BYBin Yang

Bin Yang

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Bin Yang has a total of 55 co-authors. Here are the top co-authors by number of shared publications:

  • Jing Wu

    Department of Ultrasound, Affiliated Hospital of Nantong University (The First People’s Hospital of Yancheng), Yancheng, P.R China

    4 shared publications
  • Shuping Wei

    Department of Ultrasound, Jinling Clinical Medical College of Nanjing Medical University, Nanjing, China

    3 shared publications
  • Xiao Zhi Zheng

    Department of Ultrasound, Affiliated Hospital of Nantong University (The First People’s Hospital of Yancheng), Yancheng, P.R China

    3 shared publications
  • Chaoli Xu

    Department of Ultrasound Diagnostic Jinling Hospital School of Medicine Nanjing University Nanjing 210002 P. R. China

    2 shared publications
  • Ninghua Fu

    Department of Ultrasound, Jinling Hospital, Medical School of Nanjing University, Nanjing, Jiangsu Province, China

    2 shared publications
  • Xiao-Zhi Zheng

    Department of Ultrasound, Jinling Hospital, Nanjing University School of Medicine , Nanjing City, Jiangsu Province , P.R.China

    2 shared publications

Latest Publications

  • Open Access

    High-frequency repetitive transcranial magnetic stimulation improves functional recovery by inhibiting neurotoxic polarization of astrocytes in ischemic rats

    by Ye Hong, Qian Liu, Mengna Peng, Maosheng Bai, Juanji Li, Rui Sun, Hongquan Guo, Pengfei Xu, Yi Xie, Yunzi Li, et al.

    Background: Repetitive transcranial magnetic stimulation (rTMS) is a noninvasive treatment for ischemic stroke. Astrocytes regulation has been suggested as one mechanism for rTMS effectiveness. But how rTMS regulates astrocytes remains largely undetermined. There were neurotoxic and neuroprotective phenotypes of astrocytes (also denoted as classically and alternatively activated astrocytes or A1 and A2 astrocytes) pertaining to pro- or anti-inflammatory gene expression. Pro-inflammatory or neurotoxic polarized astrocytes were induced during cerebral ischemic stroke. The present study aimed to investigate the effects of rTMS on astrocytic polarization during cerebral ischemic/reperfusion injury. Methods: Three rTMS protocols were applied to primary astrocytes under normal and oxygen-glucose deprivation/reoxygenation (OGD/R) conditions. Cell survival, proliferation, and phenotypic changes were assessed after 2-day treatment. Astrocytes culture medium (ACM) from control, OGD/R, and OGD/R + rTMS groups were mixed with neuronal medium to culture neurons for 48 h and 7 days, in order to explore the influence on neuronal survival and synaptic plasticity. In vivo, rats were subjected to middle cerebral artery occlusion (MCAO), and received posterior orbital intravenous injection of ACM collected from different groups at reperfusion, and at 3 days post reperfusion. The apoptosis in the ischemic penumbra, infarct volumes, and the modified Neurological Severity Score (mNSS) were evaluated at 1 week after reperfusion, and cognitive functions were evaluated using the Morris Water Maze (MWM) tests. Finally, the 10 Hz rTMS was directly applied to MCAO rats to verify the rTMS effects on astrocytic polarization. Results: Among these three frequencies, the 10 Hz protocol exerted the greatest potential to modulate astrocytic polarization after OGD/R injury. Classically activated and A1 markers were significantly inhibited by rTMS treatment. In OGD/R model, the concentration of pro-inflammatory mediator TNF-α decreased from 57.7 to 23.0 рg/mL, while anti-inflammatory mediator IL-10 increased from 99.0 to 555.1 рg/mL in the ACM after rTMS treatment. The ACM collected from rTMS-treated astrocytes significantly alleviated neuronal apoptosis induced by OGD/R injury, and promoted neuronal plasticity. In MCAO rat model, the ACM collected from rTMS treatment decreased neuronal apoptosis and infarct volumes, and improved cognitive functions. The neurotoxic astrocytes were simultaneously inhibited after rTMS treatment. Conclusion: Inhibition of neurotoxic astrocytic polarization is a potential mechanism for the effectiveness of high-frequency rTMS in cerebral ischemic stroke.


  • Flexible MoS2‐Embedded Human Serum Albumin Hollow Nanocapsules with Long Circulation Times and High Targeting Ability for Efficient Tumor Ablation

    by Chaoli Xu, Zhaogang Teng, Yunlei Zhang, Lihui Yuwen, Qi Zhang, Xiaodan Su, Meng Dang, Ying Tian, Jun Tao, Lei Bao, et al.

