Yan Wang
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Yan Wang has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Declan T Millett
Oral Health and Development; Cork University Dental School and Hospital; Cork Ireland
5 shared publicationsFan Jian
State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Orthodontics; West China Hospital of Stomatology, Sichuan University; Chengdu China
5 shared publicationsWenli Lai
State Key Laboratory of Oral Diseases, National Center for Stomatology, National Clinical Research Center for Oral Diseases, Department of Orthodontics; West China Hospital of Stomatology, Sichuan University; Chengdu China
5 shared publicationsJoy Hickman
Glan Clwyd Hospital; Department of Orthodontics; Rhyl UK LL18 5UJ
4 shared publications- Chang Liu
State Key Laboratory of Oral Diseases & National Center for Stomatology & National Clinical Research Center for Oral Diseases & Department of Oral and Maxillofacial Surgery, West China Hospital of Stomatology, Sichuan University, Chengdu, China
2 shared publications Grant T McIntyre
University of Dundee; School of Dentistry; 2 Park Place Dundee Scotland UK DD1 4HR
2 shared publications
Latest Publications
- 6 February 2024
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2024 (2) , CD007859
Initial arch wires used in orthodontic treatment with fixed appliances
Background Initial arch wires are the first arch wires inserted into fixed appliance at the beginning of orthodontic treatment. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which are most efficient and which cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is the third update of a Cochrane review first published in 2010. Objectives To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. Search methods We searched Cochrane Oral Health's Trials Register, CENTRAL, MEDLINE, Embase, and two ongoing trials registries on 4 July 2022. Selection criteria We included randomised controlled trials (RCTs) of different initial arch wires used to align teeth with fixed orthodontic braces. We included people with full‐arch fixed orthodontic appliances on the upper arch, lower arch, or both arches. Data collection and analysis Two independent review authors were responsible for study selection, data extraction, and assessment of risk of bias in included studies. We contacted corresponding authors of included studies to obtain missing information. We resolved disagreements by discussion between the review authors. Our main outcomes were alignment rate (movement of teeth in mm), root resorption, time to alignment, and intensity of pain measured on a 100‐mm visual analogue scale (VAS). We pooled data from studies with similar interventions and outcomes using random‐effects models. We reported mean differences (MDs) with 95% confidence intervals (CIs) for continuous data, risk ratios (RRs) with 95% CIs for dichotomous data, and alignment rate ratios with 95% CIs for time‐to‐event data. Two independent review authors assessed the certainty of evidence. We resolved disagreements by discussion between the review authors. Main results We included 29 RCTs with 1915 participants (2581 arches) in this review. Studies were generally small (sample sizes ranged from 14 to 200 participants). Duration of follow‐up varied between three days and six months. Eleven studies received funding, six received no funding, and 12 provided no information about funding sources. We judged eight studies at high risk of bias, nine at low risk, and 12 at unclear risk. We grouped the studies into six main comparisons. Multistrand stainless steel wires versus wires composed of other materials Six studies with 409 participants (545 arches) evaluated multistrand stainless steel (StSt) wires versus wires composed of other materials. We are very uncertain about the effect of multistrand StSt wires versus other wires on alignment rate (4 studies, 281 participants, 417 arches; very low‐certainty evidence). There may be little to no difference between multistrand StSt wires and other wires in terms of intensity of pain (MD −2.68 mm, 95% CI −6.75 to 1.38; 2 studies, 127 participants, 127 arches; low‐certainty evidence). Conventional nickel‐titanium wires versus superelastic nickel‐titanium wires Four studies with 266 participants (274 arches) evaluated conventional nickel‐titanium (NiTi) wires versus superelastic NiTi wires. There may be little to no difference between the different wire types in terms of alignment rate (124 participants, 124 arches, 2 studies; low‐certainty evidence) and intensity of pain (MD −0.29 mm, 95% CI −1.10 to 0.52; 2 studies, 142 participants, 150 arches; low‐certainty evidence). Conventional nickel‐titanium wires versus thermoelastic copper‐nickel‐titanium wires Three studies with 210 participants (210 arches) evaluated conventional Ni‐Ti versus thermoelastic copper‐nickel‐titanium (CuNiTi) wires. We are very uncertain about the effects of the different arch wires on alignment rate (1 study, 66 participants, 66 arches; very low‐certainty evidence). There may be little to no difference between conventional NiTi wires and thermoelastic CuNiTi wires in terms of time to alignment (alignment rate ratio 1.30, 95% CI 0.68 to 2.50; 1 study, 60 participants, 60 arches; low‐certainty evidence). Superelastic nickel‐titanium wires versus thermoelastic