LDLadislav Derzsi

Ladislav Derzsi

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ladislav Derzsi has a total of 66 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Emulsions in microfluidic channels with asymmetric boundary conditions and directional surface roughness: stress and rheology

    by Francesca Pelusi, Daniele Filippi, Ladislav Derzsi, Matteo Pierno, Mauro Sbragaglia

    The flow of emulsions in confined microfluidic channels is affected by surface roughness. Directional roughness effects have recently been reported in channels with asymmetric boundary conditions featuring a flat wall, and a wall textured with a directional roughness, the latter promoting a change in the velocity profiles when the flow direction of emulsions is inverted [D. Filippi et al., Adv. Mater. Technol.8, 2201748 (2023)]. An operative protocol is needed to reconstruct the stress profile inside the channel from velocity data to shed light on the trigger of the directional response. To this aim, we performed lattice Boltzmann numerical simulations of the flow of model emulsions with a minimalist model of directional roughness in two dimensions: a confined microfluidic channel with one flat wall and the other patterned by right-angle triangular-shaped posts. Simulations are essential to develop the protocol based on mechanical arguments to reconstruct stress profiles. Hence, one can analyze data to relate directional effects in velocity profiles to different rheological responses close to the rough walls associated with opposite flow directions. We finally show the universality of this protocol by applying it to other realizations of directional roughness by considering experimental data on emulsions in a microfluidic channel featured with a flat wall and a wall textured by herringbone-shaped roughness.


  • Open Access

    Opto-hydrodynamic tweezers

    by Shreyas Vasantham, Abhay Kotnala, Yurii Promovych, Piotr Garstecki, Ladislav Derzsi

    The manuscript unveils a portable optofluidic device for precise trapping, manipulation, and sorting of single cells/particles using a single standard unmodified optical fiber in a microfluidic channel—a notable advance in optofluidic technology.


  • Open Access

    Opto-hydrodynamic fiber tweezers for stimulated raman imaging cytometry of leukemic cells

    by Shreyas Vasantham, Piotr Garstecki, Ladislav Derzsi, Abhay Kotnala

    SPIE Digital Library Proceedings

  • Open Access

    Boost and Contraction of Flow by Herringbone Surface Design on the Microfluidic Channel Wall

    by Daniele Filippi, Ladislav Derzsi, Francesco Nalin, Andrea Vezzani, Davide Ferraro, Annamaria Zaltron, Giampaolo Mistura, Matteo Pierno

    The handling of yield‐stress fluids typically involves a jammed‐to‐flow transition that is pivotal for many injection and transport technologies on different scales, such as additive manufacturing, injection molding, food rheology, and oil transport. For all of these applications, it is crucial to be able to tune the fluidization under constant load. The pressure‐driven flow of emulsions is reported within a microfluidic channel, one wall of which is patterned by a herringbone‐riblet roughness comprising a regular array of V‐shaped grooves. With respect to the pressure gradient, this pattern displays a convergent (divergent) orientation that provides a forward (backward) direction. At the tip of the herringbone pattern, the forward and backward flows are almost identical for a viscous Newtonian fluid and a diluted emulsion, whereas a surprising flow boost in the forward direction is observed as the emulsion approaches a jammed state. The flow boost is more effective at small herringbone angles and low pressure loads. 3D velocity profiles along the channel cross‐section unravel unexpected heterogeneous stress, band‐like distributed, with evidence of nonlocal correlations.


  • Open Access

    In-Capillary Photodeposition of Glyphosate-Containing Polyacrylamide Nanometer-Thick Films

    by Jaroslaw Mazuryk, Katarzyna Klepacka, Joanna Piechowska, Jakub Kalecki, Ladislav Derzsi, Piotr Piotrowski, Piotr Paszke, Dorota A. Pawlak, Simone Berneschi, Wlodzimierz Kutner, et al.

    The present research reports on in-water, site-specific photodeposition of glyphosate (GLP)-containing polyacrylamide (PAA-GLP) nanometer-thick films (nanofilms) on an inner surface of fused silica (fused quartz) microcapillaries presilanized with trimethoxy(octen-7-yl)silane (TMOS). TMOS was chosen because of the vinyl group presence in its structure, enabling its participation in the (UV light)-activated free-radical polymerization (UV-FRP) after its immobilization on a fused silica surface. The photodeposition was conducted in an aqueous (H2O/ACN; 3:1, v/v) solution, using UV-FRP (λ = 365 nm) of the acrylamide (AA) functional monomer, the N,N'-methylenebis(acrylamide) (BAA) cross-linking monomer, GLP, and the azobisisobutyronitrile (AIBN) UV-FRP initiator. Acetonitrile (ACN) was used as the porogen and the solvent to dissolve monomers and GLP. Because of the micrometric diameters of microcapillaries, the silanization and photodeposition procedures were first optimized on fused silica slides. The introduction of TMOS, as well as the formation of PAA and PAA-GLP nanofilms, was determined using atomic force microscopy (AFM), scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) spectroscopy, and confocal micro-Raman spectroscopy. Particularly, AFM and SEM-EDX measurements determined nanofilms' thickness and GLP content, respectively, whereas in-depth confocal (micro-Raman spectroscopy)-assisted imaging of PAA- and PAA-GLP-coated microcapillary inner surfaces confirmed the successful photodeposition. Moreover, we examined the GLP impact on polymer gelation by monitoring hydration in a hydrogel and a dried powder PAA-GLP. Our study demonstrated the usefulness of the in-capillary micro-Raman spectroscopy imaging and in-depth profiling of GLP-encapsulated PAA nanofilms. In the future, our simple and inexpensive procedure will enable the fabrication of polymer-based microfluidic chemosensors or adsorptive-separating devices for GLP detection, determination, and degradation.


