Daniel S Cormican
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Research Interests
Daniel S Cormican has a total of 3 co-authors. Here are the top co-authors by number of shared publications:
- Catalin S. Ezaru
University of Pittsburgh School of Medicine, Veterans’ Affairs Hospital Pittsburgh
1 shared publication - James W. Ibinson
Department of Anesthesiology and Perioperative Medicine, School of Medicine; and Clinical and Translational Science Institute, University of Pittsburgh, Pittsburgh, Pennsylvania; Department of Anesthesiology, Surgical Service Line, Veterans Affairs Pittsburgh Healthcare System, Pittsburgh, Pennsylvania
1 shared publication - Michael P. Mangione
University of Pittsburgh School of Medicine
1 shared publication
Latest Publications
- Open Access
- 5 November 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 101
GlideScope Use improves intubation success rates: an observational study using propensity score matching
Rigid video laryngoscopes are popular alternatives to direct laryngoscopy for intubation, but further large scale prospective studies comparing these devices to direct laryngoscopy in routine anesthesiology practice are needed. We hypothesized that the first pass success rate with one particular video laryngoscope, the GlideScope, would be higher than the success rate with direct laryngoscopy. 3831 total intubation attempts were tracked in an observational study comparing first-pass success rate using a Macintosh or Miller-style laryngoscope with the GlideScope. Propensity scoring was then used to select 626 subjects matched between the two groups based on their morphologic traits. Comparing the GlideScope and direct laryngoscopy groups suggested that intubation would be more difficult in the GlideScope group based on the Mallampati class, cervical range of motion, mouth opening, dentition, weight, and past intubation history. Thus, a propensity score based on these factors was used to balance the groups into two 313 patient cohorts. Direct laryngoscopy was successful in 80.8% on the first-pass intubation attempt, while the GlideScope was successful in 93.6% (p <0.001; risk difference of 0.128 with a 95% CI of 0.0771 – 0.181). A greater first-attempt success rate was found when using the GlideScope versus direct laryngoscopy. In addition, the GlideScope was found to be 99% successful for intubation after initial failure of direct laryngoscopy, helping to reduce the incidence of failed intubation.
- 5 November 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 101
Open AccessGlideScope Use improves intubation success rates: an observational study using propensity score matching
Rigid video laryngoscopes are popular alternatives to direct laryngoscopy for intubation, but further large scale prospective studies comparing these devices to direct laryngoscopy in routine anesthesiology practice are needed. We hypothesized that the first pass success rate with one particular video laryngoscope, the GlideScope, would be higher than the success rate with direct laryngoscopy. 3831 total intubation attempts were tracked in an observational study comparing first-pass success rate using a Macintosh or Miller-style laryngoscope with the GlideScope. Propensity scoring was then used to select 626 subjects matched between the two groups based on their morphologic traits. Comparing the GlideScope and direct laryngoscopy groups suggested that intubation would be more difficult in the GlideScope group based on the Mallampati class, cervical range of motion, mouth opening, dentition, weight, and past intubation history. Thus, a propensity score based on these factors was used to balance the groups into two 313 patient cohorts. Direct laryngoscopy was successful in 80.8% on the first-pass intubation attempt, while the GlideScope was successful in 93.6% (p <0.001; risk difference of 0.128 with a 95% CI of 0.0771 – 0.181). A greater first-attempt success rate was found when using the GlideScope versus direct laryngoscopy. In addition, the GlideScope was found to be 99% successful for intubation after initial failure of direct laryngoscopy, helping to reduce the incidence of failed intubation.