nickel‐titanium wires Twelve studies with 703 participants (936 arches) evaluated superelastic NiTi versus thermoelastic NiTi wires. There may be little to no difference between superelastic NiTi wires and thermoelastic NiTi wires in alignment rate at four weeks (MD −0.28 mm, 95% CI 0.62 to 0.06; 5 studies, 183 participants, 183 arches; low‐certainty evidence). We are very uncertain about the effects of the different wires on root resorption (2 studies, 52 participants, 312 teeth; very low‐certainty evidence). Superelastic NiTi wires compared with thermoelastic NiTi wires may result in a slight increase in time to alignment (MD 0.5 months, 95% CI 0.21 to 0.79; 1 study, 32 participants, 32 arches; low‐certainty evidence) but are probably associated with a slight increase in intensity of pain (MD 6.96 mm, 95% CI 1.82 to 12.10; 3 studies, 94 participants, 138 arches, moderate‐certainty evidence). Single‐strand superelastic nickel‐titanium wires versus coaxial superelastic nickel‐titanium wires Three studies with 104 participants (104 arches) evaluated single‐strand superelastic NiTi versus coaxial superelastic NiTi wires. Use of single‐strand superelastic NiTi wires compared with coaxial superelastic NiTi wires probably results in a slight reduction in alignment rate at four weeks (MD −2.64 mm, 95% CI −4.61 to −0.67; 2 studies, 64 participants, 64 arches,...
- 6 February 2024
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2024 (2) , CD007859
Initial arch wires used in orthodontic treatment with fixed appliances
Background Initial arch wires are the first arch wires inserted into fixed appliance at the beginning of orthodontic treatment. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which are most efficient and which cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is the third update of a Cochrane review first published in 2010. Objectives To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. Search methods We searched Cochrane Oral Health's Trials Register, CENTRAL, MEDLINE, Embase, and two ongoing trials registries on 4 July 2022. Selection criteria We included randomised controlled trials (RCTs) of different initial arch wires used to align teeth with fixed orthodontic braces. We included people with full‐arch fixed orthodontic appliances on the upper arch, lower arch, or both arches. Data collection and analysis Two independent review authors were responsible for study selection, data extraction, and assessment of risk of bias in included studies. We contacted corresponding authors of included studies to obtain missing information. We resolved disagreements by discussion between the review authors. Our main outcomes were alignment rate (movement of teeth in mm), root resorption, time to alignment, and intensity of pain measured on a 100‐mm visual analogue scale (VAS). We pooled data from studies with similar interventions and outcomes using random‐effects models. We reported mean differences (MDs) with 95% confidence intervals (CIs) for continuous data, risk ratios (RRs) with 95% CIs for dichotomous data, and alignment rate ratios with 95% CIs for time‐to‐event data. Two independent review authors assessed the certainty of evidence. We resolved disagreements by discussion between the review authors. Main results We included 29 RCTs with 1915 participants (2581 arches) in this review. Studies were generally small (sample sizes ranged from 14 to 200 participants). Duration of follow‐up varied between three days and six months. Eleven studies received funding, six received no funding, and 12 provided no information about funding sources. We judged eight studies at high risk of bias, nine at low risk, and 12 at unclear risk. We grouped the studies into six main comparisons. Multistrand stainless steel wires versus wires composed of other materials Six studies with 409 participants (545 arches) evaluated multistrand stainless steel (StSt) wires versus wires composed of other materials. We are very uncertain about the effect of multistrand StSt wires versus other wires on alignment rate (4 studies, 281 participants, 417 arches; very low‐certainty evidence). There may be little to no difference between multistrand StSt wires and other wires in terms of intensity of pain (MD −2.68 mm, 95% CI −6.75 to 1.38; 2 studies, 127 participants, 127 arches; low‐certainty evidence). Conventional nickel‐titanium wires versus superelastic nickel‐titanium wires Four studies with 266 participants (274 arches) evaluated conventional nickel‐titanium (NiTi) wires versus superelastic NiTi wires. There may be little to no difference between the different wire types in terms of alignment rate (124 participants, 124 arches, 2 studies; low‐certainty evidence) and intensity of pain (MD −0.29 mm, 95% CI −1.10 to 0.52; 2 studies, 142 participants, 150 arches; low‐certainty evidence). Conventional nickel‐titanium wires versus thermoelastic copper‐nickel‐titanium wires Three studies with 210 participants (210 arches) evaluated conventional Ni‐Ti versus thermoelastic copper‐nickel‐titanium (CuNiTi) wires. We are very uncertain about the effects of the different arch wires on alignment rate (1 study, 66 participants, 66 arches; very low‐certainty evidence). There may be little to no difference between conventional NiTi wires and thermoelastic CuNiTi wires in