Janarthanan Sathananthan
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Janarthanan Sathananthan has a total of 295 co-authors. Here are the top co-authors by number of shared publications:
David A. Wood
Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, Vancouver, Canada; Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
17 shared publications- David Meier
Department of Cardiology, Lausanne University Hospital and University of Lausanne, 1015 Lausanne, Switzerland
14 shared publications John G. Webb
Centre for Cardiovascular Innovation, St. Paul's and Vancouver General Hospital, Vancouver, Canada; Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
12 shared publications- Stephanie L. Sellers
Centre for Cardiovascular Innovation, University of British Columbia, Vancouver, BC V5Z 1M9, Canada
11 shared publications - Thomas Puehler
German Centre for Cardiovascular Research (DZHK), Partner Site North, 20251 Hamburg, Germany
11 shared publications - John G. Webb
Centre for Heart Valve Innovation, St. Paul's Hospital, University of British Columbia, Vancouver, British Columbia, Canada
10 shared publications
Latest Publications
- Open Access
- 28 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3794
Non-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation
Background/Objectives: Aortic valve stenosis (AS) is a prevalent cardiovascular condition among elderly patients frequently treated with Transcatheter Aortic Valve Implantation (TAVI). Traditional hemodynamic monitoring during TAVI relies on invasive methods. The ClearSight® Finger Cuff system offers a non-invasive alternative for continuous hemodynamic monitoring. To compare the reliability and feasibility of non-invasive hemodynamic monitoring with traditional invasive hemodynamic monitoring during TAVI procedures. Methods: In this prospective observational study, patients undergoing elective TAVI were recruited from two tertiary hospitals between March and August 2023. Invasive hemodynamic measurements were obtained using arterial and pigtail catheters, with a subset undergoing right heart catheterization. Non-invasive measurements were captured using the ClearSight® system. Data on baseline characteristics, procedural details, and 30-day follow-up outcomes were collected. Results: The study cohort comprised 50 patients (median age 82 years (IQR 78.0, 85.8), 50% female). Non-invasive measurements of cardiac output (CO), cardiac index (CI), and stroke volume (SV) were consistently lower than invasive measurements (CO: 4.1 vs. 4.8 L/min, p = 0.03; CI: 2.2 vs. 2.7 L/min/m2, p = 0.01, SV: 66 vs. 77 mL, p = 0.25). Non-invasive blood pressure readings were lower than invasive radial and aortic measurements before and after TAVI. Correlation of non- and invasive measurements was low but similar before and after TAVI (Mean percentage error of 52%). Conclusions: The ClearSight® system provided lower absolute values for all evaluated hemodynamic parameters as well as low correlation compared to traditional methods pre- as well as post-interventional.
- 28 May 2025
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 14 (11) , 3794
Open AccessNon-Invasive Hemodynamic Monitoring in Transcatheter Aortic Valve Implantation
Background/Objectives: Aortic valve stenosis (AS) is a prevalent cardiovascular condition among elderly patients frequently treated with Transcatheter Aortic Valve Implantation (TAVI). Traditional hemodynamic monitoring during TAVI relies on invasive methods. The ClearSight® Finger Cuff system offers a non-invasive alternative for continuous hemodynamic monitoring. To compare the reliability and feasibility of non-invasive hemodynamic monitoring with traditional invasive hemodynamic monitoring during TAVI procedures. Methods: In this prospective observational study, patients undergoing elective TAVI were recruited from two tertiary hospitals between March and August 2023. Invasive hemodynamic measurements were obtained using arterial and pigtail catheters, with a subset undergoing right heart catheterization. Non-invasive measurements were captured using the ClearSight® system. Data on baseline characteristics, procedural details, and 30-day follow-up outcomes were collected. Results: The study cohort comprised 50 patients (median age 82 years (IQR 78.0, 85.8), 50% female). Non-invasive measurements of cardiac output (CO), cardiac index (CI), and stroke volume (SV) were consistently lower than invasive measurements (CO: 4.1 vs. 4.8 L/min, p = 0.03; CI: 2.2 vs. 2.7 L/min/m2, p = 0.01, SV: 66 vs. 77 mL, p = 0.25). Non-invasive blood pressure readings were lower than invasive radial and aortic measurements before and after TAVI. Correlation of non- and invasive measurements was low but similar before and after TAVI (Mean percentage error of 52%). Conclusions: The ClearSight® system provided lower absolute values for all evaluated hemodynamic parameters as well as low correlation compared to traditional methods pre- as well as post-interventional.
