Shang-Chih Lin
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Shang-Chih Lin has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
- Ching-Shiow Tseng
Department of Mechanical Engineering, National Central University, Taoyuan County 32001, Taiwan
3 shared publications - Chu-An Luo
Graduate Institute of Biomedical Engineering, National Taiwan University of Science and Technology, 43 Keelung Road, Section 4, Taipei, Taiwan
3 shared publications Chun-Ming Chen
High Speed 3D Printing Research Center, National Taiwan University of Science and Technology
3 shared publications- Chun-Ming Chen
Department of Mechanical Engineering, National Central University, Taoyuan, Taiwan
3 shared publications Chi-Pin Hsu
High Speed 3D Printing Research Center, National Taiwan University of Science and Technology
2 shared publicationsChing-Shiow Tseng
Department of Mechanical Engineering, National Central University, No. 300, Jhongda Road, Jhongli City, Taoyuan County32001, Taiwan, R.O.C.
2 shared publications
Latest Publications
- Open Access
- 12 May 2023
- Published byĀ Springer NatureĀ inĀ Research Square
Design Strategies of a Personalized Surgical Instrument to Adjust the Distraction Angle and Posterior Slope for Open Wedge High Tibia Osteotomy Surgery
The precise creation and control of osteotomy and distraction have been a problem in opening wedge high tibial osteotomy (OWHTO). This study aimed to investigate the impact of the cutting edge of a personalized surgical instrument (PSI) to control the distraction angle, tibial slope, and tibial twist of the distracted tibiae. This study correlated the PSI design with the results of biomechanical tests on wedge inclination (WI), saw progression (SP), and distraction site (DS) of the proximal tibiae, which were systematically varied and three-dimensionally (3D) printed as the specimens. The lateral hinge 3D orientation was determined by the WI and SP. Different DSs deviate from the hinged motion of the distracted tibiae to some extent. The coronal angle, which is the major OWHTO target, is more sensitive to the SP and DS. However, the concurrence of the sagittal and horizontal angles induces undesirable effects on knee biomechanics and potentially risks the lateral hinge. The cutting edge is a key design that serves as the cutting and sawing guide to control the initial cut on the medial tibia (i.e., WI) and the sawing path near the lateral cortex (i.e., SP). Intraoperative planning of manipulating the SP is the most effective method for adjusting the sagittal rotation. A higher WI angle is a determinant factor of the horizontal rotation that must be cautiously mitigated to reduce the risk of lateral hinge cracking and to adjust the patellofemoral contact.
- 12 May 2023
- Published byĀ Springer NatureĀ inĀ Research Square
Open AccessDesign Strategies of a Personalized Surgical Instrument to Adjust the Distraction Angle and Posterior Slope for Open Wedge High Tibia Osteotomy Surgery
The precise creation and control of osteotomy and distraction have been a problem in opening wedge high tibial osteotomy (OWHTO). This study aimed to investigate the impact of the cutting edge of a personalized surgical instrument (PSI) to control the distraction angle, tibial slope, and tibial twist of the distracted tibiae. This study correlated the PSI design with the results of biomechanical tests on wedge inclination (WI), saw progression (SP), and distraction site (DS) of the proximal tibiae, which were systematically varied and three-dimensionally (3D) printed as the specimens. The lateral hinge 3D orientation was determined by the WI and SP. Different DSs deviate from the hinged motion of the distracted tibiae to some extent. The coronal angle, which is the major OWHTO target, is more sensitive to the SP and DS. However, the concurrence of the sagittal and horizontal angles induces undesirable effects on knee biomechanics and potentially risks the lateral hinge. The cutting edge is a key design that serves as the cutting and sawing guide to control the initial cut on the medial tibia (i.e., WI) and the sawing path near the lateral cortex (i.e., SP). Intraoperative planning of manipulating the SP is the most effective method for adjusting the sagittal rotation. A higher WI angle is a determinant factor of the horizontal rotation that must be cautiously mitigated to reduce the risk of lateral hinge cracking and to adjust the patellofemoral contact.
