Chaoli Xu
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Chaoli Xu has a total of 42 co-authors. Here are the top co-authors by number of shared publications:
- Bin Yang
Central hospital of eastern theater command, Nanjing, China
3 shared publications - Changjun Wu
The First Affiliated Hospital of Harbin Medical University, Harbin, China
2 shared publications - Chong Wu
Fifth Medical Center of Chinese PLA General Hospital, Beijing, China
2 shared publications - Christoph Friedrich Dietrich
University Hospital Frankfurt, Johann-Wolfgang-Goethe University Frankfurt on the Main, Frankfurt am Main, Germany
2 shared publications - Fei Wang
XU Chang Central Hospital, Xuchang, China
2 shared publications - Guo-Yan Liu
The First Affiliated Hospital of USTC, Hefei, China
2 shared publications
Latest Publications
- Open Access
- 6 September 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107550
Biohybrid Chlorella-HSA with Self-Oxygenation and Dual-Modal activation for synergistic Photo-Sonodynamic immunotherapy
- 6 September 2025
- Published by Elsevier in Ultrasonics Sonochemistry
- Vol. 121, 107550
Open AccessBiohybrid Chlorella-HSA with Self-Oxygenation and Dual-Modal activation for synergistic Photo-Sonodynamic immunotherapy
- Open Access
- 13 June 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-2
Correction: Comparing Sonazoid contrast-enhanced ultrasound to contrast-enhanced CT and MRI for differentially diagnosing renal lesions: a prospective multicenter study
- 13 June 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-2
Open AccessCorrection: Comparing Sonazoid contrast-enhanced ultrasound to contrast-enhanced CT and MRI for differentially diagnosing renal lesions: a prospective multicenter study
- 8 May 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-7
Comparing Sonazoid contrast-enhanced ultrasound to contrast-enhanced CT and MRI for differentially diagnosing renal lesions: a prospective multicenter study
Purpose To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ–CEUS) by comparing with contrast-enhanced computed tomography (CE–CT) and contrast-enhanced magnetic resonance imaging (CE–MRI) for differentiating benign and malignant renal masses. Materials and methods 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ–CEUS, CE–CT or CE–MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar’s test. Results In the head-to-head comparison, SNZ–CEUS and CE–MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ–CEUS and CE–CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ–CEUS had relatively lower than specificity than CE–CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE–MRI demonstrated higher specificity than SNZ–CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. Conclusions SNZ–CEUS, CE–CT, and CE–MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ–CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.
- 8 May 2024
- Published by Springer Nature in World Journal of Urology
- Vol. 42 (1) , 1-7
Comparing Sonazoid contrast-enhanced ultrasound to contrast-enhanced CT and MRI for differentially diagnosing renal lesions: a prospective multicenter study
Purpose To evaluate the diagnostic performance of contrast-enhanced (CE) ultrasound using Sonazoid (SNZ–CEUS) by comparing with contrast-enhanced computed tomography (CE–CT) and contrast-enhanced magnetic resonance imaging (CE–MRI) for differentiating benign and malignant renal masses. Materials and methods 306 consecutive patients (from 7 centers) with renal masses (40 benign tumors, 266 malignant tumors) diagnosed by both SNZ–CEUS, CE–CT or CE–MRI were enrolled between September 2020 and February 2021. The examinations were performed within 7 days, but the sequence was not fixed. Histologic results were available for 301 of 306 (98.37%) lesions and 5 lesions were considered benign after at least 2 year follow-up without change in size and image characteristics. The diagnostic performances were evaluated by sensitivity, specificity, positive predictive value, negative predictive value, and compared by McNemar’s test. Results In the head-to-head comparison, SNZ–CEUS and CE–MRI had comparable sensitivity (95.60 vs. 94.51%, P = 0.997), specificity (65.22 vs. 73.91%, P = 0.752), positive predictive value (91.58 vs. 93.48%) and negative predictive value (78.95 vs. 77.27%); SNZ–CEUS and CE–CT showed similar sensitivity (97.31 vs. 96.24%, P = 0.724); however, SNZ–CEUS had relatively lower than specificity than CE–CT (59.09 vs. 68.18%, P = 0.683). For nodules > 4 cm, CE–MRI demonstrated higher specificity than SNZ–CEUS (90.91 vs. 72.73%, P = 0.617) without compromise the sensitivity. Conclusions SNZ–CEUS, CE–CT, and CE–MRI demonstrate desirable and comparable sensitivity for the differentiation of renal mass. However, the specificity of all three imaging modalities is not satisfactory. SNZ–CEUS may be a suitable alternative modality for patients with renal dysfunction and those allergic to gadolinium or iodine-based agents.
