Ihssan S. Masad
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Ihssan S. Masad has a total of 40 co-authors. Here are the top co-authors by number of shared publications:
- Isam Abu-Qasmieh
Department of Biomedical Systems and Informatics Engineering, Yarmouk University, Irbid, Jordan
2 shared publications - Khaled Zayed Alawneh
Department of Radiology and Nuclear Medicine, Jordan University of Science and Technology, P.O. Box 3030, Irbid 22110, Jordan
2 shared publications Abdallah J. Nofal
Affiliation Diagnostic Radiology Department, King Hussein Cancer Center, Amman, Jordan
1 shared publication- Abdullah Al Kafi
Affiliation Biomedical Physics Department, Research Center, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia
1 shared publication Abeer Obeid
Hashemite University
1 shared publicationAhmed M. Masawi
Affiliation Biomedical Physics Department, Research Center, King Faisal Specialist Hospital and Research Center, Riyadh, Saudi Arabia
1 shared publication
Latest Publications
- Open Access
NeuroFusion-Rehab: Cloud-Integrated IoT System for Privacy-Preserving Telerehabilitation Using Remote Monitoring
Smart telerehabilitation requires accurate motion assessment while protecting patient privacy and supporting real-time interaction between patients and clinicians. RGB-based approaches can expose identifying appearance information, whereas conventional depth-based methods may insufficiently represent long-range temporal dependencies and heterogeneous motion features. This study presents NeuroFusion-Rehab, an IoT-enabled depth-centric framework for privacy-preserving telerehabilitation and cloud-assisted monitoring. Depth silhouettes are processed using geometry-constrained CoTracker for dense motion tracking, depth-adapted DISK for shape-aware keypoints, DINOv2 for structural self-attention features, and 3D point clouds for geometric representation. A Hybrid Adaptive Spectro-Frequency Encoding (HASFE) module combines wavelet scattering and empirical mode decomposition to characterize multi-scale motion dynamics. The heterogeneous features are fused, optimized using Grey Wolf Optimization, and classified with a Graph Neural Network to model spatiotemporal relationships. An edge–cloud IoT architecture supports structured acquisition, transmission, visualization, and clinician-assisted monitoring. The framework achieved classification accuracy of 94.1% on KiMoRe, 95.9% on UT-Kinect, and 95.1% on NTU RGB-D 120. These results indicate that integrating depth-based geometric, structural, temporal, and spectral representations can provide accurate appearance-agnostic motion analysis for scalable remote rehabilitation and is compatible with emerging 6G-oriented intelligent healthcare architectures.
Open AccessNeuroFusion-Rehab: Cloud-Integrated IoT System for Privacy-Preserving Telerehabilitation Using Remote Monitoring
Smart telerehabilitation requires accurate motion assessment while protecting patient privacy and supporting real-time interaction between patients and clinicians. RGB-based approaches can expose identifying appearance information, whereas conventional depth-based methods may insufficiently represent long-range temporal dependencies and heterogeneous motion features. This study presents NeuroFusion-Rehab, an IoT-enabled depth-centric framework for privacy-preserving telerehabilitation and cloud-assisted monitoring. Depth silhouettes are processed using geometry-constrained CoTracker for dense motion tracking, depth-adapted DISK for shape-aware keypoints, DINOv2 for structural self-attention features, and 3D point clouds for geometric representation. A Hybrid Adaptive Spectro-Frequency Encoding (HASFE) module combines wavelet scattering and empirical mode decomposition to characterize multi-scale motion dynamics. The heterogeneous features are fused, optimized using Grey Wolf Optimization, and classified with a Graph Neural Network to model spatiotemporal relationships. An edge–cloud IoT architecture supports structured acquisition, transmission, visualization, and clinician-assisted monitoring. The framework achieved classification accuracy of 94.1% on KiMoRe, 95.9% on UT-Kinect, and 95.1% on NTU RGB-D 120. These results indicate that integrating depth-based geometric, structural, temporal, and spectral representations can provide accurate appearance-agnostic motion analysis for scalable remote rehabilitation and is compatible with emerging 6G-oriented intelligent healthcare architectures.
