Jeff Kulhavy
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Jeff Kulhavy has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- Matthew D. Krasowski
Department of Pathology, University of Iowa Hospitals and Clinics , Iowa City, IA
4 shared publications - Scott R. Davis
Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
4 shared publications - Tami Bebber
Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
3 shared publications - Anna E. Merrill
Department of Pathology, University of Iowa Health Care , Iowa City, IA
2 shared publications - Dena R. Voss
Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
2 shared publications - Denise Jacob
Department of Pathology, University of Iowa Hospitals and Clinics, Iowa City, IA, USA
2 shared publications
Latest Publications
- Open Access
- 1 November 2020
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 22, e00176
Evaluation of switch from satellite laboratory to central laboratory for testing of intraoperative parathyroid hormone
- 1 November 2020
- Published by Elsevier in Practical Laboratory Medicine
- Vol. 22, e00176
Open AccessEvaluation of switch from satellite laboratory to central laboratory for testing of intraoperative parathyroid hormone
- Open Access
- 7 June 2015
- Published by Springer Nature in BMC Clinical Pathology
- Vol. 15 (1) , 11
Impact of add-on laboratory testing at an academic medical center: a five year retrospective study
Clinical laboratories frequently receive orders to perform additional tests on existing specimens (‘add-ons’). Previous studies have examined add-on ordering patterns over short periods of time. The objective of this study was to analyze add-on ordering patterns over an extended time period. We also analyzed the impact of a robotic specimen archival/retrieval system on add-on testing procedure and manual effort. In this retrospective study at an academic medical center, electronic health records from were searched to obtain all add-on orders that were placed in the time period of May 2, 2009 to December 31, 2014. During the time period of retrospective study, 880,359 add-on tests were ordered on 96,244 different patients. Add-on testing comprised 3.3 % of total test volumes. There were 443,411 unique ordering instances, leading to an average of 1.99 add-on tests per instance. Some patients had multiple episodes of add-on test orders at different points in time, leading to an average of 9.15 add-on tests per patient. The majority of add-on orders were for chemistry tests (78.8 % of total add-ons) with the next most frequent being hematology and coagulation tests (11.2 % of total add-ons). Inpatient orders accounted for 66.8 % of total add-on orders, while the emergency department and outpatient clinics had 14.8 % and 18.4 % of total add-on orders, respectively. The majority of add-ons were placed within 8 hours (87.3 %) and nearly all by 24 hours (96.8 %). Nearly 100 % of add-on orders within the emergency department were placed within 8 hours. The introduction of a robotic specimen archival/retrieval unit saved an average of 2.75 minutes of laboratory staff manual time per unique add-on order. This translates to 24.1 hours/day less manual effort in dealing with add-on orders. Our study reflects the previous literature in showing that add-on orders significantly impact the workload of the clinical laboratory. The majority of add-on orders are clinical chemistry tests, and most add-on orders occur within 24 hours of original specimen collection. Robotic specimen archival/retrieval units can reduce manual effort in the clinical laboratory associated with add-on orders.
