David Wong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
David Wong has a total of 38 co-authors. Here are the top co-authors by number of shared publications:
Ning Cheung
Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Room 301, Level 3, Block B, Cyberport 4, 100 Cyberport Road, Pokfulam, Hong Kong
4 shared publications- Yau Kei Chan
Department of Ophthalmology, Li Ka Shing Faculty of Medicine, University of Hong Kong, Hong Kong, China
3 shared publications Antonia Joussen
Department of Ophthalmology, Charité, University Medicine Berlin, Virchowklinikum (CVK), Berlin, Germany
2 shared publicationsAntonia M. Joussen
Department of Ophthalmology, Charité, University Medicine Berlin, Virchowklinikum (CVK), Berlin, Germany
2 shared publications- Kenneth Kai Wang Li
Department of Ophthalmology, United Christian Hospital, Hospital Authority, Hong Kong SAR, China
2 shared publications - Rachel L. Williams
Department of Eye and Vision Science, Institute of Life Course and Medical Sciences, University of Liverpool, Liverpool, UK
2 shared publications
Latest Publications
- 16 November 2016
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (1) , 15-16
Scleral buckling versus vitrectomy: can the trend be reversed suprachoroidally?
- 16 November 2016
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 255 (1) , 15-16
Scleral buckling versus vitrectomy: can the trend be reversed suprachoroidally?
- Open Access
- 18 September 2015
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 14 (1) , 1-8
Altered myocardial response in patients with diabetic retinopathy: an exercise echocardiography study
Type 2 diabetes mellitus (T2DM) complicated by retinopathy is associated with altered left ventricular (LV) structure and resting myocardial dysfunction unlike T2DM without retinopathy. The myocardial response to stress has not been compared in patients with and without diabetic retinopathy. The aim of this retrospective study was to determine the relationship between retinopathy and myocardial function in patients with T2DM at rest and during exercise echocardiography. 134 patients with T2DM and no evidence of underlying coronary artery disease were recruited. All patients underwent retinal photography to screen for diabetic retinopathy, and resting and exercise echocardiography. Resting echocardiography was analyzed by conventional echocardiographic parameters and speckle tracking derived global longitudinal strain (GLS). Exercise echocardiography parameters included diastolic function reserve index (DFRI) and stress GLS. The mean age of participants was 60 years and 49 % were male. Diabetic retinopathy was identified in 43 patients (32 %). Resting echocardiography revealed that those with diabetic retinopathy had a higher prevalence of impaired diastolic function, higher E/E′ ratio (LV filling pressures) and impaired resting GLS compared with those without. Exercise echocardiography revealed that those with diabetic retinopathy also had more impaired DFRI and stress GLS. Multivariable analysis showed that the presence of diabetic retinopathy was independently associated with high resting E/E′, diastolic dysfunction grade, impaired resting GLS, low DFRI and impaired stress GLS. In conclusion, the presence of diabetic retinopathy was independently associated with impaired resting myocardial function (diastolic and systolic function) and myocardial function during stress (evaluated by DFRI and stress GLS).
- 18 September 2015
- Published by Springer Nature in Cardiovascular Diabetology
- Vol. 14 (1) , 1-8
Open AccessAltered myocardial response in patients with diabetic retinopathy: an exercise echocardiography study
Type 2 diabetes mellitus (T2DM) complicated by retinopathy is associated with altered left ventricular (LV) structure and resting myocardial dysfunction unlike T2DM without retinopathy. The myocardial response to stress has not been compared in patients with and without diabetic retinopathy. The aim of this retrospective study was to determine the relationship between retinopathy and myocardial function in patients with T2DM at rest and during exercise echocardiography. 134 patients with T2DM and no evidence of underlying coronary artery disease were recruited. All patients underwent retinal photography to screen for diabetic retinopathy, and resting and exercise echocardiography. Resting echocardiography was analyzed by conventional echocardiographic parameters and speckle tracking derived global longitudinal strain (GLS). Exercise echocardiography parameters included diastolic function reserve index (DFRI) and stress GLS. The mean age of participants was 60 years and 49 % were male. Diabetic retinopathy was identified in 43 patients (32 %). Resting echocardiography revealed that those with diabetic retinopathy had a higher prevalence of impaired diastolic function, higher E/E′ ratio (LV filling pressures) and impaired resting GLS compared with those without. Exercise echocardiography revealed that those with diabetic retinopathy also had more impaired DFRI and stress GLS. Multivariable analysis showed that the presence of diabetic retinopathy was independently associated with high resting E/E′, diastolic dysfunction grade, impaired resting GLS, low DFRI and impaired stress GLS. In conclusion, the presence of diabetic retinopathy was independently associated with impaired resting myocardial function (diastolic and systolic function) and myocardial function during stress (evaluated by DFRI and stress GLS).
