Paolo Cigni
Research Subjects
Paolo Cigni has a total of 11 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro Cucini
Fisioclinic Dott. Paolo Cigni, Via Porta Massetana 1, 56045 Pomarance, PI, Italy
2 shared publications - Erika Cione
Department of Pharmacy, Health and Nutritional Sciences, University of Calabria, 87036 Rende, Italy
2 shared publications - Leonardo Ricotti
The BioRobotics Institute, Scuola Superiore Sant’Anna, Piazza Martiri della Libertà 33, 56127 Pisa, Italy
2 shared publications - Michele Costagli
Fisioclinic Dott. Paolo Cigni, Via Porta Massetana 1, 56045 Pomarance, PI, Italy
2 shared publications - Roberto Cannataro
Galascreen Laboratories, University of Calabria, 87036 Rende, Italy
2 shared publications - Stefano Rapetti
A.C. Milan, Via Aldo Rossi 8, 20149 Milano, Italy
2 shared publications
Latest Publications
- Open Access
- 5 October 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (4) , 141
Application of a Custom Device to Measure Isometric Knee Strength: Possible Injury Correlation in Professional Soccer (Football) Players
Injury in sports is an occurrence that prevents athletes from participating in training and competitions and has an incidence of 8.1 injuries/1000 h of practice. This translates into a cost and also into danger, especially if the event is repeated, for the health of the athlete; the injury certainly has a multifactorial causality. On the other hand, having instruments that can represent an alarm could be helpful for those involved in sports science. We used a specifically designed instrument, presented in a previous work, which shows excellent reliability and repeatability in measuring the strength of the knee flexors and extensors to test 107 players belonging to three different teams playing in the Italian Serie A. We took three measurements, beginning of the season, mid-season, and close to the end of the season. This retrospective study on 107 professional soccer players demonstrates that isometric force-related parameters of the knee extensors and flexors are associated with the risk of injury to lower limbs. Logistic regression evidenced a significant correlation between the parameter indicating the imbalance of the force between the flexors of the two limbs (, OR = 1.089) and the occurrence of injuries. Survival analyses ( evidenced a correlation between the population survival time and the injury incidence. We demonstrated that the analysis of the strength imbalance is correlated with injury occurrence, but it is well known that sports injuries are a multifactorial event; so, they cannot be predicted by only one parameter. However, the method proposed in this paper could represent a useful tool for sport scientists.- 5 October 2023
- Published by MDPI AG in Journal of Functional Morphology and Kinesiology
- Vol. 8 (4) , 141
Open AccessApplication of a Custom Device to Measure Isometric Knee Strength: Possible Injury Correlation in Professional Soccer (Football) Players
Injury in sports is an occurrence that prevents athletes from participating in training and competitions and has an incidence of 8.1 injuries/1000 h of practice. This translates into a cost and also into danger, especially if the event is repeated, for the health of the athlete; the injury certainly has a multifactorial causality. On the other hand, having instruments that can represent an alarm could be helpful for those involved in sports science. We used a specifically designed instrument, presented in a previous work, which shows excellent reliability and repeatability in measuring the strength of the knee flexors and extensors to test 107 players belonging to three different teams playing in the Italian Serie A. We took three measurements, beginning of the season, mid-season, and close to the end of the season. This retrospective study on 107 professional soccer players demonstrates that isometric force-related parameters of the knee extensors and flexors are associated with the risk of injury to lower limbs. Logistic regression evidenced a significant correlation between the parameter indicating the imbalance of the force between the flexors of the two limbs (, OR = 1.089) and the occurrence of injuries. Survival analyses ( evidenced a correlation between the population survival time and the injury incidence. We demonstrated that the analysis of the strength imbalance is correlated with injury occurrence, but it is well known that sports injuries are a multifactorial event; so, they cannot be predicted by only one parameter. However, the method proposed in this paper could represent a useful tool for sport scientists. - Open Access
Reliability of a Custom Device Used to Measure Isometric Knee Flexor and Extensor Strength in Standing Position
Background: Assessing lower limb strength in the field is problematic, as the “gold standard assessment” with isokinetic strength is cumbersome, and the device is costly and not transportable and keeps the angle of the hip at around 90°. Methods: We evaluated isometric muscle strength in a standing position with the help of an exoskeleton that holds the subject and makes the test easily repeatable. Results: The optimal device angles for hip and knee were, respectively, 20° and 80° for flexor tests and 30° and 40° for extensor tests. Test–retest reliability was very high for the right knee extensor (ICC 0.96–0.98), left knee extensor (ICC 0.96–0.97), right knee flexor (ICC 0.91–0.96), and left knee flexor (ICC 0.96–0.97). Furthermore, the typical error in percent (T.E.%) ranged from 2.50 to 5.50%, and the change in the mean in percent ranged from 0.84 to 7.72%, making it possible to determine even a slight variation in force. Conclusions: this new method could represent a valid alternative for assessing strength, due to the high reliability and the favorable joint position, particularly in football.
