Mio Nakamoto
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Mio Nakamoto has a total of 129 co-authors. Here are the top co-authors by number of shared publications:
- Masataka Nakahira
QST, Naka, Ibaraki, JAPAN
9 shared publications - Norikiyo Koizumi
QST Naka, Ibaraki, Japan
9 shared publications - Hideki Kajitani
National Institutes for Quantum Science and Technology
8 shared publications - Kunihiro Matsui
QST, Naka, Ibaraki Japan
6 shared publications - K. Gomikawa
ITER Organization (IO), St. Paul lez Durance, France
3 shared publications - Masahide Iguchi
National Institutes for Quantum and Radiological Science and Technology
3 shared publications
Latest Publications
- Open Access
- 25 April 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (6) , 066010
Lessons learned from European and Japanese production of ITER toroidal field coils
In 2023, the manufacturing of all the ITER TF coils has been completed 15 years after the sign of procurement arrangements in 2008. This paper has been jointly submitted by F4E and QST to recollect the lessons learnt in the production of the two parties along the last 15 years.
- 25 April 2024
- Published by IOP Publishing in Nuclear Fusion
- Vol. 64 (6) , 066010
Open AccessLessons learned from European and Japanese production of ITER toroidal field coils
In 2023, the manufacturing of all the ITER TF coils has been completed 15 years after the sign of procurement arrangements in 2008. This paper has been jointly submitted by F4E and QST to recollect the lessons learnt in the production of the two parties along the last 15 years.
- Open Access
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Internal Strain Measurement by Neutron Diffraction Under Transverse Compressive Stress for Nb3Sn Wires With and Without Cu-Nb Reinforcement
For an accelerator magnet, a certain mechanical strength is required to sustain against a transverse compression stress due to Lorentz force. A bronze-route Nb 3 Sn wire with Cu-Nb reinforcement was developed by Tohoku University and Furukawa Electric to enhance the strength against axial tension. The Cu-Nb reinforcement wire also exhibited some indication of strength improvement against transverse compression; however, the details of a reinforcement mechanism for the transverse compression stress have not been clarified. In this study, the internal strains of Nb 3 Sn bronze-route wires with and without the Cu-Nb reinforcement under transverse compression stress were evaluated by neutron diffraction at BL19 (TAKUMI) in J-PARC. The samples were attached to jig with solder only at the ends and compression was applied at the center of the samples with 30-mm anvil with 5-mm wide and 8- to 15-mm high beam. Since a critical current, Ic of a superconducting wire depends on the three-dimensional strain, internal strain of Nb 3 Sn along the axial and two orthogonal radial directions were evaluated at room temperature (RT). In the different setup, Ic measurements of the wires under transverse compression stresses were also performed at 4.2 K and 14.5 T. Using 3-mm wide anvil, the transverse compression was applied at 4.2 K or RT. The neutron diffraction results indicated no significant differences in the internal strains of Nb 3 Sn under transverse compression between the samples with and without Cu-Nb reinforcement, while the Ic measurements showed potential increase in the irreversible stress ( σirr ) for Cu-Nb reinforced wires. The reason for this discrepancy was discussed based on the difference in the experimental setups for each measurement.