- Open Access
- 26 August 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-4
Is it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
To report a case of late closure of idiopathic full-thickness macular hole (FTMH) after vitrectomy with the inverted internal limiting membrane (ILM) technique. A 68-year-old lady with a stage IV FTMH underwent pars plana vitrectomy with 25 gauge plus transconjunctival system, ILM peeling and gas tamponade. The inverted ILM flap technique was adopted, except that no extra surgical manipulation was used to cover the macular hole with the ILM flap. Surgical outcome was monitored with serial optical coherence tomography (OCT). Complete closure of the FTMH with resolution of intraretinal cystic changes was confirmed on OCT at 16 months postoperatively. Visual acuity improved from a baseline level of 0.1 to 0.4. Idiopathic macular hole closure could be delayed to beyond 1 year following the inverted ILM flap technique, especially if the macular hole was not covered with the ILM flap. Not all macular holes that fail to close in the early postoperative period need to be re-operated and there may be no risk of further visual deterioration.
- 26 August 2015
- Published by Springer Nature in BMC Ophthalmology
- Vol. 15 (1) , 1-4
Open AccessIs it necessary to cover the macular hole with the inverted internal limiting membrane flap in macular hole surgery? A case report
To report a case of late closure of idiopathic full-thickness macular hole (FTMH) after vitrectomy with the inverted internal limiting membrane (ILM) technique. A 68-year-old lady with a stage IV FTMH underwent pars plana vitrectomy with 25 gauge plus transconjunctival system, ILM peeling and gas tamponade. The inverted ILM flap technique was adopted, except that no extra surgical manipulation was used to cover the macular hole with the ILM flap. Surgical outcome was monitored with serial optical coherence tomography (OCT). Complete closure of the FTMH with resolution of intraretinal cystic changes was confirmed on OCT at 16 months postoperatively. Visual acuity improved from a baseline level of 0.1 to 0.4. Idiopathic macular hole closure could be delayed to beyond 1 year following the inverted ILM flap technique, especially if the macular hole was not covered with the ILM flap. Not all macular holes that fail to close in the early postoperative period need to be re-operated and there may be no risk of further visual deterioration.
- 1 December 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (12) , 8453-8457
Flow Behavior of Heavy Silicone Oil During Eye Movements
Purpose:Currently there are various heavy silicone oil (HSO) tamponade agents available for treating inferior retinal diseases. Most of these HSO agents are either a homogeneous liquid or a mixture of two components. Variations in their emulsification rate in-vivo have been reported. In this study, we investigate their flow behaviours during eye-like movements. Methods:A model eye chamber filled with various HSO was driven to perform eye-like movements. Five types of HSO with different formulations together with two other tamponade agents were tested. The movements of various HSO inside the chamber were captured by video recording and analyzed. Results:Oxane HD has a larger movement and higher velocity relative to the eye chamber when compared with the less viscous Densiron® 68. The behaviour of Densiron® 68 is similar to that of the homogeneous HSO 1.07 and HSO 1.20. Both Oxane HD and 11% Silica Fluid show a very different behaviour to the other HSO agents. In addition, 11% Silica Fluid shows a very similar behaviour with F6H8, a low viscosity tamponade agent. Conclusions:The viscosity of HSO is not the sole parameter to determine the behavior of HSO during eye movements. Various HSOs which are manufactured by mixing different types of base SO and "heavy" additives show distinctive flow behaviors. The solubility and the stability of the "heavy" additives in the base SO alter its flow when subjected to eye movements, which may contribute to in-vivo emulsification.
- 1 December 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (12) , 8453-8457
Flow Behavior of Heavy Silicone Oil During Eye Movements
Purpose:Currently there are various heavy silicone oil (HSO) tamponade agents available for treating inferior retinal diseases. Most of these HSO agents are either a homogeneous liquid or a mixture of two components. Variations in their emulsification rate in-vivo have been reported. In this study, we investigate their flow behaviours during eye-like movements. Methods:A model eye chamber filled with various HSO was driven to perform eye-like movements. Five types of HSO with different formulations together with two other tamponade agents were tested. The movements of various HSO inside the chamber were captured by video recording and analyzed. Results:Oxane HD has a larger movement and higher velocity relative to the eye chamber when compared with the less viscous Densiron® 68. The behaviour of Densiron® 68 is similar to that of the homogeneous HSO 1.07 and HSO 1.20. Both Oxane HD and 11% Silica Fluid show a very different behaviour to the other HSO agents. In addition, 11% Silica Fluid shows a very similar behaviour with F6H8, a low viscosity tamponade agent. Conclusions:The viscosity of HSO is not the sole parameter to determine the behavior of HSO during eye movements. Various HSOs which are manufactured by mixing different types of base SO and "heavy" additives show distinctive flow behaviors. The solubility and the stability of the "heavy" additives in the base SO alter its flow when subjected to eye movements, which may contribute to in-vivo emulsification.