- Open Access
- 31 May 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 104 (1) , 105-114
Bicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry
Background: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry.Aim: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves.Methods: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post‐TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area‐derived annular diameter, and performance of pre‐dilation and post‐dilation.Results: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post‐dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post‐dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post‐TAVR mean gradient (r = −0.324, p < 0.001).Conclusion: Relative stent expansion ≥90% was associated with the performance of post‐dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.
- 31 May 2024
- Published by Wiley in Catheterization and Cardiovascular Interventions
- Vol. 104 (1) , 105-114
Open AccessBicuspid valve CT registry of balloon‐expandable TAVR: BETTER TAVR registry
Background: The anatomic substrate of bicuspid valves may lead to suboptimal TAVR stent expansion and geometry.Aim: We evaluated determinants of stent geometry in bicuspid valves treated with Sapien transcatheter aortic valve replacement (TAVR) valves.Methods: A multicenter retrospective registry of patients (February 2019 to August 2022) who underwent post‐TAVR computed tomography to determine stent area (vs. nominal valve area) and stent ellipticity (maximum diameter/minimum diameter). Predictors of relative stent expansion (minimum area/average of inflow + outflow area) and stent ellipticity were evaluated in a multivariable regression model, including valve calcium volume (indexed by annular area), presence of raphe calcium, sinus diameters indexed by area‐derived annular diameter, and performance of pre‐dilation and post‐dilation.Results: The registry enrolled 101 patients from four centers. The minimum stent area (vs. nominal area) was 88.1%, and the maximum ellipticity was 1.10, with both observed near the midframe of the valve in all cases. Relative stent expansion ≥90% was observed in 64/101 patients. The only significant predictor of relative stent expansion ≥90% was the performance of post‐dilation (OR: 4.79, p = 0.018). Relative stent expansion ≥90% was seen in 86% of patients with post‐dilation compared to 57% without (p < 0.001). The stent ellipticity ≥1.1 was observed in 47/101 patients. The significant predictors of stent ellipticity ≥1.1 were the indexed maximum sinus diameter (OR: 0.582, p = 0.021) and indexed intercommisural diameter at 4 mm (OR: 2.42, p = 0.001). Stent expansion has a weak negative correlation with post‐TAVR mean gradient (r = −0.324, p < 0.001).Conclusion: Relative stent expansion ≥90% was associated with the performance of post‐dilation, and stent ellipticity ≥1.1 was associated with indexed intercommisural diameter and indexed maximum sinus diameter. Further studies to determine optimal deployment strategies in bicuspid valves are needed.
- Open Access
- 4 April 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (7) , 4026
Optimization of Enzymatic and Chemical Decellularization of Native Porcine Heart Valves for the Generation of Decellularized Xenografts
One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient’s immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve’s ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.
- 4 April 2024
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 25 (7) , 4026
Open AccessOptimization of Enzymatic and Chemical Decellularization of Native Porcine Heart Valves for the Generation of Decellularized Xenografts
One of the most important medical interventions for individuals with heart valvular disease is heart valve replacement, which is not without substantial challenges, particularly for pediatric patients. Due to their biological properties and biocompatibility, natural tissue-originated scaffolds derived from human or animal sources are one type of scaffold that is widely used in tissue engineering. However, they are known for their high potential for immunogenicity. Being free of cells and genetic material, decellularized xenografts, consequently, have low immunogenicity and, thus, are expected to be tolerated by the recipient’s immune system. The scaffold ultrastructure and ECM composition can be affected by cell removal agents. Therefore, applying an appropriate method that preserves intact the structure of the ECM plays a critical role in the final result. So far, there has not been an effective decellularization technique that preserves the integrity of the heart valve’s ultrastructure while securing the least amount of genetic material left. This study demonstrates a new protocol with untraceable cells and residual DNA, thereby maximally reducing any chance of immunogenicity. The mechanical and biochemical properties of the ECM resemble those of native heart valves. Results from this study strongly indicate that different critical factors, such as ionic detergent omission, the substitution of Triton X-100 with Tergitol, and using a lower concentration of trypsin and a higher concentration of DNase and RNase, play a significant role in maintaining intact the ultrastructure and function of the ECM.
- Open Access
- 4 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1474
Tricuspid Regurgitation and TAVR: Outcomes, Risk Factors and Biomarkers
Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.
