Changqing Chen
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Changqing Chen has a total of 14 co-authors. Here are the top co-authors by number of shared publications:
- An-Qi Yang
Department of Biomaterials, College of Materials, Xiamen University, Xiamen, 361005, People’s Republic of China
1 shared publication - Dong Wang
Biomat Lab, Department of Mechanical Engineering, National University of Singapore, 117576, Singapore; Department of Orthopedic Surgery, Yong Loo Lin School of Medicine, National University of Singapore, 119228, Singapore
1 shared publication - Donghui Li
College of Medicine, Xiamen University, Xiamen, 361005, People’s Republic of China
1 shared publication Guofeng Huang
Department of Orthopaedic Surgery, Orthopaedic Center of PLA, Affiliated Southeast Hospital of Xiamen University, Zhangzhou, PR China
1 shared publicationGuojun Liu
Department of Orthopaedic Surgery, Orthopaedic Center of PLA, Affiliated Southeast Hospital of Xiamen University, Zhangzhou, PR China
1 shared publication- Hongjun Wang
Stevens Institute of Technology
1 shared publication
Latest Publications
- 10 July 2016
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 31 (2) , 241-249
A biodegradable antibiotic-eluting PLGA nanofiber-loaded deproteinized bone for treatment of infected rabbit bone defects
We fabricated a biodegradable antibiotic-eluting poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (ANDB) scaffold that provided sustained delivery of vancomycin to repair methicillin-resistant Staphylococcus aureus bone defects. To fabricate the biodegradable ANDB, poly(d,l)-lactide-co-glycolide and vancomycin were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propano. The solution was then electrospun to produce biodegradable antibiotic-eluting membranes that were deposited on the surface of bovine deproteinized cancellous bone. We used scanning electron microscopy to determine the properties of the scaffold. Both elution and high-performance liquid chromatography assays were used to evaluate the in vitro vancomycin release rate from the ANDB scaffold. Three types of scaffolds were co-cultured with bacteria to confirm the in vitro antibacterial activity. The infected bone defect rabbit model was induced by injecting 107 colony forming units of a methicillin-resistant Staphylococcus aureus strain into the radial defect of rabbits. Animals were then separated into treatment groups and implanted according to the following scheme: ANDB scaffold in group A, poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (NDB) scaffold with intravenous (i.v.) vancomycin in group B, and NDB scaffold alone in group C. Treatment efficacy was evaluated after eight weeks using radiological, microbiological, and histological examinations. In vitro results revealed that biodegradable ANDB scaffolds released concentrations of vancomycin that were greater than the minimum inhibitory concentration for more than four weeks. Bacterial inhibition tests also confirmed antibacterial efficacy lasted for approximately four weeks. Radiological and histological scores obtained in vivo revealed significant differences between groups A, B and C. Importantly, group A had significantly lower bacterial load and better bone regeneration when compared to either group B or C. Collectively, these results show that our fabricated ANDB scaffolds possess: (1) effective bactericidal activity against methicillin-resistant Staphylococcus aureus, (2) the ability to promote site-specific bone regeneration, and (3) the potential for use in the treatment of infected bone defects.
- 10 July 2016
- Published by SAGE Publications in Journal of Biomaterials Applications
- Vol. 31 (2) , 241-249
A biodegradable antibiotic-eluting PLGA nanofiber-loaded deproteinized bone for treatment of infected rabbit bone defects
We fabricated a biodegradable antibiotic-eluting poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (ANDB) scaffold that provided sustained delivery of vancomycin to repair methicillin-resistant Staphylococcus aureus bone defects. To fabricate the biodegradable ANDB, poly(d,l)-lactide-co-glycolide and vancomycin were first dissolved in 1,1,1,3,3,3-hexafluoro-2-propano. The solution was then electrospun to produce biodegradable antibiotic-eluting membranes that were deposited on the surface of bovine deproteinized cancellous bone. We used scanning electron microscopy to determine the properties of the scaffold. Both elution and high-performance liquid chromatography assays were used to evaluate the in vitro vancomycin release rate from the ANDB scaffold. Three types of scaffolds were co-cultured with bacteria to confirm the in vitro antibacterial activity. The infected bone defect rabbit model was induced by injecting 107 colony forming units of a methicillin-resistant Staphylococcus aureus strain into the radial defect of rabbits. Animals were then separated into treatment groups and implanted according to the following scheme: ANDB scaffold in group A, poly(d,l)-lactide-co-glycolide nanofiber-loaded deproteinized bone (NDB) scaffold with intravenous (i.v.) vancomycin in group B, and NDB scaffold alone in group C. Treatment efficacy was evaluated after eight weeks using radiological, microbiological, and histological examinations. In vitro results revealed that biodegradable ANDB scaffolds released concentrations of vancomycin that were greater than the minimum inhibitory concentration for more than four weeks. Bacterial inhibition tests also confirmed antibacterial efficacy lasted for approximately four weeks. Radiological and histological scores obtained in vivo revealed significant differences between groups A, B and C. Importantly, group A had significantly lower bacterial load and better bone regeneration when compared to either group B or C. Collectively, these results show that our fabricated ANDB scaffolds possess: (1) effective bactericidal activity against methicillin-resistant Staphylococcus aureus, (2) the ability to promote site-specific bone regeneration, and (3) the potential for use in the treatment of infected bone defects.
- Open Access
- 10 December 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 666
Co-enhancement of fluorescence and singlet oxygen generation by silica-coated gold nanorods core-shell nanoparticle
Metal-enhanced fluorescence (MEF) as a newly recognized technology has been attracting considerable attention and is widely used in fluorescence-based technology. In this paper, we reported a novel distance-dependent MEF and metal-enhanced singlet oxygen generation phenomenon based on silica-coated gold nanorods (AuNRs@SiO2) core-shell structure with tetra-substituted carboxyl aluminum phthalocyanine (AlC4Pc) that serve as both fluorophore and photosensitizer. When the AlC4Pc was linked on the surface of AuNRs@SiO2, the fluorescence intensity and singlet oxygen productivity varied with the thickness difference of silica shell from 2.1 to 28.6 nm. The co-enhancement effect reached the maximum of 7-fold and 2.1-fold, respectively, when the separation distance was 10.6 nm. These unique characteristics make the prepared core-shell nanoparticles promising for MEF-based biological imaging and photodynamics therapy.
- 10 December 2014
- Published by Springer Nature in Discover Nano
- Vol. 9 (1) , 666
Open AccessCo-enhancement of fluorescence and singlet oxygen generation by silica-coated gold nanorods core-shell nanoparticle
Metal-enhanced fluorescence (MEF) as a newly recognized technology has been attracting considerable attention and is widely used in fluorescence-based technology. In this paper, we reported a novel distance-dependent MEF and metal-enhanced singlet oxygen generation phenomenon based on silica-coated gold nanorods (AuNRs@SiO2) core-shell structure with tetra-substituted carboxyl aluminum phthalocyanine (AlC4Pc) that serve as both fluorophore and photosensitizer. When the AlC4Pc was linked on the surface of AuNRs@SiO2, the fluorescence intensity and singlet oxygen productivity varied with the thickness difference of silica shell from 2.1 to 28.6 nm. The co-enhancement effect reached the maximum of 7-fold and 2.1-fold, respectively, when the separation distance was 10.6 nm. These unique characteristics make the prepared core-shell nanoparticles promising for MEF-based biological imaging and photodynamics therapy.