Eun-Ung Lee
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Eun-Ung Lee has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Hyun-Chang Lim
Clinic of Reconstructive Dentistry, Center of Dental Medicine University of Zurich Zurich Switzerland
2 shared publications - Jung-Seok Lee
Department of Periodontology, Research Institute for Periodontal Regeneration, College of Dentistry Yonsei University Seoul South Korea
2 shared publications - Seong-Ho Choi
Department of Chemistry, Hannam University, Yuseong-gu, Daejeon 34054, Republic of Korea
2 shared publications - Ui-Won Jung
Department of Periodontology, Research Institute for Periodontal Regeneration Yonsei University College of Dentistry Seoul Korea
2 shared publications - Bum-Chul Kim
Department of Chemical and Biomolecular Engineering, Seoul National University of Science and Technology, 232 Gongneung-ro, Nowon-gu, Seoul, 139-743 Republic of South Korea
1 shared publication - Dong-Ju Kim
Department of Periodontology, Research Institute for Periodontal Regeneration, College of Dentistry, Yonsei University, 50 Yonsei-ro, Seodaemun-gu, Seoul South Korea
1 shared publication
Latest Publications
- Open Access
- 12 February 2015
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 19 (1) , 1
Comparative evaluation of biphasic calcium phosphate and biphasic calcium phosphate collagen composite on osteoconductive potency in rabbit calvarial defect
Background: The aim of this study was to determine the osteoconductivity of biphasic calcium phosphate collagen composite (BCPC) in rabbit calvarial defect model by comparing with biphasic calcium phosphate (BCP). Four 8 mm diameter bicortical calvarial defects were made in ten rabbits. Each of the defects was randomly assigned and filled with 1) collagen sponge, 2) BCP, 3) BCPC, and 4) nothing as control. The animals were sacrificed at either 2 weeks (n = 5) or 8 weeks (n = 5) healing period. Results: All groups showed wedge shaped new bone formation limited to the area of the defect margin at both healing periods. The amounts of new bone and defect closure were similar among all groups. In the control and collagen sponge group, the center of the defect was depressed by surrounding tissues. In contrast, in BCP and BCPC group, the center of the defect did not depressed and the grafted materials maintained the space. And the augmented area was significantly higher in BCP and BCPC group compared to the control and collagen sponge group at both healing periods (p < 0.05). Conclusions: The BCPC and BCP demonstrated proper space maintaining capacity and osteoconductive property, suggesting BCPC can be efficiently utilized in various clinical situations.
- 12 February 2015
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 19 (1) , 1
Open AccessComparative evaluation of biphasic calcium phosphate and biphasic calcium phosphate collagen composite on osteoconductive potency in rabbit calvarial defect
Background: The aim of this study was to determine the osteoconductivity of biphasic calcium phosphate collagen composite (BCPC) in rabbit calvarial defect model by comparing with biphasic calcium phosphate (BCP). Four 8 mm diameter bicortical calvarial defects were made in ten rabbits. Each of the defects was randomly assigned and filled with 1) collagen sponge, 2) BCP, 3) BCPC, and 4) nothing as control. The animals were sacrificed at either 2 weeks (n = 5) or 8 weeks (n = 5) healing period. Results: All groups showed wedge shaped new bone formation limited to the area of the defect margin at both healing periods. The amounts of new bone and defect closure were similar among all groups. In the control and collagen sponge group, the center of the defect was depressed by surrounding tissues. In contrast, in BCP and BCPC group, the center of the defect did not depressed and the grafted materials maintained the space. And the augmented area was significantly higher in BCP and BCPC group compared to the control and collagen sponge group at both healing periods (p < 0.05). Conclusions: The BCPC and BCP demonstrated proper space maintaining capacity and osteoconductive property, suggesting BCPC can be efficiently utilized in various clinical situations.
- Open Access
- 24 July 2014
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 18 (1) , 12
Biocompatibility and resorption pattern of newly developed hyaluronic acid hydrogel reinforced three-layer poly (lactide-co-glycolide) membrane: histologic observation in rabbit calvarial defect model
Background: The aim of this study was to evaluate the biocompatibility and resorption pattern in three-layer poly (lactide-co-glycolide) (PLGA) membrane according to the concentrations of hyaluronic acid (HA) hydrogel in rabbit calvarial defect model. Four standardized circular defects with 8 mm diameter were created on the four rabbit calvarium. Three-layer PLGA membranes (5% and 10% HA gel) were used as the test groups, both collagen membrane and monolayer PLGA membrane as the control groups. Results: After sacrificing the animals after 4 and 8 weeks, block sections were harvested and histological observation was performed. Pus formation was observed in a site on the three-layer PLGA membranes (with 10% HA gel) of 4 weeks group and initial inflammatory responses were observed on the three-layer PLGA membrane group. However, when compared to both the monolayer PLGA membrane group and collagen membrane group, the HA gel-reinforced three-layer PLGA membrane showed improved cell occlusion and retention period, showing the formation of the capsule-like structure. There was no definite difference between the results of the membranes fabricated with either 5% or 10% HA hydrogel. Conclusion: The HA reinforced three-layer PGLA membrane was retained longer than control group and showed good property in cell occlusion. Future study is under process to improve the inflammatory response of the three layer PLGA membranes, which were observed in this study.
- 24 July 2014
- Published by American Association for the Advancement of Science (AAAS) in Biomaterials Research
- Vol. 18 (1) , 12
Open AccessBiocompatibility and resorption pattern of newly developed hyaluronic acid hydrogel reinforced three-layer poly (lactide-co-glycolide) membrane: histologic observation in rabbit calvarial defect model
Background: The aim of this study was to evaluate the biocompatibility and resorption pattern in three-layer poly (lactide-co-glycolide) (PLGA) membrane according to the concentrations of hyaluronic acid (HA) hydrogel in rabbit calvarial defect model. Four standardized circular defects with 8 mm diameter were created on the four rabbit calvarium. Three-layer PLGA membranes (5% and 10% HA gel) were used as the test groups, both collagen membrane and monolayer PLGA membrane as the control groups. Results: After sacrificing the animals after 4 and 8 weeks, block sections were harvested and histological observation was performed. Pus formation was observed in a site on the three-layer PLGA membranes (with 10% HA gel) of 4 weeks group and initial inflammatory responses were observed on the three-layer PLGA membrane group. However, when compared to both the monolayer PLGA membrane group and collagen membrane group, the HA gel-reinforced three-layer PLGA membrane showed improved cell occlusion and retention period, showing the formation of the capsule-like structure. There was no definite difference between the results of the membranes fabricated with either 5% or 10% HA hydrogel. Conclusion: The HA reinforced three-layer PGLA membrane was retained longer than control group and showed good property in cell occlusion. Future study is under process to improve the inflammatory response of the three layer PLGA membranes, which were observed in this study.