  • Open Access

    A double-step emulsification device for direct generation of double emulsions

    by Yu-Kai Lai, Adam S. Opalski, Piotr Garstecki, Ladislav Derzsi, Jan Guzowski

    In microfluidic step emulsification, the size of droplets generated in the dripping regime is predominantly determined by the nozzle's height and only weakly depends on the applied flow rates or liquid properties. While the generation of monodisperse emulsions at high throughput using step emulsifiers has been well established, the generation of double emulsions, i.e., liquid core–shell structures, is still challenging. Here, we demonstrate a novel double-step emulsification method for the direct generation of multi-core double-emulsions and provide a predictive model for the number of cores. While the mechanism of the formation of the core droplets or empty shell droplets follows the well-established scenario of simple step emulsification, the formation of double-emulsion droplets is strongly affected by the presence of the cores. Passing of the cores through the narrowing neck of the shell postpones shell pinch-off. In particular, we demonstrate that our system can be used for the generation of arbitrary large, tightly packed droplet clusters consisting of a controllable number of droplets. Finally, we discuss the options of upscaling the system for high-throughput generation of tailored double emulsions.


  • Open Access

    Split or slip – passive generation of monodisperse double emulsions with cores of varying viscosity in microfluidic tandem step emulsification system

    by Adam S. Opalski, Karol Makuch, Ladislav Derzsi, Piotr Garstecki

    We investigate the role of fluid viscosities on formation of double emulsion in a microfluidic step emulsification system. The ratio of fluid viscosities controls double droplet formation, leading to splitting of the core for low core-to-shell viscosity ratio.


  • Open Access

    Combinatorial Antimicrobial Susceptibility Testing Enabled by Non-Contact Printing

    by Adam S. Opalski, Artur Ruszczak, Yurii Promovych, Michał Horka, Ladislav Derzsi, Piotr Garstecki

    We demonstrate the utility of non-contact printing to fabricate the mAST—an easy-to-operate, microwell-based microfluidic device for combinatorial antibiotic susceptibility testing (AST) in a point-of-care format. The wells are prefilled with antibiotics in any desired concentration and combination by non-contact printing (spotting). For the execution of the AST, the only requirements are the mAST device, the sample, and the incubation chamber. Bacteria proliferation can be continuously monitored by using an absorbance reader. We investigate the profile of resistance of two reference Escherichia coli strains, report the minimum inhibitory concentration (MIC) for single antibiotics, and assess drug–drug interactions in cocktails by using the Bliss independence model.


  • Direct droplet digital PCR (dddPCR) for species specific, accurate and precise quantification of bacteria in mixed samples

    by Natalia Pacocha, Ott Scheler, Mikolaj Marcin Nowak, Ladislav Derzsi, Joanna Cichy, Piotr Garstecki

    Here we demonstrate a direct droplet digital PCR assay (dddPCR) for simultaneous identification and quantification of bacteria in a bacterial mixture.


  • Open Access

    Grooved step emulsification systems optimize the throughput of passive generation of monodisperse emulsions

    by Adam S. Opalski, Karol Makuch, Yu-Kai Lai, Ladislav Derzsi, Piotr Garstecki

    Microfluidic step emulsification passively produces highly monodisperse droplets and can be easily parallelized for high throughput emulsion production. The two main techniques used for step emulsification are: i) edge-based droplet generation (EDGE), where droplets are formed in a single, very wide and shallow nozzle, and ii) microchannel emulsification (MCE), where droplets are formed in many separated narrow nozzles. These techniques differ in modes of droplet formation that influence the throughput and monodispersity of produced emulsions. Here we report a systematic study of novel grooved step emulsifying geometries, a hybrid of MCE and EDGE architectures. We introduce partitions of different heights to a wide (EDGE-like) slit to establish optimal geometries for high-throughput droplet production. We demonstrate that the volume and monodispersity of the produced emulsion can be tuned solely by changing the height of these partitions. We show that the spacing of the partitions influences the size of the produced droplets, but not the population monodispersity. We also determine the moment of transition between two distinct droplet generation modes as a function of the geometrical parameters of the nozzle. The optimized grooved geometry appears to combine the advantages of both MCE and EDGE, i.e. spatial localization of droplet forming units (DFUs), high-throughput formation of tightly monodisperse droplets from parallel DFUs, and low sensitivity to variation in the flow rate of the dispersed phase. As a proof-of-concept we show grooved devices that for a 260-fold increase of flow rate produce droplets with volume increased by just 75%, as compared to 91% increase in volume over a 180-fold increase of flow rate of the dispersed phase in MCE devices. We also present the optimum microfluidic device geometry that almost doubles the throughput of an MCE device in the generation of nanoliter droplets.