- 8 October 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 38 (4) , 291-296
Subchorionic Hematoma Volume Measured by Virtual Organ Computer-Aided Analysis in the Prediction of First-Trimester Pregnancy Outcome
This study aimed to assess the association of subchorionic hematoma (SCH) size measured by virtual organ computer-aided analysis (VOCAL) with the first-trimester pregnancy outcome. A total of 139 first-trimester pregnancies from 6 to 12 weeks of gestational age with SCH were included. The circumference, area, and volume of the SCH (Cs, As, and 3DVs) and gestational sac (Cg, Ag, and 3DVg) were automatically calculated by VOCAL. Interobserver agreement was assessed with the intraclass correlation coefficient and Bland-Altman plot. Odds ratios for the clinical and ultrasound characteristics of adverse pregnancy outcomes were estimated by univariate or multivariable logistic regression. There was high interobserver agreement in VOCAL measurements of the SCH and gestational sac (intraclass correlation coefficients, >0.900). By univariate regression analysis, women with adverse pregnancy outcomes were more likely to have vaginal bleeding, a larger As and 3DVs, and higher Cs/Cg, As/Ag, and 3DVs/3DVg ratios (all P < 0.05). In the multivariable regression analysis, a higher 3DVs/3DVg ratio of SCH (odds ratio, 1.034; 95% confidence interval [CI], 1.015–1.053; P = 0.000) and vaginal heavy bleeding had a significant positive relationship with the risk of adverse pregnancy outcomes (odds ratio, 7.846; 95% CI, 1.104–55.737; P = 0.039) remained associated with an increased risk of adverse pregnancy outcomes. With 11.87% as the cutoff, the receiver operating characteristic curve yielded a good predictive performance (area under the curve, 0.713) and high sensitivity (91.18%). The measurements of SCH by VOCAL provide high reliability for estimating the total hematoma burden in first-trimester pregnant patients. A greater volume proportion (3DVs/3DVg) of SCH worsens the pregnancy outcome, and a greater risk of adverse pregnancy outcome also associated with the severity of vaginal bleeding.
- 8 October 2022
- Published by Wolters Kluwer Health in Ultrasound Quarterly
- Vol. 38 (4) , 291-296
Subchorionic Hematoma Volume Measured by Virtual Organ Computer-Aided Analysis in the Prediction of First-Trimester Pregnancy Outcome
This study aimed to assess the association of subchorionic hematoma (SCH) size measured by virtual organ computer-aided analysis (VOCAL) with the first-trimester pregnancy outcome. A total of 139 first-trimester pregnancies from 6 to 12 weeks of gestational age with SCH were included. The circumference, area, and volume of the SCH (Cs, As, and 3DVs) and gestational sac (Cg, Ag, and 3DVg) were automatically calculated by VOCAL. Interobserver agreement was assessed with the intraclass correlation coefficient and Bland-Altman plot. Odds ratios for the clinical and ultrasound characteristics of adverse pregnancy outcomes were estimated by univariate or multivariable logistic regression. There was high interobserver agreement in VOCAL measurements of the SCH and gestational sac (intraclass correlation coefficients, >0.900). By univariate regression analysis, women with adverse pregnancy outcomes were more likely to have vaginal bleeding, a larger As and 3DVs, and higher Cs/Cg, As/Ag, and 3DVs/3DVg ratios (all P < 0.05). In the multivariable regression analysis, a higher 3DVs/3DVg ratio of SCH (odds ratio, 1.034; 95% confidence interval [CI], 1.015–1.053; P = 0.000) and vaginal heavy bleeding had a significant positive relationship with the risk of adverse pregnancy outcomes (odds ratio, 7.846; 95% CI, 1.104–55.737; P = 0.039) remained associated with an increased risk of adverse pregnancy outcomes. With 11.87% as the cutoff, the receiver operating characteristic curve yielded a good predictive performance (area under the curve, 0.713) and high sensitivity (91.18%). The measurements of SCH by VOCAL provide high reliability for estimating the total hematoma burden in first-trimester pregnant patients. A greater volume proportion (3DVs/3DVg) of SCH worsens the pregnancy outcome, and a greater risk of adverse pregnancy outcome also associated with the severity of vaginal bleeding.