- 25 November 2014
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 253 (10) , 1671-1675
Quantifying silicone oil emulsification in patients: are we only seeing the tip of the iceberg?
Emulsification of silicone oil in the eye is a difficult problem. In an effort to find an objective way to quantify emulsification, we used the Coulter principle to measure silicone oil emulsified droplets from the washings of a series of patients.
- 25 November 2014
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 253 (10) , 1671-1675
Quantifying silicone oil emulsification in patients: are we only seeing the tip of the iceberg?
Emulsification of silicone oil in the eye is a difficult problem. In an effort to find an objective way to quantify emulsification, we used the Coulter principle to measure silicone oil emulsified droplets from the washings of a series of patients.
- Open Access
- 1 November 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (11) , 7451-7456
Factors Influencing the Shear Rate Acting on Silicone Oil to Cause Silicone Oil Emulsification
Purpose.: The shear force between silicone oil (SO) bubble and aqueous during eye movements may underlie the development of SO emulsification. This study examines factors that may affect such shear force induced by eye movements. Methods.: A surface-modified model eye chamber was put under large-amplitude eye movements (amplitude 90°, angular velocity 360°/s, and a duration 300 ms). Agarose-made indentations were introduced to mimic the effect of encircling scleral buckle. Two SOs (1300 and 5000 centistokes [cSt]), three volumes (3, 4, and 5 mL), and two eye chambers (with and without indentation) were tested. Video recording was used to capture the movements of SO inside the model chamber under various conditions. Results.: The presence of indentation within the eye chamber significantly reduced the velocity of SO movements relative to the eye chamber movements (P < 0.001). To a lesser extent, an increase in viscosity also had a significant effect in reducing the relative movements. No significant effect was observed for the extent of SO fill in the chamber. Conclusions.: Our experimental model suggests indentation within an eye, such as that created by scleral buckling, may have the greatest influence in reducing shear force induced by eye movements. Therefore, using an encircling scleral buckle may be similarly or more effective than using SO with higher viscosity in lowering the propensity to SO emulsification.
- 1 November 2014
- Published by Association for Research in Vision and Ophthalmology (ARVO) in Investigative Ophthalmology & Visual Science
- Vol. 55 (11) , 7451-7456
Open AccessFactors Influencing the Shear Rate Acting on Silicone Oil to Cause Silicone Oil Emulsification
Purpose.: The shear force between silicone oil (SO) bubble and aqueous during eye movements may underlie the development of SO emulsification. This study examines factors that may affect such shear force induced by eye movements. Methods.: A surface-modified model eye chamber was put under large-amplitude eye movements (amplitude 90°, angular velocity 360°/s, and a duration 300 ms). Agarose-made indentations were introduced to mimic the effect of encircling scleral buckle. Two SOs (1300 and 5000 centistokes [cSt]), three volumes (3, 4, and 5 mL), and two eye chambers (with and without indentation) were tested. Video recording was used to capture the movements of SO inside the model chamber under various conditions. Results.: The presence of indentation within the eye chamber significantly reduced the velocity of SO movements relative to the eye chamber movements (P < 0.001). To a lesser extent, an increase in viscosity also had a significant effect in reducing the relative movements. No significant effect was observed for the extent of SO fill in the chamber. Conclusions.: Our experimental model suggests indentation within an eye, such as that created by scleral buckling, may have the greatest influence in reducing shear force induced by eye movements. Therefore, using an encircling scleral buckle may be similarly or more effective than using SO with higher viscosity in lowering the propensity to SO emulsification.
- 7 October 2014
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 252 (11) , 1695-1696
Graefe’s archive for clinical and experimental ophthalmology—instant glue for retinal detachment surgery?
- 7 October 2014
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 252 (11) , 1695-1696
Graefe’s archive for clinical and experimental ophthalmology—instant glue for retinal detachment surgery?
- 13 September 2014
- Published by Springer Nature
- p. 523-536
IV.F. Pharmacotherapy of Proliferative Vitreoretinopathy
- 13 September 2014
- Published by Springer Nature
- p. 523-536
IV.F. Pharmacotherapy of Proliferative Vitreoretinopathy
- 8 May 2013
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 251 (6) , 1461-1462
No excuse for not looking
- 8 May 2013
- Published by Springer Nature in Graefe's Archive for Clinical and Experimental Ophthalmology
- Vol. 251 (6) , 1461-1462
No excuse for not looking