    Herein, MoS2‐embedded human serum albumin hollow nanocapsules (denoted MoS2/HSA) are successfully prepared via a hard‐core‐assisted layer‐by‐layer coating approach. The hollow MoS2/HSA nanocapsules possess an uniform size (280 nm), a larger hollow cavity, a low Young's modulus (222 ± 20 MPa), excellent photothermal conversion ability, and a high drug loading capacity for doxorubicin (27 wt%). The flexible hollow MoS2/HSA nanocapsules exhibit significantly enhanced cellular uptake efficiency against breast cancer cells duo to their flexible property and targeting ability of HSA. In vivo experiments show that the flexible MoS2/HSA could reduce phagocytosis and effectively improve blood persistence and tumor accumulation. In vitro and in vivo experiments have demonstrated that the flexible MoS2/HSA based nanoplatforms effectively ablate breast cancer cells via synergistic photothermal and chemical therapy.


  • Open Access

    SHP2 overexpression enhances the invasion and metastasis of ovarian cancer in vitro and in vivo

    by Zhongqian Hu, Jia Li, Qi Gao, Shuping Wei, Bin Yang

    Purpose: SHP2 has roles in a variety of signal transduction pathways and in many important cellular processes, including proliferation, differentiation, movement regulation, and apoptosis. In addition, SHP2 expression is closely associated with multiple types of malignancies. In this study, we examined the role of SHP2 in epithelial ovarian cancer. Patients and methods: SHP2 expression in cancer and normal ovarian tissue specimens was evaluated by immunohistochemical staining and Western blot analyses. The correlation between the SHP2 expression level and clinicopathological features was analyzed. The role of SHP2 in epithelial ovarian cancer was evaluated by assessing SHP2 expression patterns in vitro and in vivo, and activation of the PI3K/AKT pathway was examined. Results: SHP2 is expressed at higher levels in ovarian cancer tissues than in normal ovarian tissues and in an ovarian cancer cell line than in a normal ovarian cell line. On the basis of these findings, SHP2 is overexpressed in ovarian cancer both in vitro and in vivo. In addition, SHP2 overexpression is associated with tumor stage and differentiation, enhanced cell proliferation and invasion, and tumorigenesis and metastasis. Conclusion: SHP2 overexpression enhances ovarian tumor proliferation and invasion by activating the PI3K-AKT axis, indicating that SHP2 potentially plays a direct role in the pathogenesis of ovarian epithelial cell cancer. These novel findings provide key insights that are applicable to basic cancer research and to the prevention and treatment of cancer.


  • Short Hairpin RNA Knockdown of Connective Tissue Growth Factor by Ultrasound-Targeted Microbubble Destruction Improves Renal Fibrosis

    by Shuping Wei, Chaoli Xu, Joshua J. Rychak, Alice Luong, Yu Sun, Zhijian Yang, Mingxia Li, Chunrui Liu, Ninghua Fu, Bin Yang


  • Open Access

    Combined use of the automated breast volume scanner and the US elastography for the differentiation of benign from malignant lesions of the breast

    by Chaoli Xu, Shuping Wei, Yingdong Xie, Xiaoxiang Guan, Ninghua Fu, Pengfei Huang, Bin Yang

    Automated breast volume scanner (ABVS) and US elastography (UE) have been useful for the differentiation of benign and malignant lesions. However, combining these two methods applied in diagnosis of breast lesions has not yet been reported. The aim of this study is to analyze the inter-examiner reliability of ABVS and UE, and compare diagnostic performance among ABVS, UE, and the combination of these two methods. Forty-one patients (forty-six lesions) underwent both ABVS and UE examinations. ABVS images were acquired by medial and lateral scans for each breast and classified a BI-RADS category based on the distribution, size, shape, echogenicity and microcalcification of the lesions. UE images were assigned an elasticity score according to the distribution of strain induced by light compression. Kappa statistics was used to examine the reproducibility between examiners with ABVS and UE, and the concordance between pathology and ABVS, UE, and the combination of these two methods. χ 2 test was used to compare diagnostic performance among these three methods. Two examiners blinded to the patients’ history evaluated the results of breast imaging independently. Inter-examiner reliability with ABVS (κ = 0.62, 95% confidence interval (CI): 0.44-0.80) and UE (κ = 0.65, 95% CI: 0.48-0.82) was substantial. With respect to the pathology results, the inter-rater coefficient of concordance was κ = 0.81 (95% CI: 0.64-0.98) for ABVS, κ = 0.77 (95% CI: 0.58-0.96) for UE, and κ = 0.90 (95% CI: 0.77-1.00) for combination of ABVS and UE. Examiner variability was reduced from UE to ABVS, and to the combination of ABVS with UE. The diagnostic accuracy, sensitivity, and specificity for the combination of ABVS and UE were 95.7% (95%CI: 84.0-99.2), 100% (95% CI: 85.9-100), and 87.5% (95% CI: 60.4-97.8), respectively. When comparing, the diagnostic performance of ABVS combined with UE was better than, or at least equal to, that of ABVS (accuracy 91.3% (95% CI: 78.3-97.2), sensitivity 100% (95% CI: 85.0-1.00), specificity 77.8% (95% CI: 51.9-92.6)) or UE (accuracy 89.1% (95% CI: 75.6-95.9), sensitivity 96.4% (95% CI: 79.8-99.8), specificity 77.8% (95% CI: 51.9-92.6)) alone, though the improvement was no statistically significance. Both ABVS and UE demonstrated substantial inter-examiner reliability. With high diagnostic performance for differentiation of benign and malignant lesions in the breast, the combination of ABVS and UE are useful to improve the diagnostic accuracy and specificity.


