Kim L. Ward
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Kim L. Ward has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
Alan James
Western Australian Sleep Disorders Research Institute, Queen Elizabeth Medical Centre, Perth, Australia
2 shared publications- Alexandra P. Bremner
School of Population Health, The University of Western Australia, Crawley, Western Australia, Australia
2 shared publications Annette C. Fedson
Center for Sleep and Circadian Neurobiology, University of Pennsylvania, PA
2 shared publications- David R. Hillman
West Australian Sleep Disorders Research Institute, Centre for Sleep Science, University of Western Australia, Perth, Australia
2 shared publications - Laila Simpson
Centre for Genetic Epidemiology and Biostatistics, University of Western Australia, Perth, Australia
2 shared publications - Lyle John Palmer
School of Public Health, College of Health, Adelaide University, Adelaide, Australia
2 shared publications
Latest Publications
- 15 April 2015
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 11 (4) , 433-444
A Comprehensive Evaluation of a Two-Channel Portable Monitor to “Rule in” Obstructive Sleep Apnea
We hypothesized that a dual-channel portable monitor (PM) device could accurately identify patients who have a high pretest probability of obstructive sleep apnea (OSA), and we evaluated factors that may contribute to variability between PM and polysomnography (PSG) results. Consecutive clinic patients (N = 104) with possible OSA completed a home PM study, a PM study simultaneous with laboratory PSG, and a second home PM study. Uniform data analysis methods were applied to both PM and PSG data. Primary outcomes of interest were the positive likelihood ratio (LR+) and sensitivity of the PM device to "rule-in" OSA, defined as an apnea-hypopnea index (AHI) ≥ 5 events/h on PSG. Effects of different test environment and study nights, and order of study and analysis methods (manual compared to automated) on PM diagnostic accuracy were assessed. The PM has adequate LR+ (4.8), sensitivity (80%), and specificity (83%) for detecting OSA in the unattended home setting when benchmarked against laboratory PSG, with better LR+ (> 5) and specificity (100%) and unchanged sensitivity (80%) in the simultaneous laboratory comparison. There were no significant night-night (all p > 0.10) or study order effects (home or laboratory first, p = 0.08) on AHI measures. Manual PM data review improved case finding accuracy, although this was not statistically significant (all p > 0.07). Misclassification was more frequent where OSA was mild. Overall performance of the PM device is consistent with current recommended criteria for an "acceptable" device to confidently "rule-in" OSA (AHI ≥ 5 events/h) in a high pretest probability clinic population. Our data support the utility of simple two-channel diagnostic devices to confirm the diagnosis of OSA in the home environment. A commentary on this article appears in this issue on page 411.
- 15 April 2015
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 11 (4) , 433-444
A Comprehensive Evaluation of a Two-Channel Portable Monitor to “Rule in” Obstructive Sleep Apnea
We hypothesized that a dual-channel portable monitor (PM) device could accurately identify patients who have a high pretest probability of obstructive sleep apnea (OSA), and we evaluated factors that may contribute to variability between PM and polysomnography (PSG) results. Consecutive clinic patients (N = 104) with possible OSA completed a home PM study, a PM study simultaneous with laboratory PSG, and a second home PM study. Uniform data analysis methods were applied to both PM and PSG data. Primary outcomes of interest were the positive likelihood ratio (LR+) and sensitivity of the PM device to "rule-in" OSA, defined as an apnea-hypopnea index (AHI) ≥ 5 events/h on PSG. Effects of different test environment and study nights, and order of study and analysis methods (manual compared to automated) on PM diagnostic accuracy were assessed. The PM has adequate LR+ (4.8), sensitivity (80%), and specificity (83%) for detecting OSA in the unattended home setting when benchmarked against laboratory PSG, with better LR+ (> 5) and specificity (100%) and unchanged sensitivity (80%) in the simultaneous laboratory comparison. There were no significant night-night (all p > 0.10) or study order effects (home or laboratory first, p = 0.08) on AHI measures. Manual PM data review improved case finding accuracy, although this was not statistically significant (all p > 0.07). Misclassification was more frequent where OSA was mild. Overall performance of the PM device is consistent with current recommended criteria for an "acceptable" device to confidently "rule-in" OSA (AHI ≥ 5 events/h) in a high pretest probability clinic population. Our data support the utility of simple two-channel diagnostic devices to confirm the diagnosis of OSA in the home environment. A commentary on this article appears in this issue on page 411.