- 4 March 2024
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 13 (5) , 1474
Open AccessTricuspid Regurgitation and TAVR: Outcomes, Risk Factors and Biomarkers
Background. The significance of concomitant tricuspid regurgitation (TR) in the context of transcatheter aortic valve replacement (TAVR) remains unclear. This study aimed to analyze the severity of TR before and after TAVR with regard to short- and long-term survival and to analyze the influencing factors. Methods. In our retrospective analysis, TR before and after TAVR was examined and patients were classified into groups accordingly. Special attention was paid to patients with post-interventional changes in TR. Mortality after TAVR was considered the primary endpoint of the analysis and major complications according to the Valve Academic Research Consortium 3 (VARC3) were compared. Moreover, biomarkers and risk factors for worsening or improvement of TR through TAVR were analyzed. Results. Among 775 patients who underwent TAVR in our center between January 2009 and December 2019, 686 patients (89%) featured low- and 89 patients (11%) high-grade TR. High-grade pre-TAVR TR was associated with worse short- (30-day), mid- (2-year) and long-term survival up to 8 years. Even though in nearly half of the patients with high-grade TR the regurgitation improved within seven days after TAVR (n = 42/89), this did not result in a survival benefit for this subgroup. On the other hand, a worsening of low-grade TR was seen in more than 10% of the patients (n = 73/686), which was also associated with a worse prognosis. Predictors of worsening of TR after TAVR were adipositas, impaired right ventricular function and the presence of mild TR. Age, atrial fibrillation, COPD, impaired renal function and elevated cardiac biomarkers were risk factors for mortality after TAVR independent from the grade of TR. Conclusions. Not only pre-interventional, but also post-TAVR high-grade TR is associated with a worse prognosis after TAVR. TAVR can change concomitant tricuspid regurgitation, but improvement does not have any impact on short- and long-term survival. Worsening of TR after TAVR is possible and impairs the prognosis.
- Open Access
- 11 December 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (24) , 17357
Producing and Testing Prototype Tissue-Engineered 3D Tri-Leaflet Valved Stents on Biodegradable Poly-ε-Caprolactone Scaffolds
Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.
- 11 December 2023
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 24 (24) , 17357
Open AccessProducing and Testing Prototype Tissue-Engineered 3D Tri-Leaflet Valved Stents on Biodegradable Poly-ε-Caprolactone Scaffolds
Transcatheter pulmonary valve replacement is a minimally-invasive alternative treatment for right ventricular outflow tract dysfunction and has been rapidly evolving over the past years. Heart valve prostheses currently available still have major limitations. Therefore, one of the significant challenges for the future is the roll out of transcatheter tissue engineered pulmonary valve replacement to more patients. In the present study, biodegradable poly-ε-caprolactone (PCL) nanofiber scaffolds in the form of a 3D leaflet matrix were successfully seeded with human endothelial colony-forming cells (ECFCs), human induced pluripotent stem cell-derived MSCs (hMSCs), and porcine MSCs (pMSCs) for three weeks for the generation of 3D tissue-engineered tri-leaflet valved stent grafts. The cell adhesion, proliferation, and distribution of these 3D heart leaflets was analyzed using fluorescence microscopy and scanning electron microscopy (SEM). All cell lineages were able to increase the overgrown leaflet area within the three-week timeframe. While hMSCs showed a consistent growth rate over the course of three weeks, ECFSs showed almost no increase between days 7 and 14 until a growth spurt appeared between days 14 and 21. More than 90% of heart valve leaflets were covered with cells after the full three-week culturing cycle in nearly all leaflet areas, regardless of which cell type was used. This study shows that seeded biodegradable PCL nanofiber scaffolds incorporated in nitinol or biodegradable stents will offer a new therapeutic option in the future.
- Open Access
- 1 November 2023
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 16 (11) , e013238
Feasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study
BACKGROUND: Coronary accessibility following redo–transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 ( P P P P <0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02701283.