- Open Access
- 24 September 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1807342
A simulation study of differentially private federated learning with zero-trust policy screening for medical IoT devices
Artificial intelligence is increasingly used in connected medical-device systems for physiological-signal classification and continuous monitoring. This paper presents a simulation study of the learning and policy layers of a zero-trust federated-learning framework for Internet of Medical Things (IoMT) devices. The implemented prototype combines federated averaging, Gaussian perturbation of client updates, a device-level trust score, and gradient-magnitude screening of anomalous client updates. This is a simulation study of the federated-learning and zero-trust policy layers; cryptographic, encrypted-transport, and hardware-attestation components are modeled as deployment considerations or overheads and are not implemented as complete physical or protocol-level modules. Using the ECG classification pipeline described in the methodology, we compare centralized training, traditional federated learning, differentially private federated learning, and the proposed zero-trust federated configuration. The proposed ZT-FL configuration is reported at 0.928 accuracy, 0.920 F1-score, and 0.968 AUC. These results support feasibility within the stated simulation scope and do not establish clinical validity, formal end-to-end DP accounting, comprehensive adversarial robustness, regulatory compliance, or post-quantum readiness.
- 24 September 2026
- Published by Frontiers Media SA in Frontiers in Digital Health
- Vol. 8, 1807342
Open AccessA simulation study of differentially private federated learning with zero-trust policy screening for medical IoT devices
Artificial intelligence is increasingly used in connected medical-device systems for physiological-signal classification and continuous monitoring. This paper presents a simulation study of the learning and policy layers of a zero-trust federated-learning framework for Internet of Medical Things (IoMT) devices. The implemented prototype combines federated averaging, Gaussian perturbation of client updates, a device-level trust score, and gradient-magnitude screening of anomalous client updates. This is a simulation study of the federated-learning and zero-trust policy layers; cryptographic, encrypted-transport, and hardware-attestation components are modeled as deployment considerations or overheads and are not implemented as complete physical or protocol-level modules. Using the ECG classification pipeline described in the methodology, we compare centralized training, traditional federated learning, differentially private federated learning, and the proposed zero-trust federated configuration. The proposed ZT-FL configuration is reported at 0.928 accuracy, 0.920 F1-score, and 0.968 AUC. These results support feasibility within the stated simulation scope and do not establish clinical validity, formal end-to-end DP accounting, comprehensive adversarial robustness, regulatory compliance, or post-quantum readiness.
- Open Access
- 14 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0349404
Evaluation of an acrylic acid hydrogel dosimeter for 3-D dose verification in radiotherapy using MRI
Gel dosimeters are commonly used to verify the dose distribution and consequently, ensure the accurate delivery of the dose as planned, which is very critical for the success of the radiotherapy. The current study aims to investigate the feasibility of using the magnetic resonance imaging (MRI)-based relaxation rate maps (R2 maps) of the novel acrylic acid with organic glucose polyvinyl alcohol (ACAGLPVA) hydrogel dosimeter for 3-D dose verification. The (ACAGLPVA) hydrogel was prepared and scanned with a 3-T MRI, prior to irradiation, using a spin-echo (SE) sequence. A series of 30 images with different echo times (TE) were acquired in order to generate R2 maps. The hydrogel was then irradiated with a maximum dose of 8 Gy using a CyberKnife system and the same MRI scans were acquired again for the irradiated gel phantom. The measured dose distributions obtained from R2-MRI maps were compared, using 2-D and 3-D Gamma analyses with 3% dose difference and 3-mm distance-to-agreement criteria, to those calculated from the treatment planning system (TPS). Results have shown high spatial agreement between the dose distributions calculated from TPS and the dose distributions derived from R2 maps, particularly in high-dose regions. The 3-D Gamma analysis achieved pass rates exceeding 90% across all planes for all evaluated dose levels—namely 90%, 70%, 50% and 20% of the maximum dose in the axial plane, as well as 90%, 70% and 50% of the maximum dose in the coronal and sagittal planes. In conclusion, based on the analysis of R2-MRI maps, this study has demonstrated the reliability of using the novel (ACAGLPVA) hydrogel dosimeter as an accurate tool for 3-D verification of radiotherapy treatment plans.
- 14 May 2026
- Published by Public Library of Science (PLoS) in PLOS ONE
- Vol. 21 (5) , e0349404
Open AccessEvaluation of an acrylic acid hydrogel dosimeter for 3-D dose verification in radiotherapy using MRI
Gel dosimeters are commonly used to verify the dose distribution and consequently, ensure the accurate delivery of the dose as planned, which is very critical for the success of the radiotherapy. The current study aims to investigate the feasibility of using the magnetic resonance imaging (MRI)-based relaxation rate maps (R2 maps) of the novel acrylic acid with organic glucose polyvinyl alcohol (ACAGLPVA) hydrogel dosimeter for 3-D dose verification. The (ACAGLPVA) hydrogel was prepared and scanned with a 3-T MRI, prior to irradiation, using a spin-echo (SE) sequence. A series of 30 images with different echo times (TE) were acquired in order to generate R2 maps. The hydrogel was then irradiated with a maximum dose of 8 Gy using a CyberKnife system and the same MRI scans were acquired again for the irradiated gel phantom. The measured dose distributions obtained from R2-MRI maps were compared, using 2-D and 3-D Gamma analyses with 3% dose difference and 3-mm distance-to-agreement criteria, to those calculated from the treatment planning system (TPS). Results have shown high spatial agreement between the dose distributions calculated from TPS and the dose distributions derived from R2 maps, particularly in high-dose regions. The 3-D Gamma analysis achieved pass rates exceeding 90% across all planes for all evaluated dose levels—namely 90%, 70%, 50% and 20% of the maximum dose in the axial plane, as well as 90%, 70% and 50% of the maximum dose in the coronal and sagittal planes. In conclusion, based on the analysis of R2-MRI maps, this study has demonstrated the reliability of using the novel (ACAGLPVA) hydrogel dosimeter as an accurate tool for 3-D verification of radiotherapy treatment plans.