terms of time to alignment (alignment rate ratio 1.30, 95% CI 0.68 to 2.50; 1 study, 60 participants, 60 arches; low‐certainty evidence). Superelastic nickel‐titanium wires versus thermoelastic nickel‐titanium wires Twelve studies with 703 participants (936 arches) evaluated superelastic NiTi versus thermoelastic NiTi wires. There may be little to no difference between superelastic NiTi wires and thermoelastic NiTi wires in alignment rate at four weeks (MD −0.28 mm, 95% CI 0.62 to 0.06; 5 studies, 183 participants, 183 arches; low‐certainty evidence). We are very uncertain about the effects of the different wires on root resorption (2 studies, 52 participants, 312 teeth; very low‐certainty evidence). Superelastic NiTi wires compared with thermoelastic NiTi wires may result in a slight increase in time to alignment (MD 0.5 months, 95% CI 0.21 to 0.79; 1 study, 32 participants, 32 arches; low‐certainty evidence) but are probably associated with a slight increase in intensity of pain (MD 6.96 mm, 95% CI 1.82 to 12.10; 3 studies, 94 participants, 138 arches, moderate‐certainty evidence). Single‐strand superelastic nickel‐titanium wires versus coaxial superelastic nickel‐titanium wires Three studies with 104 participants (104 arches) evaluated single‐strand superelastic NiTi versus coaxial superelastic NiTi wires. Use of single‐strand superelastic NiTi wires compared with coaxial superelastic NiTi wires probably results in a slight reduction in alignment rate at four weeks (MD −2.64 mm, 95% CI −4.61 to −0.67; 2 studies, 64 participants, 64 arches,...
- 31 July 2018
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2018 (7) , CD007859
Initial arch wires used in orthodontic treatment with fixed appliances
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review entitledInitial arch wires for alignment of crooked teeth with fixed orthodontic braces, which was first published in 2010. To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 5 October 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 9), MEDLINE Ovid (1946 to 5 October 2017), and Embase Ovid (1980 to 5 October 2017. The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. We included only studies involving participants with upper or lower, or both, full arch fixed orthodontic appliances. Two review authors were responsible for study selection, 'Risk of bias' assessment and data extraction. We resolved disagreements by discussion between the review authors. We contacted corresponding authors of included studies to obtain missing information. We assessed the quality of the evidence for each comparison and outcome as high, moderate, low or very low, according to GRADE criteria. For this update, we found three new RCTs (228 participants), bringing the total to 12 RCTs with 799 participants. We judged three studies to be at high risk of bias, and three to be at low risk of bias; six were unclear. None of the studies reported the adverse outcome of root resorption. The review assessed six comparisons. 1. Multistrand stainless steel versus superelastic nickel-titanium (NiTi) arch wires. There were five studies in this group and it was appropriate to undertake a meta-analysis of two of them. There is insufficient evidence from these studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and superelastic NiTi arch wires (mean difference (MD) -7.5 mm per month, 95% confidence interval (CI) -26.27 to 11.27; 1 study, 48 participants; low-quality evidence). The findings for pain at day 1 as measured on a 100 mm visual analogue scale suggested that there was no meaningful difference between the interventions (MD -2.68 mm, 95% CI -6.75 to 1.38; 2 studies, 127 participants; moderate-quality evidence). 2. Multistrand stainless steel versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from the studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 3. Conventional NiTi versus superelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is any difference between conventional and superelastic NiTi arch wires with regard to either alignment or pain (low- to very low-quality evidence). 4. Conventional NiTi versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment between conventional and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 5. Single-strand superelastic NiTi versus coaxial superelastic NiTi arch wires. There was only one study (24 participants) in this group. There is moderate-quality evidence that coaxial superelastic NiTi can produce greater tooth movement over 12 weeks (MD -6.76 mm, 95% CI -7.98 to -5.55). Pain was not measured. 6. Superelastic NiTi versus thermoelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment or pain between superelastic and thermoelastic NiTi arch wires (low-quality evidence). Moderate-quality evidence shows that arch wires of coaxial superelastic nickel-titanium (NiTi) can produce greater tooth movement over 12 weeks than arch wires made of single-strand superelastic NiTi. Moderate-quality evidence also suggests there may be no difference in pain at day 1 between multistrand stainless steel arch wires and superelastic NiTi arch wires. Other than these findings, there is insufficient evidence to determine whether any particular arch wire material is superior to any other in terms of alignment rate, time to alignment, pain and root resorption.
