James A. French
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
James A. French has a total of 9 co-authors. Here are the top co-authors by number of shared publications:
- M. Kilchenman O'MAlley
Department of Mechanical Engineering, Rice University, Houston, USA
3 shared publications - Ali Utku Pehlivan
Department of Mechanical Engineering, Rice University, Houston, USA
1 shared publication - Amy A. Blank
Department of Mechanical Engineering, Rice University, Houston, USA
1 shared publication - Anusha Venkatakrishnan
Palo Alto Research Center, Palo Alto, CA, United States
1 shared publication - Chad G. Rose
Rice University, Houston, TX
1 shared publication - Gerard E. Francisco
Department of Physical Medicine and Rehabilitation, The University of Texas Health Science Center at Houston, Houston, Texas
1 shared publication
Latest Publications
- 22 October 2014
- Published by ASME International
- Vol. 2014
System Characterization of MAHI Exo-II: A Robotic Exoskeleton for Upper Extremity Rehabilitation
This paper presents the performance characterization of the MAHI Exo-II, an upper extremity exoskeleton for stroke and spinal cord injury (SCI) rehabilitation, as a means to validate its clinical implementation and to provide depth to the literature on the performance characteristics of upper extremity exoskeletons. Individuals with disabilities arising from stroke and SCI need rehabilitation of the elbow, forearm, and wrist to restore the ability to independently perform activities of daily living (ADL). Robotic rehabilitation has been proposed to address the need for high intensity, long duration therapy and has shown promising results for upper limb proximal joints. However, upper limb distal joints have historically not benefitted from the same focus. The MAHI Exo-II, designed to address this shortcoming, has undergone a static and dynamic performance characterization, which shows that it exhibits the requisite qualities for a rehabilitation robot and is comparable to other state-of-the-art designs.
- 22 October 2014
- Published by ASME International
- Vol. 2014
System Characterization of MAHI Exo-II: A Robotic Exoskeleton for Upper Extremity Rehabilitation
This paper presents the performance characterization of the MAHI Exo-II, an upper extremity exoskeleton for stroke and spinal cord injury (SCI) rehabilitation, as a means to validate its clinical implementation and to provide depth to the literature on the performance characteristics of upper extremity exoskeletons. Individuals with disabilities arising from stroke and SCI need rehabilitation of the elbow, forearm, and wrist to restore the ability to independently perform activities of daily living (ADL). Robotic rehabilitation has been proposed to address the need for high intensity, long duration therapy and has shown promising results for upper limb proximal joints. However, upper limb distal joints have historically not benefitted from the same focus. The MAHI Exo-II, designed to address this shortcoming, has undergone a static and dynamic performance characterization, which shows that it exhibits the requisite qualities for a rehabilitation robot and is comparable to other state-of-the-art designs.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 4127-4130
Detecting movement intent from scalp EEG in a novel upper limb robotic rehabilitation system for stroke
Stroke can be a source of significant upper extremity dysfunction and affect the quality of life (QoL) in survivors. In this context, novel rehabilitation approaches employing robotic rehabilitation devices combined with brain-machine interfaces can greatly help in expediting functional recovery in these individuals by actively engaging the user during therapy. However, optimal training conditions and parameters for these novel therapeutic systems are still unknown. Here, we present preliminary findings demonstrating successful movement intent detection from scalp electroencephalography (EEG) during robotic rehabilitation using the MAHI Exo-II in an individual with hemiparesis following stroke. These findings have strong clinical implications for the development of closed-loop brain-machine interfaces to robotic rehabilitation systems.
- 1 August 2014
- Published by Institute of Electrical and Electronics Engineers (IEEE) in 2018 40th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC)
- Vol. 2014 (1094687X) , 4127-4130
Detecting movement intent from scalp EEG in a novel upper limb robotic rehabilitation system for stroke
Stroke can be a source of significant upper extremity dysfunction and affect the quality of life (QoL) in survivors. In this context, novel rehabilitation approaches employing robotic rehabilitation devices combined with brain-machine interfaces can greatly help in expediting functional recovery in these individuals by actively engaging the user during therapy. However, optimal training conditions and parameters for these novel therapeutic systems are still unknown. Here, we present preliminary findings demonstrating successful movement intent detection from scalp electroencephalography (EEG) during robotic rehabilitation using the MAHI Exo-II in an individual with hemiparesis following stroke. These findings have strong clinical implications for the development of closed-loop brain-machine interfaces to robotic rehabilitation systems.
- Top Cited Papers
- 28 June 2014
- Published by Springer Nature in Current Physical Medicine and Rehabilitation Reports
- Vol. 2 (3) , 184-195
Current Trends in Robot-Assisted Upper-Limb Stroke Rehabilitation: Promoting Patient Engagement in Therapy
Stroke is one of the leading causes of long-term disability today; therefore, many research efforts are focused on designing maximally effective and efficient treatment methods. In particular, robotic stroke rehabilitation has received significant attention for upper-limb therapy due to its ability to provide high-intensity repetitive movement therapy with less effort than would be required for traditional methods. Recent research has focused on increasing patient engagement in therapy, which has been shown to be important for inducing neural plasticity to facilitate recovery. Robotic therapy devices enable unique methods for promoting patient engagement by providing assistance only as needed and by detecting patient movement intent to drive to the device. Use of these methods has demonstrated improvements in functional outcomes, but careful comparisons between methods remain to be done. Future work should include controlled clinical trials and comparisons of effectiveness of different methods for patients with different abilities and needs in order to inform future development of patient-specific therapeutic protocols.
- 28 June 2014
- Published by Springer Nature in Current Physical Medicine and Rehabilitation Reports
- Vol. 2 (3) , 184-195
Top Cited PapersCurrent Trends in Robot-Assisted Upper-Limb Stroke Rehabilitation: Promoting Patient Engagement in Therapy
Stroke is one of the leading causes of long-term disability today; therefore, many research efforts are focused on designing maximally effective and efficient treatment methods. In particular, robotic stroke rehabilitation has received significant attention for upper-limb therapy due to its ability to provide high-intensity repetitive movement therapy with less effort than would be required for traditional methods. Recent research has focused on increasing patient engagement in therapy, which has been shown to be important for inducing neural plasticity to facilitate recovery. Robotic therapy devices enable unique methods for promoting patient engagement by providing assistance only as needed and by detecting patient movement intent to drive to the device. Use of these methods has demonstrated improvements in functional outcomes, but careful comparisons between methods remain to be done. Future work should include controlled clinical trials and comparisons of effectiveness of different methods for patients with different abilities and needs in order to inform future development of patient-specific therapeutic protocols.