- Open Access
- 11 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2304
GlioSurvQNet: A DuelContextAttn DQN Framework for Brain Tumor Prognosis with Metaheuristic Optimization
Background/Objectives: Accurate classification of brain tumors and reliable prediction of patient survival are essential in neuro-oncology, guiding clinical decisions and enabling precision treatment planning. However, conventional machine learning and deep learning methods often struggle with challenges such as data scarcity, class imbalance, limited model interpretability, and poor generalization across diverse clinical settings. This study presents GlioSurvQNet, a novel reinforcement learning-based framework designed to address these limitations for both glioma grading and survival prediction. Methods: GlioSurvQNet is built upon a DuelContextAttn Deep Q-Network (DQN) architecture, tailored for binary classification of low-grade vs. high-grade gliomas and multi-class survival prediction (short-, medium-, and long-term categories). Radiomics features were extracted from multimodal MRI scans, including FLAIR, T1CE, and T2 sequences. Feature optimization was performed using a hybrid ensemble of metaheuristic algorithms, including Harris Hawks Optimization (HHO), Modified Gorilla Troops Optimization (mGTO), and Zebra Optimization Algorithm (ZOA). Subsequently, SHAP-based feature selection was applied to enhance model interpretability and robustness. Results: The classification module achieved the highest accuracy of 99.27% using the FLAIR + T1CE modality pair, while the survival prediction model attained an accuracy of 93.82% with the FLAIR + T2 + T1CE fusion. Comparative evaluations against established machine learning and deep learning models demonstrated that GlioSurvQNet consistently outperformed existing approaches in both tasks. Conclusions: GlioSurvQNet offers a powerful and interpretable AI-driven solution for brain tumor analysis. Its high accuracy and robustness make it a promising tool for clinical decision support in glioma diagnosis and prognosis.
- 11 September 2025
- Published by MDPI AG in Diagnostics
- Vol. 15 (18) , 2304
Open AccessGlioSurvQNet: A DuelContextAttn DQN Framework for Brain Tumor Prognosis with Metaheuristic Optimization
Background/Objectives: Accurate classification of brain tumors and reliable prediction of patient survival are essential in neuro-oncology, guiding clinical decisions and enabling precision treatment planning. However, conventional machine learning and deep learning methods often struggle with challenges such as data scarcity, class imbalance, limited model interpretability, and poor generalization across diverse clinical settings. This study presents GlioSurvQNet, a novel reinforcement learning-based framework designed to address these limitations for both glioma grading and survival prediction. Methods: GlioSurvQNet is built upon a DuelContextAttn Deep Q-Network (DQN) architecture, tailored for binary classification of low-grade vs. high-grade gliomas and multi-class survival prediction (short-, medium-, and long-term categories). Radiomics features were extracted from multimodal MRI scans, including FLAIR, T1CE, and T2 sequences. Feature optimization was performed using a hybrid ensemble of metaheuristic algorithms, including Harris Hawks Optimization (HHO), Modified Gorilla Troops Optimization (mGTO), and Zebra Optimization Algorithm (ZOA). Subsequently, SHAP-based feature selection was applied to enhance model interpretability and robustness. Results: The classification module achieved the highest accuracy of 99.27% using the FLAIR + T1CE modality pair, while the survival prediction model attained an accuracy of 93.82% with the FLAIR + T2 + T1CE fusion. Comparative evaluations against established machine learning and deep learning models demonstrated that GlioSurvQNet consistently outperformed existing approaches in both tasks. Conclusions: GlioSurvQNet offers a powerful and interpretable AI-driven solution for brain tumor analysis. Its high accuracy and robustness make it a promising tool for clinical decision support in glioma diagnosis and prognosis.