- 19 March 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-6
Open AccessInternal Strain Measurement by Neutron Diffraction Under Transverse Compressive Stress for Nb3Sn Wires With and Without Cu-Nb Reinforcement
For an accelerator magnet, a certain mechanical strength is required to sustain against a transverse compression stress due to Lorentz force. A bronze-route Nb 3 Sn wire with Cu-Nb reinforcement was developed by Tohoku University and Furukawa Electric to enhance the strength against axial tension. The Cu-Nb reinforcement wire also exhibited some indication of strength improvement against transverse compression; however, the details of a reinforcement mechanism for the transverse compression stress have not been clarified. In this study, the internal strains of Nb 3 Sn bronze-route wires with and without the Cu-Nb reinforcement under transverse compression stress were evaluated by neutron diffraction at BL19 (TAKUMI) in J-PARC. The samples were attached to jig with solder only at the ends and compression was applied at the center of the samples with 30-mm anvil with 5-mm wide and 8- to 15-mm high beam. Since a critical current, Ic of a superconducting wire depends on the three-dimensional strain, internal strain of Nb 3 Sn along the axial and two orthogonal radial directions were evaluated at room temperature (RT). In the different setup, Ic measurements of the wires under transverse compression stresses were also performed at 4.2 K and 14.5 T. Using 3-mm wide anvil, the transverse compression was applied at 4.2 K or RT. The neutron diffraction results indicated no significant differences in the internal strains of Nb 3 Sn under transverse compression between the samples with and without Cu-Nb reinforcement, while the Ic measurements showed potential increase in the irreversible stress ( σirr ) for Cu-Nb reinforced wires. The reason for this discrepancy was discussed based on the difference in the experimental setups for each measurement.
- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
ITER Toroidal Field Coil Delivery and Preparatory Work at the ITER Site
Most of the Toroidal Field coils have already been delivered to the ITER site and TF Coil preparatory work is ongoing in TF Coil Preparation Building before Sector Sub-Assembly. For the preparatory work, the ITER Organization established the installation process of Inner Leg Intercoil Structure (ILIS) panels, which are the key components to keep TF Coils insulated from each other and maintain the gap as 2 mm nominal between TF Coils, by welding washer-shaped parts to push the panels onto TF Coil Inner Leg. In addition, Local Machining Tools (LMT) were also developed to make dowel holes for Correction Coil (CC) Base Clamp installation and interface holes for Outboard Bracket to be attached during the transfer of Sector Module to Tokamak Pit. The LMT allows us to perform the various machining activities on the TF Coil without large machining center.
- 7 February 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-4
ITER Toroidal Field Coil Delivery and Preparatory Work at the ITER Site
Most of the Toroidal Field coils have already been delivered to the ITER site and TF Coil preparatory work is ongoing in TF Coil Preparation Building before Sector Sub-Assembly. For the preparatory work, the ITER Organization established the installation process of Inner Leg Intercoil Structure (ILIS) panels, which are the key components to keep TF Coils insulated from each other and maintain the gap as 2 mm nominal between TF Coils, by welding washer-shaped parts to push the panels onto TF Coil Inner Leg. In addition, Local Machining Tools (LMT) were also developed to make dowel holes for Correction Coil (CC) Base Clamp installation and interface holes for Outboard Bracket to be attached during the transfer of Sector Module to Tokamak Pit. The LMT allows us to perform the various machining activities on the TF Coil without large machining center.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-7
Completion of All Nine ITER Toroidal Field Coils in Japan
The fabrication of nine ITER toroidal field coils (TFCs) has been completed successfully in Japan. When a set of 18 TFCs are installed around the ITER vacuum vessel, it generates a plasma-confinement magnetic field. To achieve the required plasma-confinement quality, the error field should be limited to 50 ppm of the nominal toroidal field. This error field requirement is propagated to each component of the magnet system as manufacturing and assembly tolerances. For each TFC, this requirement is given in terms of current center line (CCL) tolerances. Even though the TFC is a gigantic module of 9 m wide and 16.5 m high, the positional tolerances allowed for its CCL is 2.6 mm in diameter at the straight portion and ±3.0 mm in lateral direction at the curved portion. On the other hand, limiting TFC assembly misalignments is also important in the minimization of the error field. Therefore, sub-millimeter profile tolerances are defined on the important interfaces of TFCs while the manufacturing of a TFC involved welding of 40 to 100 mm thick austenitic stainless steel. The completion of all nine TFCs is realized by the techniques developed through discussions and trials along the fabrication process. High accuracy, three-dimensional measurements with laser trackers were introduced to record the fabrication outcomes in each step and to feedback the data to the next step. Based on the measurement results accumulated in the process, the manufacturing results of all nine TFCs were evaluated in the view of its CCL quality and interface tolerances.
