KSKimberly A Sollis

Kimberly A Sollis

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Kimberly A Sollis has a total of 22 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Regulation of medical diagnostics and medical devices in the East African community partner states

    by Simon Peter Rugera, Ruth McNerney, Albert K Poon, Gladys Akimana, Rehema Forgen Mariki, Henry Kajumbula, Elizabeth Kamau, Servilien Mpawenimana, Said Yusuf Said, Anthony Toroitich, et al.

    Medical devices and in vitro diagnostic tests (IVD) are vital components of health delivery systems but access to these important tools is often limited in Africa. The regulation of health commodities by National Regulatory Authorities is intended to ensure their safety and quality whilst ensuring timely access to beneficial new products. Streamlining and harmonizing regulatory processes may reduce delays and unnecessary expense and improve access to new products. Whereas pharmaceutical products are widely regulated less attention has been placed on the regulation of other health products. A study was undertaken to assess regulation of medical diagnostics and medical devices across Partner States of the East African Community (EAC). Data was collected during October 2012 through desk based review of documents and field research, including face to face interviews with the assistance of a structured questionnaire with closed and open ended questions. Key areas addressed were (i) existence and role of National Regulatory Authorities; (ii) policy and legal framework for regulation; (iii) premarket control; (iv) marketing controls; (v) post-marketing control and vigilance; (vi) country capacity for regulation; (vii) country capacity for evaluation studies for IVD and (viii) priorities and capacity building for harmonization in EAC Partner States. Control of medical devices and IVDs in EAC Partner States is largely confined to national disease programmes such as tuberculosis, HIV and malaria. National Regulatory Authorities for pharmaceutical products do not have the capacity to regulate medical devices and in some countries laboratory based organisations are mandated to ensure quality of products used. Some activities to evaluate IVDs are performed in research laboratories but post market surveillance is rare. Training in key areas is considered essential to strengthening regulatory capacity for IVDs and other medical devices. Regulation of medical devices and in vitro diagnostics has been neglected in EAC Partner States. Regulation is weak across the region, and although the majority of States have a legal mandate to regulate medical devices there is limited capacity to do so. Streamlining regulation in the EAC is seen as a positive aspiration with diagnostic tests considered a priority area for harmonisation.


  • External quality assurance with dried tube specimens (DTS) for point-of-care syphilis and HIV tests: experience in an indigenous populations screening programme in the Brazilian Amazon

    by Adele Schwartz Benzaken, Maria Luiza Bazzo, Enrique Galban, Ione Conceição Pereira Pinto, Christiane Lourenço Nogueira, Lisléia Golfetto, Nina Schwartz Benzaken, Kimberly A Sollis, David Mabey, Rosanna W Peeling

    Objectives The availability of point-of-care (POC) tests for infectious diseases has revolutionised the provision of healthcare for remote rural populations without access to laboratories. However, quality assurance for POC tests has been largely overlooked. We have evaluated the use and stability of dry tube specimens (DTS) for External Quality Assurance (EQA) for HIV and syphilis screening in remote indigenous populations in the Amazon region of Brazil. Methods All healthcare workers (HCWs) participating in the community-screening were trained. We used HIV and syphilis DTS panels developed by the reference laboratory, containing samples with negative and positive results at different antibody concentrations, for both infections. DTS panels were distributed to HCWs in the communities for reconstitution and testing using POC HIV and syphilis tests. The results of testing were sent to the reference laboratory for marking and remedial action taken where necessary. Results In total 268 HCWs tested 1607 samples for syphilis and 1608 samples for HIV. Results from HCWs showed a concordance rate of 90% for syphilis and 93% for HIV (κ coefficients of 0.74 and 0.78, respectively) with reference laboratories. Most false negatives were in samples of very low antibody concentration. DTS syphilis specimens produced the expected results after storage at 2–8°C or at 18–24°C for up to 3 weeks. Conclusions The results show that POC tests for syphilis and HIV give valid results in environments where traditional tests do not work, but errors in the interpretation of POC test results were identified by the EQA programme using DTS. EQA using DTS can help to improve the quality of screening programmes using POC tests in remote regions.