- 10 April 2024
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 64, 95-104
Volumetric Alterations in Brain Structures Caused by Autism during Different Age Stages
Conclusions in literature regarding the effect of Autism on the size of different brain structures are contradictory. The aim of this study is to determine the effect of Autism on the volumes of different brain subcortical structures, and the age stage at which those changes occur. 7 main brain structures were segmented and their volumes were obtained. Volumes and the ratio of the volume to total brain volume (SBR) were compared in Autism group to their corresponding values in Control group. Then, each group was divided into 4 subgroups based on age; the comparison was repeated for each subgroup. Independent t-test was used to determine if significant differences existed between compared groups. Significant reductions were observed in the SBR of Autistic Pallidum and Accumbens compared to Control group when considering the full range of ages (5–25 years). However, Amygdala’s volume was significantly smaller in Autism in the 5–8 year subgroup. In addition, the SBR of Putaman, Pallidum, Hippocampus, and Accumbens were reduced in the 18–25 year Autism subgroup. In conclusion, the alteration in the ratio of structure’s volume to total brain volume is a better indicator of Autism diagnosis than change in the absolute volume alone.
- 10 April 2024
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 64, 95-104
Volumetric Alterations in Brain Structures Caused by Autism during Different Age Stages
Conclusions in literature regarding the effect of Autism on the size of different brain structures are contradictory. The aim of this study is to determine the effect of Autism on the volumes of different brain subcortical structures, and the age stage at which those changes occur. 7 main brain structures were segmented and their volumes were obtained. Volumes and the ratio of the volume to total brain volume (SBR) were compared in Autism group to their corresponding values in Control group. Then, each group was divided into 4 subgroups based on age; the comparison was repeated for each subgroup. Independent t-test was used to determine if significant differences existed between compared groups. Significant reductions were observed in the SBR of Autistic Pallidum and Accumbens compared to Control group when considering the full range of ages (5–25 years). However, Amygdala’s volume was significantly smaller in Autism in the 5–8 year subgroup. In addition, the SBR of Putaman, Pallidum, Hippocampus, and Accumbens were reduced in the 18–25 year Autism subgroup. In conclusion, the alteration in the ratio of structure’s volume to total brain volume is a better indicator of Autism diagnosis than change in the absolute volume alone.
- 12 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 169, 107842
CT-based generation of synthetic-pseudo MR images with different weightings for human knee
- 12 December 2023
- Published by Elsevier in Computers in Biology and Medicine
- Vol. 169, 107842
CT-based generation of synthetic-pseudo MR images with different weightings for human knee
- Open Access
- 3 May 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1244-1259
Generation of Synthetic-Pseudo MR Images from Real CT Images
This study aimed to generate synthetic MR images from real CT images. CT# mean and standard deviation of a moving window across every pixel in the reconstructed CT images were mapped to their corresponding tissue-mimicking types. Identification of the tissue enabled remapping it to its corresponding intrinsic parameters: T1, T2, and proton density (ρ). Lastly, synthetic weighted MR images of a selected slice were generated by simulating a spin-echo sequence using the intrinsic parameters and proper contrast parameters (TE and TR). Experiments were performed on a 3D multimodality abdominal phantom and on human knees at different TE and TR parameters to confirm the clinical effectiveness of the approach. Results demonstrated the validity of the approach of generating synthetic MR images at different weightings using only CT images and the three predefined mapping functions. The slope of the fitting line and percentage root-mean-square difference (PRD) between real and synthetic image vector representations were (0.73, 10%), (0.9, 18%), and (0.2, 8.7%) for T1-, T2-, and ρ-weighted images of the phantom, respectively. The slope and PRD for human knee images, on average, were 0.89% and 18.8%, respectively. The generated MR images provide valuable guidance for physicians with regard to deciding whether acquiring real MR images is crucial.
- 3 May 2022
- Published by MDPI AG in Tomography
- Vol. 8 (3) , 1244-1259
Open AccessGeneration of Synthetic-Pseudo MR Images from Real CT Images
This study aimed to generate synthetic MR images from real CT images. CT# mean and standard deviation of a moving window across every pixel in the reconstructed CT images were mapped to their corresponding tissue-mimicking types. Identification of the tissue enabled remapping it to its corresponding intrinsic parameters: T1, T2, and proton density (ρ). Lastly, synthetic weighted MR images of a selected slice were generated by simulating a spin-echo sequence using the intrinsic parameters and proper contrast parameters (TE and TR). Experiments were performed on a 3D multimodality abdominal phantom and on human knees at different TE and TR parameters to confirm the clinical effectiveness of the approach. Results demonstrated the validity of the approach of generating synthetic MR images at different weightings using only CT images and the three predefined mapping functions. The slope of the fitting line and percentage root-mean-square difference (PRD) between real and synthetic image vector representations were (0.73, 10%), (0.9, 18%), and (0.2, 8.7%) for T1-, T2-, and ρ-weighted images of the phantom, respectively. The slope and PRD for human knee images, on average, were 0.89% and 18.8%, respectively. The generated MR images provide valuable guidance for physicians with regard to deciding whether acquiring real MR images is crucial.