- 9 January 2024
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-7
Completion of All Nine ITER Toroidal Field Coils in Japan
The fabrication of nine ITER toroidal field coils (TFCs) has been completed successfully in Japan. When a set of 18 TFCs are installed around the ITER vacuum vessel, it generates a plasma-confinement magnetic field. To achieve the required plasma-confinement quality, the error field should be limited to 50 ppm of the nominal toroidal field. This error field requirement is propagated to each component of the magnet system as manufacturing and assembly tolerances. For each TFC, this requirement is given in terms of current center line (CCL) tolerances. Even though the TFC is a gigantic module of 9 m wide and 16.5 m high, the positional tolerances allowed for its CCL is 2.6 mm in diameter at the straight portion and ±3.0 mm in lateral direction at the curved portion. On the other hand, limiting TFC assembly misalignments is also important in the minimization of the error field. Therefore, sub-millimeter profile tolerances are defined on the important interfaces of TFCs while the manufacturing of a TFC involved welding of 40 to 100 mm thick austenitic stainless steel. The completion of all nine TFCs is realized by the techniques developed through discussions and trials along the fabrication process. High accuracy, three-dimensional measurements with laser trackers were introduced to record the fabrication outcomes in each step and to feedback the data to the next step. Based on the measurement results accumulated in the process, the manufacturing results of all nine TFCs were evaluated in the view of its CCL quality and interface tolerances.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 27 December 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 34 (5) , 1-5
Lessons Learned From EF1 Electrical Short Incident During JT-60SA Integrated Commissioning Test
The superconducting tokamak fusion test device, JT-60SA, was constructed as the Satellite Tokamak project in the Broader Approach Program between Japan and EU. During the JT-60SA integrated commissioning tests of the Nb-Ti equilibrium magnetic field coil EF1 high voltage (∼5 kV) test, the EF1 power supply current surged suddenly and was stopped by the overcurrent interlock of the power supply. At the same time, the vacuum in the cryostat deteriorated, and the pressure in the magnet cooling loops increased. After the system warmed up, visual inspection revealed that discharges occurred between ground and both positive and negative terminal joints of EF1. Several holes, melted by the electrical short and identified as the source of the helium leak into the cryostat, were found in the cylindrical metal part of the joint. The data recorded at the time of the event were analyzed with a conclusion that the discharge first occurred between the positive terminal joint and its support bracket at ground potential and immediately afterward between the neighboring negative terminal joint and its support bracket. These two arcs created a short-circuited loop through which the coil discharged for about 1.4 s. The energy during the short circuit is estimated to be about 60 kJ.
- 13 September 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 196
Procedure qualification and integration of the continuous external Rogowski diagnostics to the superconducting magnets of ITER tokamak
- 13 September 2023
- Published by Elsevier in Fusion Engineering and Design
- Vol. 196
Procedure qualification and integration of the continuous external Rogowski diagnostics to the superconducting magnets of ITER tokamak
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Influence of Axial Strain and Transverse Compressive Load on Critical Current of Nb3Sn Wires for the FCC
Nb 3 Sn superconducting wires are under consideration for producing high field accelerator magnets for the proposed Future Circular Collider (FCC) due to their high critical field. R&D studies are ongoing worldwide with a target non-Cu critical current density ( Jc ) of 1500 A/mm 2 at 4.2 K, 16 T. As an accomplishment of this R&D, one of the conductor manufacturers, JASTEC, has developed Nb 3 Sn wires with non-Cu Jc higher than 1100 A/mm 2 at 16 T, 4.2 K by a distributed-tin (DT) method. In high field Nb 3 Sn magnets, degradation of performance has been frequently reported due to the brittleness of Nb 3 Sn and the high electromagnetic force. To realize more robust Nb 3 Sn accelerator magnets, electro-mechanical properties of the conductors should be deeply understood. In this study, the variation of the critical current with mechanical loading is evaluated for a DT Nb 3 Sn wire in two configurations, i.e. under axial strain and under transverse compression.