- 5 February 2017
- Published byĀ IOP PublishingĀ inĀ Medical Engineering & Physics
- Vol.Ā 42 Ā (1) , 48-54
The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: A finite element study
Several plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.e., cortical) screw through the proximal combi-hole, to deform the plate and pull the distal tibia toward the plate. This process potentially induces plate springback and creates an elastic preload on the osteotomized tibia, especially at the lateral hinge of the distracted wedge. Using the finite-element method, this study aims to investigate the contoured effect of lag-screw application on the biomechanical behavior of the tibia-plate construct. Two tibial profiles (normal and more concave), three distraction angles (6°, 9°, and 12°), and three knee loads (intraoperative: contouring plate; postoperative: weight and nonweight bearing) are systematically varied in this study. The wedge instability and fracture risk at the lateral hinge are chosen as the comparison indices. The results show the necessity of preoperative planning for a precontoured procedure, rather than elastic deformation using a lag screw. Within the intraoperative period, a more concave tibial profile and/or reduced distraction angle (i.e., 6° or 9°) necessitate a higher compressive load to elastically deform the plate, thereby deteriorating the lateral-hinge fracture risk. A precontoured plate is recommended in the case that the proximal tibia is highly concave and the distraction angle is insufficient to stretch the tibial profile.
- 5 February 2017
- Published byĀ IOP PublishingĀ inĀ Medical Engineering & Physics
- Vol.Ā 42 Ā (1) , 48-54
The effects of tibia profile, distraction angle, and knee load on wedge instability and hinge fracture: A finite element study
Several plate systems for high tibial osteotomy (HTO) have been developed to stabilize the opening wedge of an osteotomized tibia. Among them, the TomoFix system, having a quasi-straight and T-shaped design, has been widely adopted in the literature. However, this system is implemented by inserting a lag (i.e., cortical) screw through the proximal combi-hole, to deform the plate and pull the distal tibia toward the plate. This process potentially induces plate springback and creates an elastic preload on the osteotomized tibia, especially at the lateral hinge of the distracted wedge. Using the finite-element method, this study aims to investigate the contoured effect of lag-screw application on the biomechanical behavior of the tibia-plate construct. Two tibial profiles (normal and more concave), three distraction angles (6°, 9°, and 12°), and three knee loads (intraoperative: contouring plate; postoperative: weight and nonweight bearing) are systematically varied in this study. The wedge instability and fracture risk at the lateral hinge are chosen as the comparison indices. The results show the necessity of preoperative planning for a precontoured procedure, rather than elastic deformation using a lag screw. Within the intraoperative period, a more concave tibial profile and/or reduced distraction angle (i.e., 6° or 9°) necessitate a higher compressive load to elastically deform the plate, thereby deteriorating the lateral-hinge fracture risk. A precontoured plate is recommended in the case that the proximal tibia is highly concave and the distraction angle is insufficient to stretch the tibial profile.
- Open Access
- 4 September 2015
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 16 Ā (1) , 235
Placement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses
High tibial osteotomy (HTO) with a medially opening wedge has been used to treat osteoarthritic knees. However, the osteotomized tibia becomes a highly unstable structure and necessitates the use of plate and screws to stabilize the medial opening and enhance bone healing. A T-shaped plate (e.g. TomoFix) with locking screws has been extensively used as a stabilizer of the HTO wedge. From the biomechanical viewpoint, however, the different plate sites and support bases of the HTO plate should affect the load-transferring path and wedge-stabilizing ability of the HTO construct. This study uses biomechanical tests and finite-element analyses to evaluate the placement- and base-induced effects of the HTO plates on construct performance. Test-grade synthetic tibiae are chosen as the standard specimens of the static tests. A medial wedge is created for each specimen and stabilized by three plate variations: hybrid use of T- and I-shaped plates (TIP), anteriorly placed TomoFix (APT), and medially placed TomoFix (MPT). There are five tests for each variation. The failure loads of the three constructs are measured and used as the load references of the fatigue finite-element analysis. The residual life after two hundred thousand cycles is predicted for all variations. The testing results show no occurrence of implant back-out and breakage under all variations. However, the wedge fracture consistently occurs at the opening tip for the APT and MPT and the medially resected plateau for the TIP, respectively. The testing results reveal that both failure load and wedge stiffness of the TIP are the highest, followed by the MPT, while those of the APT are the least (P < 0.05). The fatigue analyses predict comparable values of residual life for the TIP and MPT and the highest value of damage accumulation for the APT. Both experimental and numerical tests show the biomechanical disadvantage of the APT than their counterparts. However, the TIP construct without locking screws shows the highest stress at the plate-screw interfaces. This study demonstrates the significant effect of placement site and support base on the construct behaviors. The TIP provides a wider base for supporting the HTO wedge even without the use of locking screws, thus significantly enhancing construct stiffness and suppressing wedge fracture. Compared to the APT, the MPT shows performance more comparable to that of the TIP. If a single plate and a smaller incision are considered, the MPT is recommended as the better alternative for stabilizing the medial HTO wedge.