- 31 July 2018
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2018 (7) , CD007859
Initial arch wires used in orthodontic treatment with fixed appliances
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review entitledInitial arch wires for alignment of crooked teeth with fixed orthodontic braces, which was first published in 2010. To assess the effects of initial arch wires for the alignment of teeth with fixed orthodontic braces, in terms of the rate of tooth alignment, amount of root resorption accompanying tooth movement, and intensity of pain experienced by patients during the initial alignment stage of treatment. Cochrane Oral Health's Information Specialist searched the following databases: Cochrane Oral Health's Trials Register (to 5 October 2017), the Cochrane Central Register of Controlled Trials (CENTRAL) (the Cochrane Library, 2017, Issue 9), MEDLINE Ovid (1946 to 5 October 2017), and Embase Ovid (1980 to 5 October 2017. The US National Institutes of Health Trials Registry (ClinicalTrials.gov) and the World Health Organization International Clinical Trials Registry Platform were searched for ongoing trials. No restrictions were placed on the language or date of publication when searching the electronic databases. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. We included only studies involving participants with upper or lower, or both, full arch fixed orthodontic appliances. Two review authors were responsible for study selection, 'Risk of bias' assessment and data extraction. We resolved disagreements by discussion between the review authors. We contacted corresponding authors of included studies to obtain missing information. We assessed the quality of the evidence for each comparison and outcome as high, moderate, low or very low, according to GRADE criteria. For this update, we found three new RCTs (228 participants), bringing the total to 12 RCTs with 799 participants. We judged three studies to be at high risk of bias, and three to be at low risk of bias; six were unclear. None of the studies reported the adverse outcome of root resorption. The review assessed six comparisons. 1. Multistrand stainless steel versus superelastic nickel-titanium (NiTi) arch wires. There were five studies in this group and it was appropriate to undertake a meta-analysis of two of them. There is insufficient evidence from these studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and superelastic NiTi arch wires (mean difference (MD) -7.5 mm per month, 95% confidence interval (CI) -26.27 to 11.27; 1 study, 48 participants; low-quality evidence). The findings for pain at day 1 as measured on a 100 mm visual analogue scale suggested that there was no meaningful difference between the interventions (MD -2.68 mm, 95% CI -6.75 to 1.38; 2 studies, 127 participants; moderate-quality evidence). 2. Multistrand stainless steel versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from the studies to determine whether there is a difference in rate of alignment between multistrand stainless steel and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 3. Conventional NiTi versus superelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is any difference between conventional and superelastic NiTi arch wires with regard to either alignment or pain (low- to very low-quality evidence). 4. Conventional NiTi versus thermoelastic NiTi arch wires. There were two studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment between conventional and thermoelastic NiTi arch wires (low-quality evidence). Pain was not measured. 5. Single-strand superelastic NiTi versus coaxial superelastic NiTi arch wires. There was only one study (24 participants) in this group. There is moderate-quality evidence that coaxial superelastic NiTi can produce greater tooth movement over 12 weeks (MD -6.76 mm, 95% CI -7.98 to -5.55). Pain was not measured. 6. Superelastic NiTi versus thermoelastic NiTi arch wires. There were three studies in this group, but it was not appropriate to undertake a meta-analysis of the data. There is insufficient evidence from these studies to determine whether there is a difference in alignment or pain between superelastic and thermoelastic NiTi arch wires (low-quality evidence). Moderate-quality evidence shows that arch wires of coaxial superelastic nickel-titanium (NiTi) can produce greater tooth movement over 12 weeks than arch wires made of single-strand superelastic NiTi. Moderate-quality evidence also suggests there may be no difference in pain at day 1 between multistrand stainless steel arch wires and superelastic NiTi arch wires. Other than these findings, there is insufficient evidence to determine whether any particular arch wire material is superior to any other in terms of alignment rate, time to alignment, pain and root resorption.