- 6 February 2023
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 33 (5) , 1-5
Influence of Axial Strain and Transverse Compressive Load on Critical Current of Nb3Sn Wires for the FCC
Nb 3 Sn superconducting wires are under consideration for producing high field accelerator magnets for the proposed Future Circular Collider (FCC) due to their high critical field. R&D studies are ongoing worldwide with a target non-Cu critical current density ( Jc ) of 1500 A/mm 2 at 4.2 K, 16 T. As an accomplishment of this R&D, one of the conductor manufacturers, JASTEC, has developed Nb 3 Sn wires with non-Cu Jc higher than 1100 A/mm 2 at 16 T, 4.2 K by a distributed-tin (DT) method. In high field Nb 3 Sn magnets, degradation of performance has been frequently reported due to the brittleness of Nb 3 Sn and the high electromagnetic force. To realize more robust Nb 3 Sn accelerator magnets, electro-mechanical properties of the conductors should be deeply understood. In this study, the variation of the critical current with mechanical loading is evaluated for a DT Nb 3 Sn wire in two configurations, i.e. under axial strain and under transverse compression.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-6
Completion of the First ITER TF Coil in the Second Manufacturing Line in Japan
In Japan, 9 ITER TF coils for Japan and 10 TF coil cases (CCs) for EU are procured from two suppliers. In the second manufacturing line (ML), some of manufacturing procedures were optimized and/or rationalized from lessons learned from the experiences in the first ML. These efforts contributed to simplification and acceleration of the fabrication of the ITER TF coil in the second ML and then, the first ITER TF coil has been completed in May 2021 in the second ML. In addition, the most challenging processes in TF coil fabrication such as very accurate current center line positioning and proper gap between a winding pack (WP) and CC, more than 4 mm were achieved in assembly of WP and CC, as well as the first ML. These results justified the validity of the optimized and rationalized manufacturing procedure in the second ML. Therefore, we can say that manufacturing in both first and second MLs in Japan has become stable. Actually, four and two TF coils have been completed in the first and second MLs in Japan, respectively.
- 29 March 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-6
Completion of the First ITER TF Coil in the Second Manufacturing Line in Japan
In Japan, 9 ITER TF coils for Japan and 10 TF coil cases (CCs) for EU are procured from two suppliers. In the second manufacturing line (ML), some of manufacturing procedures were optimized and/or rationalized from lessons learned from the experiences in the first ML. These efforts contributed to simplification and acceleration of the fabrication of the ITER TF coil in the second ML and then, the first ITER TF coil has been completed in May 2021 in the second ML. In addition, the most challenging processes in TF coil fabrication such as very accurate current center line positioning and proper gap between a winding pack (WP) and CC, more than 4 mm were achieved in assembly of WP and CC, as well as the first ML. These results justified the validity of the optimized and rationalized manufacturing procedure in the second ML. Therefore, we can say that manufacturing in both first and second MLs in Japan has become stable. Actually, four and two TF coils have been completed in the first and second MLs in Japan, respectively.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Results of ITER TF Coil Double Pancake Heat Treatment in Japan
In Japan, 9 ITER TF coils were manufactured for the ITER project. Each TF coil consists of seven Nb3Sn conductor double pan-cakes (DPs). In DP manufacturing, heat treatment is one of the most important processes, because the insertion of a heat treated conductor into the radial plate groove (i.e., transfer) is complicated owing to the elongation of the conductor under heat treatment. A critical current distribution over the DP may also occur owing to the temperature distribution and disturbance in the heat treatment process. To address these issues, this study developed a procedure wherein the conductor length elongation caused by heat treatment is precisely considered, and transfer can be successfully achieved for all the DPs. In addition, strand witness samples were simultaneously heat treated with the DPs, and their critical cur-rent (Ic) was measured. Subsequently, it was confirmed that the average Ic is equivalent to those in the strand acceptance test while the standard deviation of Ic for the witness samples is ap-proximately 4 % larger than that for the strand acceptance test. It was also confirmed that the disturbance of the heat treatment was negligible. Related results are described herein.