- 4 September 2015
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 16 Ā (1) , 235
Open AccessPlacement-induced effects on high tibial osteotomized construct - biomechanical tests and finite-element analyses
High tibial osteotomy (HTO) with a medially opening wedge has been used to treat osteoarthritic knees. However, the osteotomized tibia becomes a highly unstable structure and necessitates the use of plate and screws to stabilize the medial opening and enhance bone healing. A T-shaped plate (e.g. TomoFix) with locking screws has been extensively used as a stabilizer of the HTO wedge. From the biomechanical viewpoint, however, the different plate sites and support bases of the HTO plate should affect the load-transferring path and wedge-stabilizing ability of the HTO construct. This study uses biomechanical tests and finite-element analyses to evaluate the placement- and base-induced effects of the HTO plates on construct performance. Test-grade synthetic tibiae are chosen as the standard specimens of the static tests. A medial wedge is created for each specimen and stabilized by three plate variations: hybrid use of T- and I-shaped plates (TIP), anteriorly placed TomoFix (APT), and medially placed TomoFix (MPT). There are five tests for each variation. The failure loads of the three constructs are measured and used as the load references of the fatigue finite-element analysis. The residual life after two hundred thousand cycles is predicted for all variations. The testing results show no occurrence of implant back-out and breakage under all variations. However, the wedge fracture consistently occurs at the opening tip for the APT and MPT and the medially resected plateau for the TIP, respectively. The testing results reveal that both failure load and wedge stiffness of the TIP are the highest, followed by the MPT, while those of the APT are the least (P < 0.05). The fatigue analyses predict comparable values of residual life for the TIP and MPT and the highest value of damage accumulation for the APT. Both experimental and numerical tests show the biomechanical disadvantage of the APT than their counterparts. However, the TIP construct without locking screws shows the highest stress at the plate-screw interfaces. This study demonstrates the significant effect of placement site and support base on the construct behaviors. The TIP provides a wider base for supporting the HTO wedge even without the use of locking screws, thus significantly enhancing construct stiffness and suppressing wedge fracture. Compared to the APT, the MPT shows performance more comparable to that of the TIP. If a single plate and a smaller incision are considered, the MPT is recommended as the better alternative for stabilizing the medial HTO wedge.
- Open Access
- 26 September 2014
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 15 Ā (1) , 312
Effects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant
Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. In this study, the finite-element models of one intact, one stemmed, and two nonstemmed femora with minimal removal of the healthy neck were investigated to evaluate their biomechanical effects. The resurfacing (ball-shaped) and fitting (neck-shaped) systems were respectively selected as the representative of the ready- and custom-made nonstemmed implants. The stress distribution and interface micromotion were selected as the comparison indices. The results showed that stress distributions of the two nonstemmed femora are consistently more similar to the intact femur than the stemmed one. Around the proximal femur, the stem definitely induces the stress-shielding phenomenon of its counterparts. The fitting system with the anatomy-shaped cup can make intimate contact with the neck cortex and reduce the bone-cup micromotion and the implant stress. Comparatively, the reamed femoral head provides weaker support to the resurfacing cup causing higher interfacial micromotion. The reserved femoral neck could act as the load-transferring medium from the acetabular cup, femoral neck, to the diaphysial bone, thus depressing the stress-shielding effect below the neck region. If the hip-cup construct can be definitely stabilized, the nonstemmed design could be an alternative of hip arthroplasty for the younger or the specific patients with the disease limited only to the femoral head.