- 10 September 2014
- Published by Wiley in ChemMedChem
- Vol. 10 (1) , 57-61
Discovery and Characterization of 2‐(Cyclopropanesulfonamido)‐N‐(2‐ethoxyphenyl)benzamide, ML382: a Potent and Selective Positive Allosteric Modulator of MrgX1
Previous studies have shown that the activation of mouse MrgC11, a G‐protein‐coupled receptor, by its peptide ligand BAM8‐22 can inhibit chronic pain. A large‐scale screen has been carried out to isolate small‐molecule allosteric agonists of MrgX1, the human homologue of MrgC11. The goal of this study is to improve the efficacy and potency of positive allosteric modulators (PAMs) with therapeutic implications in combating chronic pain. Herein we report an iterative parallel synthesis effort and a structure–activity relationship study of a series of arylsulfonamides which led to the discovery of the first PAM of MrgX1, ML382.
- 10 September 2014
- Published by Wiley in ChemMedChem
- Vol. 10 (1) , 57-61
Discovery and Characterization of 2‐(Cyclopropanesulfonamido)‐N‐(2‐ethoxyphenyl)benzamide, ML382: a Potent and Selective Positive Allosteric Modulator of MrgX1
Previous studies have shown that the activation of mouse MrgC11, a G‐protein‐coupled receptor, by its peptide ligand BAM8‐22 can inhibit chronic pain. A large‐scale screen has been carried out to isolate small‐molecule allosteric agonists of MrgX1, the human homologue of MrgC11. The goal of this study is to improve the efficacy and potency of positive allosteric modulators (PAMs) with therapeutic implications in combating chronic pain. Herein we report an iterative parallel synthesis effort and a structure–activity relationship study of a series of arylsulfonamides which led to the discovery of the first PAM of MrgX1, ML382.
- 30 April 2013
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2013 (4) , CD007859
Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4. To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one potentially confounding factor (such as bracket type, slot size, ligation method, extraction of teeth) which is likely to have influenced the outcome and was not controlled in the trial. None of the trials reported the important adverse outcome of root resorption.Three groups of comparisons were made.(1) Multistrand stainless steel initial arch wires compared to superelastic nickel titanium (NiTi) initial arch wires. There were four trials in this group, with different comparisons and outcomes reported at different times. No meta-analysis was possible. There is insufficient evidence from these trials to determine whether or not there is a difference in either rate of alignment or pain between stainless steel and NiTi initial arch wires.(2) Conventional (stabilised) NiTi initial arch wires compared to superelastic NiTi initial arch wires. There were two trials in this group, one reporting the outcome of alignment over 6 months and the other reporting pain over 1 week. There is insufficient evidence from these trials to determine whether or not there is any difference between conventional (stabilised) and superelastic NiTi initial arch wires with regard to either alignment or pain.(3) Single-strand superelastic NiTi initial arch wires compared to other NiTi (coaxial, copper NiTi (CuNiTi) or thermoelastic) initial arch wires. The three trials in this comparison each compared a different product against single-strand superelastic NiTi. There is very weak unreliable evidence, based on one very small study (n = 24) at high risk of bias, that coaxial superelastic NiTi may produce greater tooth movement over 12 weeks, but no information on associated pain or root resorption. This result should be interpreted with caution until further research evidence is available. There is insufficient evidence to determine whether or not there is a difference between either thermoelastic or CuNiTi and superelastic NiTi initial arch wires. There is no reliable evidence from the trials included in this review that any specific initial arch wire material is better or worse than another with regard to speed of alignment or pain. There is no evidence at all about the effect of initial arch wire materials on the important adverse effect of root resorption. Further well-designed and conducted, adequately-powered, RCTs are required to determine whether the performance of initial arch wire materials as demonstrated in the laboratory, makes a clinically important difference to the alignment of teeth in the initial stage of orthodontic treatment in patients.