- Open Access
- 20 April 2022
- Published by Springer Nature in Research Square
Correlation of Automated Breast Volume Scanner Imaging and the Difference of Molecular Subtypes Between Core Needle Biopsy and Surgical Specimens
Background: Core needle biopsy (CNB) and automated breast volume scanner (ABVS) play crucial roles in diagnosing breast cancer. However, the molecular subtype of breast cancer in CNB and surgery is a paradox at times. Analyzing the correlation between ABVS and the difference of molecular subtypes between CNB and surgery specimens has not been reported. The purpose of this study is to identify the characteristics of ABVS imaging that affect the discrepancy of molecular subtypes between CNB and surgical specimens in breast cancer patients.Methods: Eighty-two breast cancer patients (83 lesions) who underwent ABVS examinations were enrolled at Jinling Hospital between November 2014 to October 2020. The molecular subtypes (luminal A, luminal B (HER-2 positive), luminal B (HER-2 negative), HER-2 overexpression, and triple-negative subtypes) and the discrepancy rate of the specimens via CNB and surgery were determined. The clinicopathological and ABVS imaging features were compared between the discrepancy group (molecular subtypes were different between CNB and surgery specimens) and the consistency group (molecular subtypes were concordant between CNB and surgery specimens). Receiver operating characteristic (ROC) curves were plotted for the diagnostic performance of the significant features. Results: Of the 83 lesions, a concordance rate of 73.5% (κ=0.64) was shown between the CNB specimens and the surgical specimens for molecular subtypes. The presence of clear boundary, irregular shape, well-defined margin, and no retraction phenomenon on ABVS were independently associated with discrepancy in molecular subtypes (all P < 0.05). The area under the curve (AUC) for the combination of these four features on ABVS was 0.9 (95% CI:0.8-0.9), yielding a sensitivity and specificity of 100% and 41%, respectively.Conclusions: ABVS is feasible with excellent sensitivity in determining the discrepancy of molecular subtypes between specimens via CNB and surgery. Multipoint puncture during CNB should be advocated for the lesions with the presence of clear boundary, irregular shape, well-defined margin, and lack of retraction phenomenon, thus leading to avoidance of discrepancy in molecular subtypes in clinical diagnosis and treatment processes in breast cancer patients.
- 20 April 2022
- Published by Springer Nature in Research Square
Open AccessCorrelation of Automated Breast Volume Scanner Imaging and the Difference of Molecular Subtypes Between Core Needle Biopsy and Surgical Specimens
Background: Core needle biopsy (CNB) and automated breast volume scanner (ABVS) play crucial roles in diagnosing breast cancer. However, the molecular subtype of breast cancer in CNB and surgery is a paradox at times. Analyzing the correlation between ABVS and the difference of molecular subtypes between CNB and surgery specimens has not been reported. The purpose of this study is to identify the characteristics of ABVS imaging that affect the discrepancy of molecular subtypes between CNB and surgical specimens in breast cancer patients.Methods: Eighty-two breast cancer patients (83 lesions) who underwent ABVS examinations were enrolled at Jinling Hospital between November 2014 to October 2020. The molecular subtypes (luminal A, luminal B (HER-2 positive), luminal B (HER-2 negative), HER-2 overexpression, and triple-negative subtypes) and the discrepancy rate of the specimens via CNB and surgery were determined. The clinicopathological and ABVS imaging features were compared between the discrepancy group (molecular subtypes were different between CNB and surgery specimens) and the consistency group (molecular subtypes were concordant between CNB and surgery specimens). Receiver operating characteristic (ROC) curves were plotted for the diagnostic performance of the significant features. Results: Of the 83 lesions, a concordance rate of 73.5% (κ=0.64) was shown between the CNB specimens and the surgical specimens for molecular subtypes. The presence of clear boundary, irregular shape, well-defined margin, and no retraction phenomenon on ABVS were independently associated with discrepancy in molecular subtypes (all P < 0.05). The area under the curve (AUC) for the combination of these four features on ABVS was 0.9 (95% CI:0.8-0.9), yielding a sensitivity and specificity of 100% and 41%, respectively.Conclusions: ABVS is feasible with excellent sensitivity in determining the discrepancy of molecular subtypes between specimens via CNB and surgery. Multipoint puncture during CNB should be advocated for the lesions with the presence of clear boundary, irregular shape, well-defined margin, and lack of retraction phenomenon, thus leading to avoidance of discrepancy in molecular subtypes in clinical diagnosis and treatment processes in breast cancer patients.