- 26 September 2014
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 15 Ā (1) , 312
Open AccessEffects of stemmed and nonstemmed hip replacement on stress distribution of proximal femur and implant
Despite improvements in shape, material, and coating for hip stem, both stress shielding and aseptic loosening have been the major drawbacks of stemmed hip arthroplasty. Some nonstemmed systems were developed to avoid rasping off the intramedullary canal and evacuating the bone marrow due to stem insertion. In this study, the finite-element models of one intact, one stemmed, and two nonstemmed femora with minimal removal of the healthy neck were investigated to evaluate their biomechanical effects. The resurfacing (ball-shaped) and fitting (neck-shaped) systems were respectively selected as the representative of the ready- and custom-made nonstemmed implants. The stress distribution and interface micromotion were selected as the comparison indices. The results showed that stress distributions of the two nonstemmed femora are consistently more similar to the intact femur than the stemmed one. Around the proximal femur, the stem definitely induces the stress-shielding phenomenon of its counterparts. The fitting system with the anatomy-shaped cup can make intimate contact with the neck cortex and reduce the bone-cup micromotion and the implant stress. Comparatively, the reamed femoral head provides weaker support to the resurfacing cup causing higher interfacial micromotion. The reserved femoral neck could act as the load-transferring medium from the acetabular cup, femoral neck, to the diaphysial bone, thus depressing the stress-shielding effect below the neck region. If the hip-cup construct can be definitely stabilized, the nonstemmed design could be an alternative of hip arthroplasty for the younger or the specific patients with the disease limited only to the femoral head.
- 1 June 2014
- Published byĀ Wolters Kluwer HealthĀ inĀ Spine
- Vol.Ā 39 Ā (13) , E770-E776
Biomechanical Effects of Cage Positions and Facet Fixation on Initial Stability of the Anterior Lumbar Interbody Fusion Motion Segment
Study Design. An in vitro biomechanical study using porcine lumbar segments as specimens. Objective. To evaluate the effects of interbody cage support and endplate strength on the stability of instrumented segments. Summary of Background Data. The anterior lumbar interbody fusion (ALIF) cage is widely used to restore disc height and support the anterior column. Transpedicle or posterior spinal fusion or facet screw fixation (FSF) can improve the stability of the vertebra-instrumented segments. The cage position can affect the anterior support and initial stability of the ALIF region, but there is no consistent data on its biomechanical effects on ALIF and ALIF/FSF segments. Methods. Nine variations of 3 instrumentation modes (intact, ALIF, ALIF/FSF) and 3 cage positions (type I, anterolateral; type II, mediolateral; and type III, posteromedial) are tested under 5 lumbar motions. The range of motion and axial displacement are used as comparison indices for the different variations. Results. The cage placement serves as support for the intervertebral loads while the posterior fixation behaves as lever to further enhance the anterior support. At the endplate-cage interfaces, the endplate strength directly affects the cage subsidence. Type III exhibits higher stability for standing due to the greater strength of the endplate in the posterior region. Otherwise, type I consistently has higher stability for all other types of motion. Conclusion. The initial stability of the ALIF region is affected by the moment arm and the mechanical strength of the engaged endplates. Type I has greater moment arm and provides more efficient support to the instrumented segments. Endplate strength provides an ability to withstand lumbar loads and suppress the cage subsidence. Bone quality at the endplate-cage interfaces must therefore be cautiously evaluated preoperatively. Level of Evidence: N/A
- 1 June 2014
- Published byĀ Wolters Kluwer HealthĀ inĀ Spine
- Vol.Ā 39 Ā (13) , E770-E776
Biomechanical Effects of Cage Positions and Facet Fixation on Initial Stability of the Anterior Lumbar Interbody Fusion Motion Segment