- 1 February 2022
- Published by Institute of Electrical and Electronics Engineers (IEEE) in IEEE Transactions on Applied Superconductivity
- Vol. 32 (6) , 1-5
Results of ITER TF Coil Double Pancake Heat Treatment in Japan
In Japan, 9 ITER TF coils were manufactured for the ITER project. Each TF coil consists of seven Nb3Sn conductor double pan-cakes (DPs). In DP manufacturing, heat treatment is one of the most important processes, because the insertion of a heat treated conductor into the radial plate groove (i.e., transfer) is complicated owing to the elongation of the conductor under heat treatment. A critical current distribution over the DP may also occur owing to the temperature distribution and disturbance in the heat treatment process. To address these issues, this study developed a procedure wherein the conductor length elongation caused by heat treatment is precisely considered, and transfer can be successfully achieved for all the DPs. In addition, strand witness samples were simultaneously heat treated with the DPs, and their critical cur-rent (Ic) was measured. Subsequently, it was confirmed that the average Ic is equivalent to those in the strand acceptance test while the standard deviation of Ic for the witness samples is ap-proximately 4 % larger than that for the strand acceptance test. It was also confirmed that the disturbance of the heat treatment was negligible. Related results are described herein.
- Open Access
- 8 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (11) , 116044
Completion of the first ITER toroidal field coil in Japan
The first ITER toroidal field coil (TFC) has been successfully manufactured by the Japanese Domestic Agency in January 2020. The ITER TFCs are the largest Niobium Tin (Nb3Sn) superconducting magnets in the world; each is enclosed in an austenitic stainless-steel case with a height of 16.5 m and total weight is 310 tons (Knaster et al 2008 IEEE Trans. Appl. Supercond. 18 495–498). A set of 18 TFCs will be installed around vacuum vessel to function as a plasma confinement magnet system. The responsibility to procure 18 TFCs and 1 spare coil is shared between European Domestic Agency and Japanese Domestic Agency (Bellesia et al 2020 IEEE Trans. Appl. Supercond. 30 4202205; Sborchia et al 2008 IEEE Trans. Appl. Supercond. 18 463–466). To hold a common magnetic and geometrical properties among all the TFCs, tight tolerances of sub-millimeter order are defined on each TFC. The fabrication of those massive magnets with such tight tolerances involved some major technical challenges. These technical challenges were solved by pre-assessment and process qualification through some qualification trials. As a result, techniques established to solve those challenges were implemented to the TFC manufacturing, leading to the successful completion of the first TFC. The details are described in the paper.
- 8 October 2021
- Published by IOP Publishing in Nuclear Fusion
- Vol. 61 (11) , 116044
Open AccessCompletion of the first ITER toroidal field coil in Japan
The first ITER toroidal field coil (TFC) has been successfully manufactured by the Japanese Domestic Agency in January 2020. The ITER TFCs are the largest Niobium Tin (Nb3Sn) superconducting magnets in the world; each is enclosed in an austenitic stainless-steel case with a height of 16.5 m and total weight is 310 tons (Knaster et al 2008 IEEE Trans. Appl. Supercond. 18 495–498). A set of 18 TFCs will be installed around vacuum vessel to function as a plasma confinement magnet system. The responsibility to procure 18 TFCs and 1 spare coil is shared between European Domestic Agency and Japanese Domestic Agency (Bellesia et al 2020 IEEE Trans. Appl. Supercond. 30 4202205; Sborchia et al 2008 IEEE Trans. Appl. Supercond. 18 463–466). To hold a common magnetic and geometrical properties among all the TFCs, tight tolerances of sub-millimeter order are defined on each TFC. The fabrication of those massive magnets with such tight tolerances involved some major technical challenges. These technical challenges were solved by pre-assessment and process qualification through some qualification trials. As a result, techniques established to solve those challenges were implemented to the TFC manufacturing, leading to the successful completion of the first TFC. The details are described in the paper.