  • Open Access

    Comparison of the Efficacy of Conventional Echocardiographic Parameters in the Diagnosis of Significant Coronary Artery Stenosis

    by Xiao Zhi Zheng, Bin Yang, Jing Wu

    Background: For diagnosis of significant coronary artery stenosis, the most accurate parameter among the conventional echocardiographic parameters remains unknown. Objectives: To assess the diagnostic efficacy of conventional echocardiographic parameters in the diagnosis of significant coronary artery stenosis and their correlation with the percentage of stenosis considering conventional coronary angiography as gold standard. Patients and Methods: Seventy eight individuals were included in the study. The three echocardiographic parameters including the coronary sinus flow [flow (mL/minute)], the global left ventricular perfusion by dividing the coronary sinus flow by left ventricular mass [flow/LVM (mL/minute)] and the difference between the left ventricular mass at end diastole and peak systole using area-length calculation methods [LV (d-s) mass A-L] were assessed using receiver operating characteristic (ROC) analysis for their accuracy to distinguish between normal subjects and patients with significant (> 50%) coronary artery disease (CAD). Results: Flow (mL/minute), flow/LVM (mL/minuteg) and LV (d-s) mass A-L all correlated significantly with the percentage of stenosis (r = -0.64, P < 0.001; r = -0.47, P < 0.001; r = -0.56, P < 0.001, respectively). With the use of the percentage of stenosis > 50% as the criteria to distinguish patients with or without CAD, the areas under the ROC curve for flow (mL/minute) were 0.75, while they were 0.57 for flow/LVM (mL/minuteg) and 0.59 for LV (d-s) mass A-L. The percentage of stenosis > 70% was best detected by coronary sinus flow < 198 mL/minute (sensitivity, 81.35%; specificity, 70.37%; positive predictive value, 63.63%; negative predictive value, 86.36% and accuracy, 75%; P < 0.001). Conclusions: The coronary sinus flow per minute is the most accurate parameter among the three echocardiographic parameters mentioned above for the assessment of significant stenosis of the coronary artery. Keywords: Coronary Sinus Flow; Myocardial Perfusion; Left Ventricular Mass; Coronary Artery Stenosis

  • Open Access

    Preliminary Study on the Kidney Elasticity Quantification in Patients With Chronic Kidney Disease Using Virtual Touch Tissue Quantification

    by Xiao Zhi Zheng, Bin Yang, Ning Hua Fu

    Background: Virtual touch tissue quantification (VTTQ) provides numerical measurements (shear wave velocity (SWV) values) of tissue stiffness. Objectives: The purpose of this study was to describe the SWV values of the kidney by VTTQ and to examine the clinical usefulness of this procedure in the evaluation of elasticity changes in the kidneys of patients with chronic kidney disease (CKD). Patients and Methods: Sixty-five patients with CKD and seventy healthy participants were included in this study. A total of 270 kidneys were examined by VTTQ. The kidney elasticity was expressed as shear wave velocity. The SWV values, blood serum creatinine (Scr)/BUN and pathological findings were analyzed and compared between patients with CKD and healthy participants. Results: In patients with CKD and healthy participants, the SWV values both gradually decreased from the renal cortex to the medulla and renal sinus The SWV value of the renal cortex in patients with CKD was less than that of healthy participants (P < 0.05), and the SWV value of the renal cortex in patients with renal insufficiency was significantly less than in those with normal renal function (2.46 ± 0.15 vs. 3.45 ± 0.26 m/s, P < 0.05). The best cutoff value for predicting renal insufficiency (Scr > 1.24 mg/dL or/and BUN > 21 mg/DL) was a SWV value of the renal cortex of less than 1.92 m/s with a sensitivity of 84.4% (95% CI: 67.2-94.7%) and a specificity of 96.8% (95% CI: 83.3-99.9%) (P < 0.001). Conclusion: VTTQ can sensitively detect the elasticity changes in patients with CKD, and it can effectively predict renal insufficiency. This technology provides a valuable tool for the assessment of CKD. Keywords: Ultrasonography; Virtual Touch Tissue Quantitative; Chronic Kidney Disease