Open AccessReliability of a Custom Device Used to Measure Isometric Knee Flexor and Extensor Strength in Standing Position
Background: Assessing lower limb strength in the field is problematic, as the “gold standard assessment” with isokinetic strength is cumbersome, and the device is costly and not transportable and keeps the angle of the hip at around 90°. Methods: We evaluated isometric muscle strength in a standing position with the help of an exoskeleton that holds the subject and makes the test easily repeatable. Results: The optimal device angles for hip and knee were, respectively, 20° and 80° for flexor tests and 30° and 40° for extensor tests. Test–retest reliability was very high for the right knee extensor (ICC 0.96–0.98), left knee extensor (ICC 0.96–0.97), right knee flexor (ICC 0.91–0.96), and left knee flexor (ICC 0.96–0.97). Furthermore, the typical error in percent (T.E.%) ranged from 2.50 to 5.50%, and the change in the mean in percent ranged from 0.84 to 7.72%, making it possible to determine even a slight variation in force. Conclusions: this new method could represent a valid alternative for assessing strength, due to the high reliability and the favorable joint position, particularly in football.
- Open Access
- 9 April 2015
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 10 (1) , 14
Non invasive ventilation as an additional tool for exercise training
Recently, there has been increasing interest in the use of non invasive ventilation (NIV) to increase exercise capacity. In individuals with COPD, NIV during exercise reduces dyspnoea and increases exercise tolerance. Different modalities of mechanical ventilation have been used non-invasively as a tool to increase exercise tolerance in COPD, heart failure and lung and thoracic restrictive diseases. Inspiratory support provides symptomatic benefit by unloading the ventilatory muscles, whereas Continuous Positive Airway Pressure (CPAP) counterbalances the intrinsic positive end-expiratory pressure in COPD patients. Severe stable COPD patients undergoing home nocturnal NIV and daytime exercise training showed some benefits. Furthermore, it has been reported that in chronic hypercapnic COPD under long-term ventilatory support, NIV can also be administered during walking. Despite these results, the role of NIV as a routine component of pulmonary rehabilitation is still to be defined.
- 9 April 2015
- Published by Mattioli1885 in Multidisciplinary Respiratory Medicine
- Vol. 10 (1) , 14
Open AccessNon invasive ventilation as an additional tool for exercise training
Recently, there has been increasing interest in the use of non invasive ventilation (NIV) to increase exercise capacity. In individuals with COPD, NIV during exercise reduces dyspnoea and increases exercise tolerance. Different modalities of mechanical ventilation have been used non-invasively as a tool to increase exercise tolerance in COPD, heart failure and lung and thoracic restrictive diseases. Inspiratory support provides symptomatic benefit by unloading the ventilatory muscles, whereas Continuous Positive Airway Pressure (CPAP) counterbalances the intrinsic positive end-expiratory pressure in COPD patients. Severe stable COPD patients undergoing home nocturnal NIV and daytime exercise training showed some benefits. Furthermore, it has been reported that in chronic hypercapnic COPD under long-term ventilatory support, NIV can also be administered during walking. Despite these results, the role of NIV as a routine component of pulmonary rehabilitation is still to be defined.