Study Design. An in vitro biomechanical study using porcine lumbar segments as specimens. Objective. To evaluate the effects of interbody cage support and endplate strength on the stability of instrumented segments. Summary of Background Data. The anterior lumbar interbody fusion (ALIF) cage is widely used to restore disc height and support the anterior column. Transpedicle or posterior spinal fusion or facet screw fixation (FSF) can improve the stability of the vertebra-instrumented segments. The cage position can affect the anterior support and initial stability of the ALIF region, but there is no consistent data on its biomechanical effects on ALIF and ALIF/FSF segments. Methods. Nine variations of 3 instrumentation modes (intact, ALIF, ALIF/FSF) and 3 cage positions (type I, anterolateral; type II, mediolateral; and type III, posteromedial) are tested under 5 lumbar motions. The range of motion and axial displacement are used as comparison indices for the different variations. Results. The cage placement serves as support for the intervertebral loads while the posterior fixation behaves as lever to further enhance the anterior support. At the endplate-cage interfaces, the endplate strength directly affects the cage subsidence. Type III exhibits higher stability for standing due to the greater strength of the endplate in the posterior region. Otherwise, type I consistently has higher stability for all other types of motion. Conclusion. The initial stability of the ALIF region is affected by the moment arm and the mechanical strength of the engaged endplates. Type I has greater moment arm and provides more efficient support to the instrumented segments. Endplate strength provides an ability to withstand lumbar loads and suppress the cage subsidence. Bone quality at the endplate-cage interfaces must therefore be cautiously evaluated preoperatively. Level of Evidence: N/A
- 11 March 2014
- Published byĀ Taylor & FrancisĀ inĀ Computer Methods in Biomechanics and Biomedical Engineering
- Vol.Ā 18 Ā (12) , 1263-1271
Biomechanical effects of plate area and locking screw on medial open tibial osteotomy
Medial open high tibial osteotomy (HTO) has been used to treat osteoarthritis of the medial compartment of the knee. However, weaker plate strength, unstable plate/screw junction and improper surgery technique are highly related to the HTO outcomes. Two Ļ-shape plates were designed and eight variations (two supporting area Ć four locking stiffness) were compared by finite-element method. The computed tomography-based tibia was reconstructed and both wedge micromotion and implant stresses were chosen as the comparison indices. The construct was subjected to surgical and physiological loads. The medial-posterior region is the most loaded region and the load through the posterior leg is about four times that through the anterior leg. This indicates that the two-leg design can form a force-couple mechanism to effectively reduce the implant stresses. The use of locking screws significantly decrease the screw and hole stresses. However, the extending plate reduces the stresses of screws and holes above the wedge but makes the distal screws and holes much stressed. Wedge micromotion is affected by extending plate rather than locking screw. Three factors contribute to effective stabilisation of unstable HTO wedge: (1) intimate tibiaāplate contact at medial-posterior regions, (2) sufficient rigidity at plate-screw junctions and (3) effective moment-balancing design at distal tibiaāplate interfaces.
- 11 March 2014
- Published byĀ Taylor & FrancisĀ inĀ Computer Methods in Biomechanics and Biomedical Engineering
- Vol.Ā 18 Ā (12) , 1263-1271
Biomechanical effects of plate area and locking screw on medial open tibial osteotomy
Medial open high tibial osteotomy (HTO) has been used to treat osteoarthritis of the medial compartment of the knee. However, weaker plate strength, unstable plate/screw junction and improper surgery technique are highly related to the HTO outcomes. Two Ļ-shape plates were designed and eight variations (two supporting area Ć four locking stiffness) were compared by finite-element method. The computed tomography-based tibia was reconstructed and both wedge micromotion and implant stresses were chosen as the comparison indices. The construct was subjected to surgical and physiological loads. The medial-posterior region is the most loaded region and the load through the posterior leg is about four times that through the anterior leg. This indicates that the two-leg design can form a force-couple mechanism to effectively reduce the implant stresses. The use of locking screws significantly decrease the screw and hole stresses. However, the extending plate reduces the stresses of screws and holes above the wedge but makes the distal screws and holes much stressed. Wedge micromotion is affected by extending plate rather than locking screw. Three factors contribute to effective stabilisation of unstable HTO wedge: (1) intimate tibiaāplate contact at medial-posterior regions, (2) sufficient rigidity at plate-screw junctions and (3) effective moment-balancing design at distal tibiaāplate interfaces.
