Takuro Sanuki
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Takuro Sanuki has a total of 18 co-authors. Here are the top co-authors by number of shared publications:
Junichiro Kotani
Professor, Department of Anesthesiology, Osaka Dental University, Osaka, Japan
8 shared publicationsShingo Sugioka
6 shared publicationsHiroki Son
4 shared publicationsMasafumi Akatsuka
4 shared publicationsRumiko Uda
4 shared publicationsMotoko Hirokane
3 shared publications
Latest Publications
- Open Access
- 28 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 637
Significance of debriefing methods in simulation-based sedation training courses for medical safety improvement in Japan
Based on the American Society of Anesthesiologists’ Practice Guidelines for Sedation and Analgesia by Non-Anesthesiologists (ASA-SED), a sedation training course aimed at improving medical safety was developed by the Japanese Association for Medical Simulation in 2011. This study evaluated the effect of debriefing on participants’ perceptions of the essential points of the ASA-SED. A total of 38 novice doctors participated in the sedation training course during the research period. Of these doctors, 18 participated in the debriefing group, and 20 participated in non-debriefing group. Scoring of participants’ guideline perceptions was conducted using an evaluation sheet (nine items, 16 points) created based on the ASA-SED. The debriefing group showed a greater perception of the ASA-SED, as reflected in the significantly higher scores on the evaluation sheet (median, 16 points) than the control group (median, 13 points; p < 0.05). No significant differences were identified before or during sedation, but the difference after sedation was significant (p < 0.05). Debriefing after sedation training courses may contribute to better perception of the ASA-SED, and may lead to enhanced attitudes toward medical safety during sedation and analgesia.
- 28 October 2014
- Published by Springer Nature in SpringerPlus
- Vol. 3 (1) , 637
Open AccessSignificance of debriefing methods in simulation-based sedation training courses for medical safety improvement in Japan
Based on the American Society of Anesthesiologists’ Practice Guidelines for Sedation and Analgesia by Non-Anesthesiologists (ASA-SED), a sedation training course aimed at improving medical safety was developed by the Japanese Association for Medical Simulation in 2011. This study evaluated the effect of debriefing on participants’ perceptions of the essential points of the ASA-SED. A total of 38 novice doctors participated in the sedation training course during the research period. Of these doctors, 18 participated in the debriefing group, and 20 participated in non-debriefing group. Scoring of participants’ guideline perceptions was conducted using an evaluation sheet (nine items, 16 points) created based on the ASA-SED. The debriefing group showed a greater perception of the ASA-SED, as reflected in the significantly higher scores on the evaluation sheet (median, 16 points) than the control group (median, 13 points; p < 0.05). No significant differences were identified before or during sedation, but the difference after sedation was significant (p < 0.05). Debriefing after sedation training courses may contribute to better perception of the ASA-SED, and may lead to enhanced attitudes toward medical safety during sedation and analgesia.
- 1 January 2013
- Published by American Dental Society of Anesthesiology (ADSA) in Anesthesia Progress
- Vol. 60 (3) , 109-110
Thermosoftening of the Parker Flex-TipTM Tracheal Tube in Preparation for Nasotracheal Intubation
The Parker Flex-Tip tracheal tube (PFTT, Parker Medical, Highlands Ranch, Colo) has a soft, flexible, curved tip with double Murphy eyes. Previous studies have shown that the PFTT reduces the incidence of epistaxis during nasotracheal intubation and the incidence of postintubation nasal pain, as compared to conventional tracheal tubes. Although thermosoftening is a well-known and effective technique for reducing epistaxis during nasotracheal intubation with conventional tracheal tubes, we occasionally encounter difficulties with advancing the tube through the nasal passage when the PFTT is thermosoftened prior to nasotracheal intubation. Consequently, when using the PFTT for nasotracheal intubation, the procedure of thermosoftening should be avoided.
- 1 January 2013
- Published by American Dental Society of Anesthesiology (ADSA) in Anesthesia Progress
- Vol. 60 (3) , 109-110
Thermosoftening of the Parker Flex-TipTM Tracheal Tube in Preparation for Nasotracheal Intubation
The Parker Flex-Tip tracheal tube (PFTT, Parker Medical, Highlands Ranch, Colo) has a soft, flexible, curved tip with double Murphy eyes. Previous studies have shown that the PFTT reduces the incidence of epistaxis during nasotracheal intubation and the incidence of postintubation nasal pain, as compared to conventional tracheal tubes. Although thermosoftening is a well-known and effective technique for reducing epistaxis during nasotracheal intubation with conventional tracheal tubes, we occasionally encounter difficulties with advancing the tube through the nasal passage when the PFTT is thermosoftened prior to nasotracheal intubation. Consequently, when using the PFTT for nasotracheal intubation, the procedure of thermosoftening should be avoided.