- 1 November 2023
- Published by Wolters Kluwer Health in Circulation: Cardiovascular Interventions
- Vol. 16 (11) , e013238
Open AccessFeasibility of Coronary Access Following Redo-TAVR for Evolut Failure: A Computed Tomography Simulation Study
BACKGROUND: Coronary accessibility following redo–transcatheter aortic valve replacement (redo-TAVR) is increasingly important, particularly in younger low-risk patients. This study aimed to predict coronary accessibility after simulated Sapien-3 balloon-expandable valve implantation within an Evolut supra-annular, self-expanding valve using pre-TAVR computed tomography (CT) imaging. METHODS: A total of 219 pre-TAVR CT scans from the Evolut Low-Risk CT substudy were analyzed. Virtual Evolut and Sapien-3 valves were sized using CT-based diameters. Two initial Evolut implant depths were analyzed, 3 and 5 mm. Coronary accessibility was evaluated for 2 Sapien-3 in Evolut implant positions: Sapien-3 outflow at Evolut node 4 and Evolut node 5. RESULTS: With a 3-mm initial Evolut implant depth, suitable coronary access was predicted in 84% of patients with the Sapien-3 outflow at Evolut node 4, and in 31% of cases with the Sapien-3 outflow at Evolut node 5 ( P P P P <0.001). CONCLUSIONS: Coronary accessibility after Sapien-3 in Evolut redo-TAVR relates to the initial Evolut implant depth, the Sapien-3 outflow position within the Evolut, and the native annular anatomy. This CT-based quantitative analysis may provide useful information to inform and refine individualized preprocedural CT planning of the initial TAVR and guide lifetime management for future coronary access after redo-TAVR. REGISTRATION: URL: https://www.clinicaltrials.gov ; Unique identifier: NCT02701283.
- 10 October 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (11) , 1425-1431
TAVR in TAVR: Where Are We in 2023 for Management of Failed TAVR Valves?
Purpose of Review As TAVR is increasingly performed on younger patients with a longer life expectancy, the number of redo-TAVR procedures is likely to increase in the coming years. Limited data is currently available on this sometimes challenging procedure. We provide a summary of currently published literature on management of patients with a failed transcatheter aortic valve. Recent Findings Recent registry data have increased the clinical knowledge on redo-TAVR. Additionally, numerous bench studies have provided valuable insights into the technical aspects of redo-TAVR with various combinations of valve types. Summary Redo-TAVR can be performed safely in selected cases with a high procedural success and good short-term outcomes. However, at present, the procedure remains relatively infrequent and many patients are not eligible. Bench testing can be useful to understand important concepts such as valve expansion, neoskirt, leaflet overhang, and leaflet deflection as well as their potential clinical implications.
- 10 October 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (11) , 1425-1431
TAVR in TAVR: Where Are We in 2023 for Management of Failed TAVR Valves?
Purpose of Review As TAVR is increasingly performed on younger patients with a longer life expectancy, the number of redo-TAVR procedures is likely to increase in the coming years. Limited data is currently available on this sometimes challenging procedure. We provide a summary of currently published literature on management of patients with a failed transcatheter aortic valve. Recent Findings Recent registry data have increased the clinical knowledge on redo-TAVR. Additionally, numerous bench studies have provided valuable insights into the technical aspects of redo-TAVR with various combinations of valve types. Summary Redo-TAVR can be performed safely in selected cases with a high procedural success and good short-term outcomes. However, at present, the procedure remains relatively infrequent and many patients are not eligible. Bench testing can be useful to understand important concepts such as valve expansion, neoskirt, leaflet overhang, and leaflet deflection as well as their potential clinical implications.
- 12 September 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (10) , 1361-1371
Update on Transcatheter Treatment of Mitral and Tricuspid Valve Regurgitation
Purpose of Review Mitral and tricuspid regurgitation represents a clinical challenge. They are associated with a poor prognosis, and many patients are not eligible for conventional surgery. Transcatheter therapies have been the focus of numerous studies and devices over the past decade. Here, we provide a summary of current options for transcatheter treatment of these 2 entities. Recent Findings Recent studies have demonstrated the benefits of edge-to-edge repair for increasing numbers of patients. Encouraging early results with transcatheter valve replacement are also becoming available. Summary To date, transcatheter edge-to-edge repair is currently the first-line transcatheter treatment for both mitral and tricuspid regurgitation for many patients who are not candidates for surgery. A number of transcatheter replacement devices are under development and clinical investigation but, for the most part, their current use is limited to compassionate cases or clinical trials.