- 7 June 2015
- Published by Springer Nature in BMC Clinical Pathology
- Vol. 15 (1) , 11
Open AccessImpact of add-on laboratory testing at an academic medical center: a five year retrospective study
Clinical laboratories frequently receive orders to perform additional tests on existing specimens (‘add-ons’). Previous studies have examined add-on ordering patterns over short periods of time. The objective of this study was to analyze add-on ordering patterns over an extended time period. We also analyzed the impact of a robotic specimen archival/retrieval system on add-on testing procedure and manual effort. In this retrospective study at an academic medical center, electronic health records from were searched to obtain all add-on orders that were placed in the time period of May 2, 2009 to December 31, 2014. During the time period of retrospective study, 880,359 add-on tests were ordered on 96,244 different patients. Add-on testing comprised 3.3 % of total test volumes. There were 443,411 unique ordering instances, leading to an average of 1.99 add-on tests per instance. Some patients had multiple episodes of add-on test orders at different points in time, leading to an average of 9.15 add-on tests per patient. The majority of add-on orders were for chemistry tests (78.8 % of total add-ons) with the next most frequent being hematology and coagulation tests (11.2 % of total add-ons). Inpatient orders accounted for 66.8 % of total add-on orders, while the emergency department and outpatient clinics had 14.8 % and 18.4 % of total add-on orders, respectively. The majority of add-ons were placed within 8 hours (87.3 %) and nearly all by 24 hours (96.8 %). Nearly 100 % of add-on orders within the emergency department were placed within 8 hours. The introduction of a robotic specimen archival/retrieval unit saved an average of 2.75 minutes of laboratory staff manual time per unique add-on order. This translates to 24.1 hours/day less manual effort in dealing with add-on orders. Our study reflects the previous literature in showing that add-on orders significantly impact the workload of the clinical laboratory. The majority of add-on orders are clinical chemistry tests, and most add-on orders occur within 24 hours of original specimen collection. Robotic specimen archival/retrieval units can reduce manual effort in the clinical laboratory associated with add-on orders.
- Open Access
- 24 September 2012
- Published by Springer Nature in BMC Clinical Pathology
- Vol. 12 (1) , 15
Positive hepatitis B surface antigen tests due to recent vaccination: a persistent problem
Background: Hepatitis B virus (HBV) is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg) are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods: The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone) results. Results: During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests) revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions: Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days post-vaccination. Our study also demonstrates that weakly positive HBsAg results often do not reflect actual HBV infection, underscoring the importance of confirmatory testing. This study also emphasizes that vaccination-induced HBsAg positives occur most commonly in hemodialysis patients.
- 24 September 2012
- Published by Springer Nature in BMC Clinical Pathology
- Vol. 12 (1) , 15
Open AccessPositive hepatitis B surface antigen tests due to recent vaccination: a persistent problem
Background: Hepatitis B virus (HBV) is a common cause of viral hepatitis with significant health complications including cirrhosis and hepatocellular carcinoma. Assays for hepatitis B surface antigen (HBsAg) are the most frequently used tests to detect HBV infection. Vaccination for HBV can produce transiently detectable levels of HBsAg in patients. However, the time course and duration of this effect is unclear. The objective of this retrospective study was to clarify the frequency and duration of transient HBsAg positivity following vaccination against HBV. Methods: The electronic medical record at an academic tertiary care medical center was searched to identify all orders for HBsAg within a 17 month time period. Detailed chart review was performed to identify all patients who were administered HBV vaccine within 180 days prior to HBsAg testing and also to ascertain likely cause of weakly positive (grayzone) results. Results: During the 17 month study period, 11,719 HBsAg tests were ordered on 9,930 patients. There were 34 tests performed on 34 patients who received HBV vaccine 14 days or less prior to HBsAg testing. Of these 34 patients, 11 had grayzone results for HBsAg that could be attributed to recent vaccination. Ten of the 11 patients were renal dialysis patients who were receiving HBsAg testing as part of routine and ongoing monitoring. Beyond 14 days, there were no reactive or grayzone HBsAg tests that could be attributed to recent HBV vaccination. HBsAg results reached a peak COI two to three days following vaccination before decaying. Further analysis of all the grayzone results within the 17 month study period (43 results out of 11,719 tests) revealed that only 4 of 43 were the result of true HBV infection as verified by confirmatory testing. Conclusions: Our study confirms that transient HBsAg positivity can occur in patients following HBV vaccination. The results suggest this positivity is unlikely to persist beyond 14 days post-vaccination. Our study also demonstrates that weakly positive HBsAg results often do not reflect actual HBV infection, underscoring the importance of confirmatory testing. This study also emphasizes that vaccination-induced HBsAg positives occur most commonly in hemodialysis patients.