- 1 February 2014
- Published byĀ ElsevierĀ inĀ Clinical Biomechanics
- Vol.Ā 29 Ā (2) , 161-169
Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system
- 1 February 2014
- Published byĀ ElsevierĀ inĀ Clinical Biomechanics
- Vol.Ā 29 Ā (2) , 161-169
Biomechanical effects of bone-implant fitness and screw breakage on the stability and stress performance of the nonstemmed hip system
- Open Access
- 25 March 2013
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 14 Ā (1) , 110
Stress and stability comparison between different systems for high tibial osteotomies
Background: High tibial osteotomy (HTO) with a medial opening wedge has been used to treat medial compartment osteoarthritis. However, this makes the proximal tibia a highly unstable structure and causes plate and screws to be the potentials sources for mechanical failure. Consequently, proper design and use of the fixation device are essential to the HTO especially for overweight or full weight-bearing patients.Methods: Based on the CT-based images, a tibial finite-element model with medial opening was simulated and instrumented with one-leg and two-leg plate systems. The construct was subjected to physiological and surgical loads. Construct stresses and wedge micromotions were chosen as the comparison indices.Results: The use of locking screws can stabilize the construct and decrease the implant and bone stresses. Comparatively, the two-leg design provides a wider load-sharing base to form a force-couple mechanism that effectively reduces construct stresses and wedge micromotions. However, the incision size, muscular stripping, and structural rigidity are the major concerns of using the two-leg systems. The one-leg plates behave as the fulcrum of the leverage system and make the wedge tip the zone of tension and thus have been reported to negatively affect the callus formation.Conclusions: The choice of the HTO plates involved the trade-off between surgical convenience, construct stability, and stress-shielding effect. If the stability of the medial opening is the major concern, the two-leg system is suggested for the patients with heavy load demands and greater proximal tibial size. The one-leg system with locking screws can be used for the majority of the patients without heavy bodyweight and poor bone quality.
- 25 March 2013
- Published byĀ Springer NatureĀ inĀ BMC Musculoskeletal Disorders
- Vol.Ā 14 Ā (1) , 110
Open AccessStress and stability comparison between different systems for high tibial osteotomies
Background: High tibial osteotomy (HTO) with a medial opening wedge has been used to treat medial compartment osteoarthritis. However, this makes the proximal tibia a highly unstable structure and causes plate and screws to be the potentials sources for mechanical failure. Consequently, proper design and use of the fixation device are essential to the HTO especially for overweight or full weight-bearing patients.Methods: Based on the CT-based images, a tibial finite-element model with medial opening was simulated and instrumented with one-leg and two-leg plate systems. The construct was subjected to physiological and surgical loads. Construct stresses and wedge micromotions were chosen as the comparison indices.Results: The use of locking screws can stabilize the construct and decrease the implant and bone stresses. Comparatively, the two-leg design provides a wider load-sharing base to form a force-couple mechanism that effectively reduces construct stresses and wedge micromotions. However, the incision size, muscular stripping, and structural rigidity are the major concerns of using the two-leg systems. The one-leg plates behave as the fulcrum of the leverage system and make the wedge tip the zone of tension and thus have been reported to negatively affect the callus formation.Conclusions: The choice of the HTO plates involved the trade-off between surgical convenience, construct stability, and stress-shielding effect. If the stability of the medial opening is the major concern, the two-leg system is suggested for the patients with heavy load demands and greater proximal tibial size. The one-leg system with locking screws can be used for the majority of the patients without heavy bodyweight and poor bone quality.