- 12 September 2023
- Published by Springer Nature in Current Cardiology Reports
- Vol. 25 (10) , 1361-1371
Update on Transcatheter Treatment of Mitral and Tricuspid Valve Regurgitation
Purpose of Review Mitral and tricuspid regurgitation represents a clinical challenge. They are associated with a poor prognosis, and many patients are not eligible for conventional surgery. Transcatheter therapies have been the focus of numerous studies and devices over the past decade. Here, we provide a summary of current options for transcatheter treatment of these 2 entities. Recent Findings Recent studies have demonstrated the benefits of edge-to-edge repair for increasing numbers of patients. Encouraging early results with transcatheter valve replacement are also becoming available. Summary To date, transcatheter edge-to-edge repair is currently the first-line transcatheter treatment for both mitral and tricuspid regurgitation for many patients who are not candidates for surgery. A number of transcatheter replacement devices are under development and clinical investigation but, for the most part, their current use is limited to compassionate cases or clinical trials.
- Open Access
- 23 August 2023
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 23 (3) , 296-304
Early mobilization after transcatheter aortic valve implantation: observational cohort study
Early mobilisation is associated with improved outcomes in hospitalised older patients. We sought to determine the effect of a nurse-led protocol on mobilisation 4 hours after transfemoral transcatheter aortic valve implantation (TAVI) across different units of care. We conducted a prospective observational cohort single centre study of consecutive patients. We implemented a standardised protocol for safe early recovery and progressive mobilisation in the critical care and cardiac telemetry units. We measured time to first mobilisation and conducted descriptive statistics to identify patient and systems barriers to timely ambulation. We recruited 139 patients (82.5 years, SD = 6.7; 46% women). At baseline, patients who mobilized early (≤4 hours) and late (>4 hours) did not differ, except for higher rates of diabetes (25.5% vs. 43.9%, p = 0.032) and peripheral arterial disease (8.2% vs. 26.8%, p = 0.003) in the late mobilisation group. Median time to mobilisation was 4 hours (IQR 3.25, 4); 98 patients (70.5%) were mobilized successfully after 4 hours of bedrest; 118 (84.9%) were walking by the evening of the procedure (< 8 hours bedrest), and 21 (15.1%) were on bedrest overnight and mobilised the following day. Primary reasons for overnight bedrest were arrhythmia monitoring (n = 10, 7.2%) and hemodynamic and/or neurological instability (n = 6, 4.3%); 6 patients (4.3%) experienced delayed ambulation due to systems issues. Procedure location in the hybrid operating room and transfer to critical care were associated with longer bedrest times. Standardised nurse-led mobilisation 4 hours after TF TAVI is feasible in the absence of clinical complications and system barriers.
- 23 August 2023
- Published by Oxford University Press (OUP) in European Journal of Cardiovascular Nursing
- Vol. 23 (3) , 296-304
Open AccessEarly mobilization after transcatheter aortic valve implantation: observational cohort study
Early mobilisation is associated with improved outcomes in hospitalised older patients. We sought to determine the effect of a nurse-led protocol on mobilisation 4 hours after transfemoral transcatheter aortic valve implantation (TAVI) across different units of care. We conducted a prospective observational cohort single centre study of consecutive patients. We implemented a standardised protocol for safe early recovery and progressive mobilisation in the critical care and cardiac telemetry units. We measured time to first mobilisation and conducted descriptive statistics to identify patient and systems barriers to timely ambulation. We recruited 139 patients (82.5 years, SD = 6.7; 46% women). At baseline, patients who mobilized early (≤4 hours) and late (>4 hours) did not differ, except for higher rates of diabetes (25.5% vs. 43.9%, p = 0.032) and peripheral arterial disease (8.2% vs. 26.8%, p = 0.003) in the late mobilisation group. Median time to mobilisation was 4 hours (IQR 3.25, 4); 98 patients (70.5%) were mobilized successfully after 4 hours of bedrest; 118 (84.9%) were walking by the evening of the procedure (< 8 hours bedrest), and 21 (15.1%) were on bedrest overnight and mobilised the following day. Primary reasons for overnight bedrest were arrhythmia monitoring (n = 10, 7.2%) and hemodynamic and/or neurological instability (n = 6, 4.3%); 6 patients (4.3%) experienced delayed ambulation due to systems issues. Procedure location in the hybrid operating room and transfer to critical care were associated with longer bedrest times. Standardised nurse-led mobilisation 4 hours after TF TAVI is feasible in the absence of clinical complications and system barriers.