- 1 April 2019
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 41, 11-22
Spinal Curvature and Lower Extremities Kinematics of Simulated Pregnancy during Stair Ascending and Descending
The purpose of this work is to investigate the effect of anteriorly-added mass to simulate pregnancy on lower extremities kinematic and lumbar and thoracic angles during stair ascending and descending. 18 healthy females ascended and descended, with and without a pseudo-pregnancy sac of 12 kg (experimental and control groups, respectively), a costume-made wooden staircase while instrumented with 20 reflective markers placed on the lower extremities and the spine. The movements were captured by 12 infrared cameras surrounding the staircase. Tracked position data were exported to MATLAB to calculate the required joints angles. SPSS was used to compare the ascent and descent phases of control group, and to find if there are any significant differences between control and experimental groups in the ascent phase as well as in the descent phase. When comparing the ascent and descent phases of control group, data revealed a higher hip flexion during ascending and greater ankle planter-flexion and dorsiflexion, lumbar, and thoracic angles during descending; however, no significant difference was shown in the knee flexion angle between ascending and descending. Non-pregnant data showed greater maximum hip flexion and ankle dorsiflexion during stair ascending compared to simulated-pregnant group; while ankle planter-flexion, knee flexion, and lumbar angle were greater for simulated-pregnant status. During stair descending, non-pregnant group had greater minimum hip flexion and ankle dorsiflexion compared to simulated pregnant group; while ankle planter-flexion, knee flexion, and maximum hip flexion were greater for simulated-pregnant group. However, the lumbar and thoracic angles were found to be similar for simulated-pregnant and non-pregnant groups during stair descending. In conclusion, the current study revealed important kinematic modifications pregnant women adopt while ascending and descending stairs at their final stage of pregnancy to increase their stability.
- 1 April 2019
- Published by Trans Tech Publications, Ltd. in Journal of Biomimetics, Biomaterials and Biomedical Engineering
- Vol. 41, 11-22
Spinal Curvature and Lower Extremities Kinematics of Simulated Pregnancy during Stair Ascending and Descending
The purpose of this work is to investigate the effect of anteriorly-added mass to simulate pregnancy on lower extremities kinematic and lumbar and thoracic angles during stair ascending and descending. 18 healthy females ascended and descended, with and without a pseudo-pregnancy sac of 12 kg (experimental and control groups, respectively), a costume-made wooden staircase while instrumented with 20 reflective markers placed on the lower extremities and the spine. The movements were captured by 12 infrared cameras surrounding the staircase. Tracked position data were exported to MATLAB to calculate the required joints angles. SPSS was used to compare the ascent and descent phases of control group, and to find if there are any significant differences between control and experimental groups in the ascent phase as well as in the descent phase. When comparing the ascent and descent phases of control group, data revealed a higher hip flexion during ascending and greater ankle planter-flexion and dorsiflexion, lumbar, and thoracic angles during descending; however, no significant difference was shown in the knee flexion angle between ascending and descending. Non-pregnant data showed greater maximum hip flexion and ankle dorsiflexion during stair ascending compared to simulated-pregnant group; while ankle planter-flexion, knee flexion, and lumbar angle were greater for simulated-pregnant status. During stair descending, non-pregnant group had greater minimum hip flexion and ankle dorsiflexion compared to simulated pregnant group; while ankle planter-flexion, knee flexion, and maximum hip flexion were greater for simulated-pregnant group. However, the lumbar and thoracic angles were found to be similar for simulated-pregnant and non-pregnant groups during stair descending. In conclusion, the current study revealed important kinematic modifications pregnant women adopt while ascending and descending stairs at their final stage of pregnancy to increase their stability.
- Open Access
- 1 April 2011
- Published by Wiley in The FASEB Journal
- Vol. 25 (S1) , 1051.38
MR‐determined Sarcopenia and Associated Transcript Factors in Sprague‐Dawley Male Rats
- 1 April 2011
- Published by Wiley in The FASEB Journal
- Vol. 25 (S1) , 1051.38
Open AccessMR‐determined Sarcopenia and Associated Transcript Factors in Sprague‐Dawley Male Rats