- 15 November 2012
- Published byĀ Wolters Kluwer HealthĀ inĀ Spine
- Vol.Ā 37 Ā (24) , E1488-E1497
Biomechanical Effects of Disc Degeneration and Hybrid Fixation on the Transition and Adjacent Lumbar Segments
Study Design. The biomechanical effects of disc degeneration and hybrid fixation on the transition and adjacent segments were evaluated using a numerical approach. Objective. This study aimed to evaluate the rigidity-rising effects of the dehydrated disc and bridged fixator on the kinematic and mechanical redistribution of the transition and adjacent segments. Summary of Background Data. After static fixation, a dynamic fixator can be used to preserve motion and share loads for the transition segments. However, the hybrid use of both static and dynamic fixators and its effects on the biomechanical behavior of the transition and adjacent segments were not investigated extensively. Methods. A nonlinear and osseoligamentous lumbar model from L1 vertebra to S1 vertebrae was developed. Ligament interconnection, muscular contraction, and weight compression were all used to simulate lumbar flexion. The static fixator was instrumented at the degenerative L4āL5 segment and the dynamic fixators (Dynesys system) with different stiffness were subsequently applied to the degenerative or healthy L3āL4 segment. A healthy lumbar model was used as a reference point for further comparison and evaluation. The predicted results were validated with the cadaveric and numerical values of the literature studies. Among the 21 models, the junctional problem at the adjacent (L2/L3 and L5/S1) discs as well as the motion preservation and stress distribution at the transition (L3/L4) disc were compared. Results. Static fixation and the degenerative disc deteriorated the junctional problem at adjacent segments. On average, the hybrid fixation of the original Dynesys cord constrained the range of motion (ROM) by 65%. Furthermore, it shared 43% of the stress on the transition disc. However, this resulted in the adjacent discs increasing about 50% ROM and 40% stress. The term ātrade-off stiffnessā was used to express the concept that the decreased stiffness of the original cord could balance the junctional problem, motion preservation, and load protection of the transition and adjacent segments. The trade-off stiffness of the degenerative transition disc was higher than that of the healthy disc. Compared with the original design, the increased ROM and stress of the adjacent segments can be reduced by about 43% using the trade-off stiffness. Conclusion. The use of the hybrid fixator should involve a certain trade-off between the protection of the transition segment and the deterioration of the adjacent segments. This trade-off stiffness, which largely depends on both fixator design and disc degeneration, provides the improved rigidity and flexibility of the transition and adjacent segments.
- 15 November 2012
- Published byĀ Wolters Kluwer HealthĀ inĀ Spine
- Vol.Ā 37 Ā (24) , E1488-E1497
Biomechanical Effects of Disc Degeneration and Hybrid Fixation on the Transition and Adjacent Lumbar Segments
Study Design. The biomechanical effects of disc degeneration and hybrid fixation on the transition and adjacent segments were evaluated using a numerical approach. Objective. This study aimed to evaluate the rigidity-rising effects of the dehydrated disc and bridged fixator on the kinematic and mechanical redistribution of the transition and adjacent segments. Summary of Background Data. After static fixation, a dynamic fixator can be used to preserve motion and share loads for the transition segments. However, the hybrid use of both static and dynamic fixators and its effects on the biomechanical behavior of the transition and adjacent segments were not investigated extensively. Methods. A nonlinear and osseoligamentous lumbar model from L1 vertebra to S1 vertebrae was developed. Ligament interconnection, muscular contraction, and weight compression were all used to simulate lumbar flexion. The static fixator was instrumented at the degenerative L4āL5 segment and the dynamic fixators (Dynesys system) with different stiffness were subsequently applied to the degenerative or healthy L3āL4 segment. A healthy lumbar model was used as a reference point for further comparison and evaluation. The predicted results were validated with the cadaveric and numerical values of the literature studies. Among the 21 models, the junctional problem at the adjacent (L2/L3 and L5/S1) discs as well as the motion preservation and stress distribution at the transition (L3/L4) disc were compared. Results. Static fixation and the degenerative disc deteriorated the junctional problem at adjacent segments. On average, the hybrid fixation of the original Dynesys cord constrained the range of motion (ROM) by 65%. Furthermore, it shared 43% of the stress on the transition disc. However, this resulted in the adjacent discs increasing about 50% ROM and 40% stress. The term ātrade-off stiffnessā was used to express the concept that the decreased stiffness of the original cord could balance the junctional problem, motion preservation, and load protection of the transition and adjacent segments. The trade-off stiffness of the degenerative transition disc was higher than that of the healthy disc. Compared with the original design, the increased ROM and stress of the adjacent segments can be reduced by about 43% using the trade-off stiffness. Conclusion. The use of the hybrid fixator should involve a certain trade-off between the protection of the transition segment and the deterioration of the adjacent segments. This trade-off stiffness, which largely depends on both fixator design and disc degeneration, provides the improved rigidity and flexibility of the transition and adjacent segments.