- Open Access
- 10 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5211
Transcatheter Aortic Valve Implantation by Intercostal Access: Initial Experience with a No-Touch Technique
Background: Transcatheter aortic valve implantation (TAVI) is now a well-established therapeutic option in an elderly high-risk patient cohort with aortic valve disease. Although most commonly performed via a transfemoral route, alternative approaches for TAVI are constantly being improved. Instead of the classical mini-sternotomy, it is possible to achieve a transaortic access via a right anterior mini-thoracotomy in the second intercostal space. We describe our experience with this sternum- and rib-sparing technique in comparison to the classical transaortic approach. Methods: Our retrospective study includes 173 patients who were treated in our institution between January 2017 and April 2020 with transaortic TAVI via either upper mini-sternotomy or intercostal thoracotomy. The primary endpoint was 30-day mortality, and secondary endpoints were defined as major postoperative complications that included admission to the intensive care unit and overall hospital stay, according to the Valve Academic Research Consortium 3. Results: Eighty-two patients were treated with TAo-TAVI by upper mini-sternotomy, while 91 patients received the intercostal approach. Both groups were comparable in age (mean age: 82 years) and in the proportion of female patients. The intercostal group had a higher rate of peripheral artery disease (41% vs. 22%, p = 0.008) and coronary artery disease (71% vs. 40%, p < 0.001) with a history of percutaneous coronary intervention or coronary artery bypass grafting, resulting in significantly higher preinterventional risk evaluation (EuroScore II 8% in the intercostal vs. 4% in the TAo group, p = 0.005). Successful device implantation and a reduction of the transvalvular gradient were achieved in all cases with a significantly lower rate of trace to mild paravalvular leakage in the intercostal group (12% vs. 33%, p < 0.001). The intercostal group required significantly fewer blood transfusions (0 vs. 2 units, p = 0.001) and tended to require less reoperation (7% vs. 15%, p = 0.084). Hospital stays (9 vs. 12 d, p = 0.011) were also shorter in the intercostal group. Short- and long-term survival in the follow-up showed comparable results between the two approaches (30-day, 6-month- and 2-year mortality: 7%, 23% and 36% in the intercostal vs. 9%, 26% and 33% in the TAo group) with acute kidney injury (AKI) and reintubation being independent risk factors for mortality. Conclusions: Transaortic TAVI via an intercostal access offers a safe and effective treatment of aortic valve stenosis.
- 10 August 2023
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 12 (16) , 5211
Open AccessTranscatheter Aortic Valve Implantation by Intercostal Access: Initial Experience with a No-Touch Technique
Background: Transcatheter aortic valve implantation (TAVI) is now a well-established therapeutic option in an elderly high-risk patient cohort with aortic valve disease. Although most commonly performed via a transfemoral route, alternative approaches for TAVI are constantly being improved. Instead of the classical mini-sternotomy, it is possible to achieve a transaortic access via a right anterior mini-thoracotomy in the second intercostal space. We describe our experience with this sternum- and rib-sparing technique in comparison to the classical transaortic approach. Methods: Our retrospective study includes 173 patients who were treated in our institution between January 2017 and April 2020 with transaortic TAVI via either upper mini-sternotomy or intercostal thoracotomy. The primary endpoint was 30-day mortality, and secondary endpoints were defined as major postoperative complications that included admission to the intensive care unit and overall hospital stay, according to the Valve Academic Research Consortium 3. Results: Eighty-two patients were treated with TAo-TAVI by upper mini-sternotomy, while 91 patients received the intercostal approach. Both groups were comparable in age (mean age: 82 years) and in the proportion of female patients. The intercostal group had a higher rate of peripheral artery disease (41% vs. 22%, p = 0.008) and coronary artery disease (71% vs. 40%, p < 0.001) with a history of percutaneous coronary intervention or coronary artery bypass grafting, resulting in significantly higher preinterventional risk evaluation (EuroScore II 8% in the intercostal vs. 4% in the TAo group, p = 0.005). Successful device implantation and a reduction of the transvalvular gradient were achieved in all cases with a significantly lower rate of trace to mild paravalvular leakage in the intercostal group (12% vs. 33%, p < 0.001). The intercostal group required significantly fewer blood transfusions (0 vs. 2 units, p = 0.001) and tended to require less reoperation (7% vs. 15%, p = 0.084). Hospital stays (9 vs. 12 d, p = 0.011) were also shorter in the intercostal group. Short- and long-term survival in the follow-up showed comparable results between the two approaches (30-day, 6-month- and 2-year mortality: 7%, 23% and 36% in the intercostal vs. 9%, 26% and 33% in the TAo group) with acute kidney injury (AKI) and reintubation being independent risk factors for mortality. Conclusions: Transaortic TAVI via an intercostal access offers a safe and effective treatment of aortic valve stenosis.