, Liexiang Fan, Jerry D. Hopple, Stephen J. Hsu, John Kook, Chi-Yin Lee, Caroline Maleke, A R Ramachandran, Xiaozheng (Jenny) Zeng, et al.

    Bleeding from limb injuries is a leading cause of death on the battlefield, with deep wounds being least accessible. High-intensity focused ultrasound (HIFU) has been shown capable of coagulation of bleeding (cautery). This paper describes the development and refereed in vitro evaluation of an ultrasound (US) research prototype deep bleeder acoustic coagulation (DBAC) cuff system for evaluating the potential of DBAC in the battlefield. The device had to meet quantitative performance metrics on automated operation, therapeutic heating, bleeder detection, targeting accuracy, operational time limits, and cuff weight over a range of limb sizes and bleeder depths. These metrics drove innovative approaches in image segmentation, bleeder detection, therapy transducers, beam targeting, and dose monitoring. A companion (Part II) paper discusses the in vivo performance testing of an animal-specific DBAC system. The cuff system employed 3D US imaging probes (“Ix”) for detection and localization (D&L) and targeting, with the bleeders being identified by automated spectral Doppler analysis of flow waveforms. Unique high-element-count therapeutic arrays (“Tx”) were developed, with the final cuff prototype having 21 Tx’s and 6 Ix’s. Spatial registration of Ix’s and Tx’s was done with a combination of image-registration, acoustic time-of-flight measurement, and tracking of the cuff shape via a fiber optic sensor. Acoustic radiation force impulse (ARFI) imaging or thermal strain imaging (TSI) at low-power doses were used to track the HIFU foci in closed-loop targeting. Recurrent neural network (RNN) acoustic thermometry guided closed-loop dosing. The cuff was tested on three phantom “limb” sizes: diameters = 25, 15, and 7.5 cm, with bleeder depths from 3.75 to 12.5 cm. “Integrated Phantoms” (IntP) were used for assessing D&L, closed-loop targeting, and closed-loop dosing. IntPs had surrogate arteries and bleeders, with blood-mimicking fluids moved by a pulsatile pump, and thermocouples (TCs) on the bleeders. Acoustic dosing was developed and tested using “HIFU Phantoms” having precisely located TCs, with end-of-dose target ∆T = 33–58 °C, and skin temperature ∆T ≤ 20 °C, being required. Most DBAC cuff performance requirements were met, including cuff weight, power delivery, targeting accuracy, skin temperature limit, and autonomous operation. The automated D&L completed in 9 of 15 tests (65 %), detecting the smallest (0.6 mm) bleeders, but it had difficulty with the lowest flow (3 cm/sec) bleeders, and in localizing bleeders in the smallest (7.5 cm) phantoms. D&L did not complete within the 9-min limit (results ranged 10–21 min). Closed-loop targeting converged in 20 of 31 tests (71 %), and closed-loop dosing power shut-off at preset ∆Ts was operational. The main performance objectives of the prototype DBAC cuff were met, however the designs required a number of challenging new technology developments. The novel Tx arrays exhibited high power with significant beam steering and focusing flexibility, while their integrated electronics enabled the required compact, lightweight configurability and simplified driving controls and cable/connector architecture. The compounded 3D imaging, combined with sophisticated software algorithms, enabled automated D&L and initial targeting and closed-loop targeting feedback via TSI. The development of RNN acoustic thermometry made possible feedback-controlled dosing. The lightweight architecture required significant design and fabrication effort to meet mechanical functionalities. Although not all target specifications were met, future engineering solutions addressing these performance deficiencies are proposed. Lastly, the program required very complex limb test phantoms and, while very challenging to develop, they performed well.


  • Ultrasonic atomization of tissue and its role in tissue fractionation by high intensity focused ultrasound

    by Julianna C Simon, Oleg A Sapozhnikov, Vera A Khokhlova, Yak-Nam Wang, Lawrence A Crum, Michael R Bailey

    Atomization and fountain formation is a well-known phenomenon that occurs when a focused ultrasound wave in liquid encounters an air interface. High intensity focused ultrasound (HIFU) has been shown to fractionate a tissue into submicron-sized fragments in a process termed boiling histotripsy, wherein the focused ultrasound wave superheats the tissue at the focus, producing a millimetre-sized boiling or vapour bubble in several milliseconds. Yet the question of how this millimetre-sized boiling bubble creates submicron-sized tissue fragments remains. The hypothesis of this work is that the tissue can behave as a liquid such that it atomizes and forms a fountain within the vapour bubble produced in boiling histotripsy. We describe an experiment, in which a 2 MHz HIFU transducer (maximum in situ intensity of 24 000 W cm(-2)) was aligned with an air-tissue interface meant to simulate the boiling bubble. Atomization and fountain formation was observed with high-speed photography and resulted in tissue erosion. Histological examination of the atomized tissue showed whole and fragmented cells and nuclei. Air-liquid interfaces were also filmed. Our conclusion was that HIFU can fountain and atomize tissue. Although this process does not entirely mimic what was observed in liquids, it does explain many aspects of tissue fractionation in boiling histotripsy.


  • Open Access

    Therapeutic ultrasound: Recent trends and future perspectives

    by Lawrence Crum, Michael Bailey, Joo Ha Hwang, Vera Khokhlova, Oleg Sapozhnikov


  • Cinephotographic observations of particle removal from a surface by acoustic cavitation

    by Lawrence A. Crum, Michael R. Bailey, Michael S. Canney, Hong Chen, Thomas Matula, Christopher McInnes

    It is commonly believed that ultrasonic cleaners remove particles from a surface through acoustic cavitation, presumably in which a pulsating bubble interacts directly with the particle. We are unaware of any direct evidence of this interaction. Recently, however, we have used a high-speed movie camera to observe the removal of biofilm attached to a solid surface during exposure to a cavitation field. The biofilm consisted of Streptococcus mutans, a common oral bacterium, grown on a glass slide and observed under magnification to be both thinly coating the glass surface and clustered in larger colonies. The cavitation field was created by an UltreoTM toothbrush which combines both vibrating bristles and an ultrasound transducer with waveguide, operating at a frequency of 324 kHz. When the waveguide was immersed in water containing bubbles from an ultrasound contrast agent (OptisonTM), visual observations could be made with the naked eye of biofilm removal. With high-speed cinephotography, it was possible to observe bacteria removal by the direct interaction of a cavitation bubble (cloud) and the colony. These observations will be presented along with our interpretations of the data. [Work supported in part by UltreoTM, Inc.]

  • Image-Guided Acoustic Therapy

    by Shahram Vaezy, Marilee Andrew, Peter Kaczkowski, Lawrence Crum

    ▪ Abstract The potential role of therapeutic ultrasound in medicine is promising. Currently, medical devices are being developed that utilize high-intensity focused ultrasound as a noninvasive method to treat tumors and to stop bleeding (hemostasis). The primary advantage of ultrasound that lends the technique so readily to use in noninvasive therapy is its ability to penetrate deep into the body and deliver to a specific site thermal or mechanical energy with submillimeter accuracy. Realizing the full potential of acoustic therapy, however, requires precise targeting and monitoring. Fortunately, several imaging modalities can be utilized for this purpose, thus leading to the concept of image-guided acoustic therapy. This article presents a review of high-intensity focused ultrasound therapy, including its mechanisms of action, the imaging modalities used for guidance and monitoring, some current applications, and the requirements and technology associated with this exciting and promising field.