- 1 August 2011
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 28 (8) , 597-599
The influence of head and neck position on ventilation with the i-gel airway in paralysed, anaesthetised patients
We hypothesised that head and neck position could affect the effectiveness of ventilation with the i-gel airway. To test this hypothesis, we investigated the influence of different head and neck positions on oropharyngeal sealing pressures and ventilation scores during ventilation with i-gel. A single, experienced supraglottic airway device user inserted the i-gel in 20 paralysed, anaesthetised patients who were scheduled for oral surgery. Oropharyngeal leak pressures and ventilation scores were measured with the head and neck in the neutral position, flexed, extended or rotated to the right. Ventilation was scored from 0 to 3 based on three criteria (no leakage with an airway pressure of 15 cmH2O, bilateral chest excursion and a square wave capnogram; each item scoring 0 or 1 point). Compared with the neutral position (25.8 ± 5.2 cmH2O), oropharyngeal leak pressure was significantly higher with flexion (28.5 ± 3.4 cmH2O, P=0.015) and lower with extension (23.0 ± 4.2 cmH2O, P=0.015), but similar with rotation (26.7 ± 5.1 cmH2O, P=0.667). Flexion of the head and neck [2 (1-3)] adversely affected the ventilation score compared with the neutral position [3 (2-3), P=0.004]. Effective ventilation with an i-gel can be performed in patients in whom the head and neck is extended or rotated, whereas flexion of the head and neck adversely affects ventilation. Clinically, flexion of the head and neck should be avoided during ventilation with the i-gel.
- 1 August 2011
- Published by Wolters Kluwer Health in European Journal of Anaesthesiology
- Vol. 28 (8) , 597-599
The influence of head and neck position on ventilation with the i-gel airway in paralysed, anaesthetised patients
We hypothesised that head and neck position could affect the effectiveness of ventilation with the i-gel airway. To test this hypothesis, we investigated the influence of different head and neck positions on oropharyngeal sealing pressures and ventilation scores during ventilation with i-gel. A single, experienced supraglottic airway device user inserted the i-gel in 20 paralysed, anaesthetised patients who were scheduled for oral surgery. Oropharyngeal leak pressures and ventilation scores were measured with the head and neck in the neutral position, flexed, extended or rotated to the right. Ventilation was scored from 0 to 3 based on three criteria (no leakage with an airway pressure of 15 cmH2O, bilateral chest excursion and a square wave capnogram; each item scoring 0 or 1 point). Compared with the neutral position (25.8 ± 5.2 cmH2O), oropharyngeal leak pressure was significantly higher with flexion (28.5 ± 3.4 cmH2O, P=0.015) and lower with extension (23.0 ± 4.2 cmH2O, P=0.015), but similar with rotation (26.7 ± 5.1 cmH2O, P=0.667). Flexion of the head and neck [2 (1-3)] adversely affected the ventilation score compared with the neutral position [3 (2-3), P=0.004]. Effective ventilation with an i-gel can be performed in patients in whom the head and neck is extended or rotated, whereas flexion of the head and neck adversely affects ventilation. Clinically, flexion of the head and neck should be avoided during ventilation with the i-gel.
- 1 July 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (7) , e269-e272
Comparison of the Ambu AuraFlex With the Laryngeal Mask Airway Flexible: A Manikin Study
- 1 July 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (7) , e269-e272
Comparison of the Ambu AuraFlex With the Laryngeal Mask Airway Flexible: A Manikin Study
- 1 May 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (5) , 1311-1315
Effects of Head-Neck Extension on Abnormality of Laryngeal Mask Airway Function Resulting From Opening the Mouth
- 1 May 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (5) , 1311-1315
Effects of Head-Neck Extension on Abnormality of Laryngeal Mask Airway Function Resulting From Opening the Mouth
- 1 April 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (4) , 1018-1022
Optimal Degree of Mouth Opening for Laryngeal Mask Airway Function During Oral Surgery
- 1 April 2011
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 69 (4) , 1018-1022
Optimal Degree of Mouth Opening for Laryngeal Mask Airway Function During Oral Surgery
- 1 January 2011
- Published by American Dental Society of Anesthesiology (ADSA) in Anesthesia Progress
- Vol. 58 (3) , 124-125
Modified i-gel Airway for Oral Surgery
- 1 January 2011
- Published by American Dental Society of Anesthesiology (ADSA) in Anesthesia Progress
- Vol. 58 (3) , 124-125
Modified i-gel Airway for Oral Surgery
- 1 May 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (5) , 1038-1042
The Influence of Mouth Opening on Oropharyngeal Leak Pressure, Intracuff Pressure, and Cuff Position With the Laryngeal Mask Airway
- 1 May 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (5) , 1038-1042
The Influence of Mouth Opening on Oropharyngeal Leak Pressure, Intracuff Pressure, and Cuff Position With the Laryngeal Mask Airway
- 1 March 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (3) , 618-621
Epistaxis During Nasotracheal Intubation: A Comparison of Nostril Sides
- 1 March 2010
- Published by Elsevier in Journal of Oral and Maxillofacial Surgery
- Vol. 68 (3) , 618-621
Epistaxis During Nasotracheal Intubation: A Comparison of Nostril Sides