- 30 April 2013
- Published by Wiley in Cochrane Database of Systematic Reviews
- Vol. 2013 (4) , CD007859
Initial arch wires for tooth alignment during orthodontic treatment with fixed appliances
Initial arch wires are the first arch wires to be inserted into the fixed appliance at the beginning of orthodontic treatment and are used mainly for the alignment of teeth by correcting crowding and rotations. With a number of different types of orthodontic arch wires available for initial tooth alignment, it is important to understand which wire is most efficient, as well as which wires cause the least amount of root resorption and pain during the initial aligning stage of treatment. This is an update of the review 'Initial arch wires for alignment of crooked teeth with fixed orthodontic braces' first published in the Cochrane Database of Systematic Reviews 2010, Issue 4. To assess the effects of initial arch wires for alignment of teeth with fixed orthodontic braces in relation to alignment speed, root resorption and pain intensity. We searched the following electronic databases: the Cochrane Oral Health Group's Trials Register (to 2 August 2012), CENTRAL (The Cochrane Library 2012, Issue 7), MEDLINE via OVID (1950 to 2 August 2012) and EMBASE via OVID (1980 to 2 August 2012). We also searched the reference lists of relevant articles. There was no restriction with regard to publication status or language of publication. We contacted all authors of included studies to identify additional studies. We included randomised controlled trials (RCTs) of initial arch wires to align teeth with fixed orthodontic braces. Only studies involving participants with upper and/or lower full arch fixed orthodontic appliances were included. Two review authors were responsible for study selection, validity assessment and data extraction. All disagreements were resolved by discussion amongst the review team. Corresponding authors of included studies were contacted to obtain missing information. Nine RCTs with 571 participants were included in this review. All trials were at high risk of bias and a number of methodological limitations were identified. All trials had at least one potentially confounding factor (such as bracket type, slot size, ligation method, extraction of teeth) which is likely to have influenced the outcome and was not controlled in the trial. None of the trials reported the important adverse outcome of root resorption.Three groups of comparisons were made.(1) Multistrand stainless steel initial arch wires compared to superelastic nickel titanium (NiTi) initial arch wires. There were four trials in this group, with different comparisons and outcomes reported at different times. No meta-analysis was possible. There is insufficient evidence from these trials to determine whether or not there is a difference in either rate of alignment or pain between stainless steel and NiTi initial arch wires.(2) Conventional (stabilised) NiTi initial arch wires compared to superelastic NiTi initial arch wires. There were two trials in this group, one reporting the outcome of alignment over 6 months and the other reporting pain over 1 week. There is insufficient evidence from these trials to determine whether or not there is any difference between conventional (stabilised) and superelastic NiTi initial arch wires with regard to either alignment or pain.(3) Single-strand superelastic NiTi initial arch wires compared to other NiTi (coaxial, copper NiTi (CuNiTi) or thermoelastic) initial arch wires. The three trials in this comparison each compared a different product against single-strand superelastic NiTi. There is very weak unreliable evidence, based on one very small study (n = 24) at high risk of bias, that coaxial superelastic NiTi may produce greater tooth movement over 12 weeks, but no information on associated pain or root resorption. This result should be interpreted with caution until further research evidence is available. There is insufficient evidence to determine whether or not there is a difference between either thermoelastic or CuNiTi and superelastic NiTi initial arch wires. There is no reliable evidence from the trials included in this review that any specific initial arch wire material is better or worse than another with regard to speed of alignment or pain. There is no evidence at all about the effect of initial arch wire materials on the important adverse effect of root resorption. Further well-designed and conducted, adequately-powered, RCTs are required to determine whether the performance of initial arch wire materials as demonstrated in the laboratory, makes a clinically important difference to the alignment of teeth in the initial stage of orthodontic treatment in patients.
- 11 July 2012
- Published by Wiley
Direct versus indirect bonding for bracket placement in orthodontic patients
- 11 July 2012
- Published by Wiley
Direct versus indirect bonding for bracket placement in orthodontic patients
- 8 July 2009
- Published by Wiley
- No. 3
Initial arch wires for alignment of crooked teeth with fixed orthodontic braces
- 8 July 2009
- Published by Wiley
- No. 3
Initial arch wires for alignment of crooked teeth with fixed orthodontic braces