- 16 July 2012
- Published byĀ SAGE PublicationsĀ inĀ Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol.Ā 226 Ā (10) , 776-786
Biomechanical influence of pin placement and elbow angle on joint distraction and hinge alignment for an arthrodiatasis elbowāpināfixator construct
Stiffness and contracture of the periarticular tissues are common complications of a post-traumatic elbow. Arthrodiatasis is a surgical technique that uses an external fixator for initial immobilization and subsequent distraction. The two prerequisites for an ideal arthrodiatasis are concentric distraction (avoiding bony contact) and hinge alignment (reducing internal stress). This study used the finite element (FE) method to clarify the relationship between these two prerequisites and the initial conditions (pin placement, elbow angle, and distraction mode). A total of 12 variations of the initial conditions were symmetrically arranged to evaluate their biomechanical influence on concentric distraction and hinge alignment. The humeroulnar surface was hypothesized to be ideally distracted orthogonal to the line joining the tips of the olecranon and the coronoid. The eccentric separation of the humeroulnar surfaces is a response to the non-orthogonality of the distracting force and joining line. Pin placement significantly affects the effective moment arm of the fixing pins to distract the bridged elbow. Both elbow angle and distraction mode directly alter the direction of the distracting force at the elbow center. In general, the hinges misalignment occurs in a direction opposite to the distraction-activated site. After joint distraction, the elastic deflection of the fixing pins inevitably makes both elbow and fixator hinges to misalign. This indicates that both joint distraction and hinge alignment are the interactive mechanisms. The humeroulnar separation is more concentric in the situation of the 120° humeral distraction by using stiffer pins with convergent placement. Even so, the eccentric displacement of the elbow hinge is a crucial consideration in the initial placement of the guiding pin to compensate for hinge misalignment.
- 16 July 2012
- Published byĀ SAGE PublicationsĀ inĀ Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine
- Vol.Ā 226 Ā (10) , 776-786
Biomechanical influence of pin placement and elbow angle on joint distraction and hinge alignment for an arthrodiatasis elbowāpināfixator construct
Stiffness and contracture of the periarticular tissues are common complications of a post-traumatic elbow. Arthrodiatasis is a surgical technique that uses an external fixator for initial immobilization and subsequent distraction. The two prerequisites for an ideal arthrodiatasis are concentric distraction (avoiding bony contact) and hinge alignment (reducing internal stress). This study used the finite element (FE) method to clarify the relationship between these two prerequisites and the initial conditions (pin placement, elbow angle, and distraction mode). A total of 12 variations of the initial conditions were symmetrically arranged to evaluate their biomechanical influence on concentric distraction and hinge alignment. The humeroulnar surface was hypothesized to be ideally distracted orthogonal to the line joining the tips of the olecranon and the coronoid. The eccentric separation of the humeroulnar surfaces is a response to the non-orthogonality of the distracting force and joining line. Pin placement significantly affects the effective moment arm of the fixing pins to distract the bridged elbow. Both elbow angle and distraction mode directly alter the direction of the distracting force at the elbow center. In general, the hinges misalignment occurs in a direction opposite to the distraction-activated site. After joint distraction, the elastic deflection of the fixing pins inevitably makes both elbow and fixator hinges to misalign. This indicates that both joint distraction and hinge alignment are the interactive mechanisms. The humeroulnar separation is more concentric in the situation of the 120° humeral distraction by using stiffer pins with convergent placement. Even so, the eccentric displacement of the elbow hinge is a crucial consideration in the initial placement of the guiding pin to compensate for hinge misalignment.