- 15 October 2013
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 9 (10) , 1013-1021
Excessive Daytime Sleepiness Increases the Risk of Motor Vehicle Crash in Obstructive Sleep Apnea
(1) To describe the incidence rate of motor vehicle crashes (MVCs) in patients with obstructive sleep apnea (OSA); and (2) to investigate MVC risk factors in OSA patients. A retrospective case-series observational study was conducted using data from the West Australian Sleep Health Study at a tertiary hospital-based sleep clinic. Participants were patients (N = 2,673) referred for assessment of suspected sleep disordered breathing. Questionnaire data were collected including age, sex, years of driving, near-misses and MVCs, sleepiness, and consumption of alcohol and caffeinated drinks. Overnight laboratory-based polysomnography was performed using standard methodology.(1) Poisson univariate and negative binomial multivariable regression models were used to investigate associations between risk factors and MVC and near-miss risk in patients with untreated OSA. In patients with untreated OSA, the crash rate was 0.06 MVC/person-year compared with the general community crash rate of 0.02 MVC/person-year. The rate ratio comparing very sleepy men with normal men was 4.68 (95% CI 3.07, 7.14) for near-misses and 1.27 (95% CI 1.00, 1.61) for crashes, after adjusting for confounders. In women there was a significant association with sleepiness score (p = 0.02) but no dose effect across quartiles. Untreated OSA is associated with an increased risk of near-misses in men and women and an increased risk of MVCs in very sleepy men. There is a strong association between excessive daytime sleepiness and increased report of near-misses. Our data support the observation that it is those patients with increased sleepiness regardless of OSA severity who are most at risk.
- 15 October 2013
- Published by Springer Nature in Journal of Clinical Sleep Medicine
- Vol. 9 (10) , 1013-1021
Excessive Daytime Sleepiness Increases the Risk of Motor Vehicle Crash in Obstructive Sleep Apnea
(1) To describe the incidence rate of motor vehicle crashes (MVCs) in patients with obstructive sleep apnea (OSA); and (2) to investigate MVC risk factors in OSA patients. A retrospective case-series observational study was conducted using data from the West Australian Sleep Health Study at a tertiary hospital-based sleep clinic. Participants were patients (N = 2,673) referred for assessment of suspected sleep disordered breathing. Questionnaire data were collected including age, sex, years of driving, near-misses and MVCs, sleepiness, and consumption of alcohol and caffeinated drinks. Overnight laboratory-based polysomnography was performed using standard methodology.(1) Poisson univariate and negative binomial multivariable regression models were used to investigate associations between risk factors and MVC and near-miss risk in patients with untreated OSA. In patients with untreated OSA, the crash rate was 0.06 MVC/person-year compared with the general community crash rate of 0.02 MVC/person-year. The rate ratio comparing very sleepy men with normal men was 4.68 (95% CI 3.07, 7.14) for near-misses and 1.27 (95% CI 1.00, 1.61) for crashes, after adjusting for confounders. In women there was a significant association with sleepiness score (p = 0.02) but no dose effect across quartiles. Untreated OSA is associated with an increased risk of near-misses in men and women and an increased risk of MVCs in very sleepy men. There is a strong association between excessive daytime sleepiness and increased report of near-misses. Our data support the observation that it is those patients with increased sleepiness regardless of OSA severity who are most at risk.