- Open Access
- 3 November 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 798
Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast
Automated breast volume scanner (ABVS) and US elastography (UE) have been useful for the differentiation of benign and malignant lesions. However, combining these two methods applied in diagnosis of breast lesions has not yet been reported. The aim of this study is to analyze the inter-examiner reliability of ABVS and UE, and compare diagnostic performance among ABVS, UE, and the combination of these two methods. Forty-one patients (forty-six lesions) underwent both ABVS and UE examinations. ABVS images were acquired by medial and lateral scans for each breast and classified a BI-RADS category based on the distribution, size, shape, echogenicity and microcalcification of the lesions. UE images were assigned an elasticity score according to the distribution of strain induced by light compression. Kappa statistics was used to examine the reproducibility between examiners with ABVS and UE, and the concordance between pathology and ABVS, UE, and the combination of these two methods. χ 2 test was used to compare diagnostic performance among these three methods. Two examiners blinded to the patients’ history evaluated the results of breast imaging independently. Inter-examiner reliability with ABVS (κ = 0.62, 95% confidence interval (CI): 0.44-0.80) and UE (κ = 0.65, 95% CI: 0.48-0.82) was substantial. With respect to the pathology results, the inter-rater coefficient of concordance was κ = 0.81 (95% CI: 0.64-0.98) for ABVS, κ = 0.77 (95% CI: 0.58-0.96) for UE, and κ = 0.90 (95% CI: 0.77-1.00) for combination of ABVS and UE. Examiner variability was reduced from UE to ABVS, and to the combination of ABVS with UE. The diagnostic accuracy, sensitivity, and specificity for the combination of ABVS and UE were 95.7% (95%CI: 84.0-99.2), 100% (95% CI: 85.9-100), and 87.5% (95% CI: 60.4-97.8), respectively. When comparing, the diagnostic performance of ABVS combined with UE was better than, or at least equal to, that of ABVS (accuracy 91.3% (95% CI: 78.3-97.2), sensitivity 100% (95% CI: 85.0-1.00), specificity 77.8% (95% CI: 51.9-92.6)) or UE (accuracy 89.1% (95% CI: 75.6-95.9), sensitivity 96.4% (95% CI: 79.8-99.8), specificity 77.8% (95% CI: 51.9-92.6)) alone, though the improvement was no statistically significance. Both ABVS and UE demonstrated substantial inter-examiner reliability. With high diagnostic performance for differentiation of benign and malignant lesions in the breast, the combination of ABVS and UE are useful to improve the diagnostic accuracy and specificity.
- 3 November 2014
- Published by Springer Nature in BMC Cancer
- Vol. 14 (1) , 798
Open AccessCombined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast
Automated breast volume scanner (ABVS) and US elastography (UE) have been useful for the differentiation of benign and malignant lesions. However, combining these two methods applied in diagnosis of breast lesions has not yet been reported. The aim of this study is to analyze the inter-examiner reliability of ABVS and UE, and compare diagnostic performance among ABVS, UE, and the combination of these two methods. Forty-one patients (forty-six lesions) underwent both ABVS and UE examinations. ABVS images were acquired by medial and lateral scans for each breast and classified a BI-RADS category based on the distribution, size, shape, echogenicity and microcalcification of the lesions. UE images were assigned an elasticity score according to the distribution of strain induced by light compression. Kappa statistics was used to examine the reproducibility between examiners with ABVS and UE, and the concordance between pathology and ABVS, UE, and the combination of these two methods. χ 2 test was used to compare diagnostic performance among these three methods. Two examiners blinded to the patients’ history evaluated the results of breast imaging independently. Inter-examiner reliability with ABVS (κ = 0.62, 95% confidence interval (CI): 0.44-0.80) and UE (κ = 0.65, 95% CI: 0.48-0.82) was substantial. With respect to the pathology results, the inter-rater coefficient of concordance was κ = 0.81 (95% CI: 0.64-0.98) for ABVS, κ = 0.77 (95% CI: 0.58-0.96) for UE, and κ = 0.90 (95% CI: 0.77-1.00) for combination of ABVS and UE. Examiner variability was reduced from UE to ABVS, and to the combination of ABVS with UE. The diagnostic accuracy, sensitivity, and specificity for the combination of ABVS and UE were 95.7% (95%CI: 84.0-99.2), 100% (95% CI: 85.9-100), and 87.5% (95% CI: 60.4-97.8), respectively. When comparing, the diagnostic performance of ABVS combined with UE was better than, or at least equal to, that of ABVS (accuracy 91.3% (95% CI: 78.3-97.2), sensitivity 100% (95% CI: 85.0-1.00), specificity 77.8% (95% CI: 51.9-92.6)) or UE (accuracy 89.1% (95% CI: 75.6-95.9), sensitivity 96.4% (95% CI: 79.8-99.8), specificity 77.8% (95% CI: 51.9-92.6)) alone, though the improvement was no statistically significance. Both ABVS and UE demonstrated substantial inter-examiner reliability. With high diagnostic performance for differentiation of benign and malignant lesions in the breast, the combination of ABVS and UE are useful to improve the diagnostic accuracy and specificity.