  • Open Access

    A Comparison of the Performance of Myocardial Videodensitometry, Tissue Velocity Imaging and Tissue Tracking in Discrimination Between ST-Segment Elevation Ischemic Reperfusion Injury and Normal Reperfusion State After Non-Beating Cardiac Operation

    by Xiao Zhi Zheng, Bin Yang, Jing Wu

    Background: The timely diagnosis of presence or absence of reperfusion injury after cardiac operation is critical for the patient’s outcome. Whether transesophageal echocardiography (TEE) acquisition of regional grayscale intensity (TI), velocity, and displacement (D) after cardiac operation can discriminate between patients with ST-segment elevation ischemic reperfusion injury (STEIRI) and normal reperfusion state remains unknown. Objectives: In this study, we investigated whether these parameters can effectively reflect the situation of ST-segment elevation ischemic reperfusion injury (STEIRI) in patients after cardiac operation and which has a higher performance of discrimination between patients with and without STEIRI. Patients and Methods: The maximal and minimal grayscale intensity in the cardiac cycle [TI (max), TI (min)], the difference of TI (max) and TI (min) [TI (max-min)], the cyclic variation index of TI [TI (CVI)], the systolic velocity (Vs), the early diastolic velocity (Ve), the late diastolic velocity (Va) and the peak displacement in the cardiac cycle (D) at the lateral side of the mitral annulus were measured and compared between patients with and without STEIRI. The performance of these parameters in discriminating between patients with and without STEIRI was analyzed. Results: Compared with the patients without STEIRI, the patients with STEIRI had significantly smaller TI (max-min), TI (CVI), Vs, Ve, Va and D (P<0.05). With the use of these parameters as the criteria to distinguish patients with STEIRI from patients without STEIRI, the areas under the receiver operating characteristic curve were 0.86 for TI (max-min), 0.99 for TI (CVI), 0.89 for Vs, 0.71 for Ve, 0.85 for Va and 0.82 for D. For the best cut-off value of TI (CVI) of less than 34.45%, the sensitivity, specificity and accuracy for the prediction of patients with STEIRI were 94.74%, 97.05%, and 96.22%, respectively. Conclusion: The myocardial grayscale intensity, velocity and displacement can effectively reflect the situation of STEIRI in patients after cardiac operation, and TI (CVI) has a higher performance in discriminating between patients with and without STEIRI. Keywords: Grayscale Intensity; Velocity; Displacement; Cardiac Operation


  • Feasibility of a New Image Processing (4D Auto LVQ) to Assessing Right Ventricular Function in Patients with Chronic Obstructive Pulmonary Disease

    by Xiao-Zhi Zheng, Bin Yang, Jing Wu

    A new single-beat three-dimensional (3D) real time echocardiographic semi-automatic images processing (4D Auto LVQ) allows accurate assessment of left ventricular function, but whether it is suitable for the evaluation of right ventricular function remains unknown. To evaluate the feasibility of this procedure for assessing right ventricular volumes and function, right ventricular end-diastolic volumes (RVEDV), end-systolic volumes (RVESV) and ejection fraction (RVEF), stroke volumes (SV) and cardiac output (CO) were computed in 49 patients with chronic obstructive pulmonary disease (COPD) using 4D Auto LVQ. The myocardial performance index (MPI) was obtained by Doppler tissue imaging. The RV function parameters were compared with MPI by linear correlation analysis. A comparison of the performance of these RV function parameters in discrimination between MPI at a value of >0.45 or not was done. Compared with normal subjects, patients with COPD had significantly greater RVEDV, RVESV, MPI and significantly lower RVEF. Significant correlations were found between RVEF and MPI (r = –0.67, p < 0.001). The areas under the receiver operating characteristic curve for RVEF in discrimination between MPI at a value of >0.45 or not were 0.72, while they were 0.55 for SV and 0.57 for CO, respectively. The overall sensitivity, specificity and accuracy for RVEF analysis in predicting a >0.45 MPI in patients with COPD was 78.57%, 66.67% and 73.46%, respectively. These data suggest that 4D Auto LVQ is a feasible method for right ventricular volumes and function quantification in patients with COPD. Further studies are needed to improve the accuracy of the measurements.