XQXuejiao Qin

Xuejiao Qin

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Xuejiao Qin has a total of 63 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    COMPARABLE RESULTS OF SUBRETINAL INJECTION AND INTRAVITREAL INJECTION OF TISSUE PLASMINOGEN ACTIVATOR IN THE TREATMENT OF SUBMACULAR HEMORRHAGE

    by Lu Zhang, Yue Zhang, Wenyi Si, Xinyu Wang, Shiyu Jiang, Xuejiao Qin

    Purpose: To estimate the efficacy of intravitreal injection (IVI) versus subretinal injection (SRI) of tissue plasminogen activator in the treatment of submacular hemorrhage (SMH). Methods: A comprehensive literature search was conducted in six major data sets from inception to 31 October 2025. Random effects meta-analysis was performed to evaluate the final best-corrected visual acuity (BCVA, logMAR) and the changes in central retinal thickness (CRT, μm), and the risk ratio of complete displacement of hemorrhage. Results: A total of seven studies on 353 eyes were finally included. Best-corrected visual acuity was similar between the IVI and SRI groups at 1 month and 6 months postoperation, while better in the IVI group 3 months postoperatively. The final CRT was similar between the two groups. There were no statistical differences between the two groups in the RRs of complete displacement of hemorrhage, total adverse events, recurrent SMH, increased intraocular pressure, postoperative retinal detachment, and vitreous hemorrhages. Conclusion: The IVI group showed a better BCVA at 3 months, the two groups showed comparable results in the recovery of BCVA, CRT, and complete hemorrhage displacement at the final visit (within 6 months).

  • Open Access

    Potential Value of Novel Lipid-Derived Indicator as a Biomarker for Nonarteritic Anterior Ischemic Optic Neuropathy

    by Chenyang Cong, Wentong Yan, Yongqing Liu, Jingyao Song, Xuejiao Qin, Bing Liu

    This study aimed to assess the role of novel lipid-related indices in patients with nonarteritic anterior ischemic optic neuropathy (NAION) and investigate the correlation between these indices and NAION severity. All participants underwent comprehensive ocular examinations and serum lipid analysis. Novel lipid-related indices, including the atherogenic index of plasma (AIP), non-high-density lipoprotein cholesterol (HDL-C)/HDL-C ratio, and triglyceride glucose (TyG) index, were calculated using traditional lipid parameters and subsequently compared between patients with NAION and control participants. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the predictive values of these indices. Correlations between novel lipid-related indices and NAION severity were also investigated. Forty-four patients with NAION and 42 control participants were included in this study. The levels of AIP and TyG were significantly elevated in patients with NAION compared to control participants, whereas the traditional lipid parameters in both groups remained within normal limits. The areas under the ROC curves for AIP and TyG were 0.725 and 0.758, respectively. Additionally, no significant correlations were observed among AIP, TyG, best-corrected visual acuity, peripapillary retinal nerve fiber layer thickness, and mean deviation on visual field test. Elevated levels of AIP and TyG were observed in patients with NAION in this study, suggesting that AIP and TyG may serve as systemic metabolic risk markers significantly associated with NAION. The findings of this study help us better understand the underlying mechanisms of NAION and improve its diagnosis and management.

  • Open Access

    Effect of size of capsulorhexis on the outcome of cataract surgery: a protocol for systematic review and individual participant data meta-analysis

    by Songhong Wang, Tiexi Wu, Yue Zhang, Yue Liu, Xuejiao Qin

    Introduction In the era of functional intraocular lens (IOL) implantation, it is crucial to investigate the influence of different capsulorhexis sizes (including the diameter of the capsulorhexis, area of the anterior capsule opening, anterior capsule coverage, centration and circularity of the capsulorhexis) on the postoperative outcomes (eg, visual acuity, capsule shrinkage, IOL stability and intraocular pressure) in patients undergoing cataract surgery. This is particularly important in patients with high myopia or diabetes mellitus. The proposed protocol aims to enhance the transparency of our research and offer references for future studies. Methods and analysis A comprehensive search of PubMed, Embase, Cochrane Library, Web of Science, SinoMed, China National Knowledge Infrastructure, Wanfang Data Knowledge Service Platform and China Science and Technology Journal Database is performed from inception to 4 July 2024. Data of individual participants will be collected from relevant clinical trials, both completed and ongoing. The collected data will be analysed using multilevel regression models to examine the association between capsulorhexis size and surgical outcomes. Potential demographic and clinical factors that may influence the results of cataract surgery, including postoperative visual acuity and IOL rotational stability, will also be explored. Any future modification to this protocol will include the date and rationale for the change. Ethics and dissemination Ethical approval is not required because the study does not involve individual patients. The study results are to be disseminated via professional journals as well as academic media. Trial registration number CRD42023459903.


  • Open Access

    Transcriptome sequencing and Mendelian randomization analysis identified biomarkers related to neutrophil extracellular traps in diabetic retinopathy

    by Linlin Hao, Songhong Wang, Lian Zhang, Jie Huang, Yue Zhang, Xuejiao Qin

    Summary: In the development of diabetic retinopathy (DR), neutrophil infiltration hastens the adhesion between neutrophils and endothelial cells, leading to inflammation. Meanwhile, neutrophil extracellular traps (NETs) produced by neutrophils could clear aging blood vessels, setting the stage for retinal vascular regeneration. To explore the mechanism of NETs-related genes in DR, the transcriptome of NETs from normal and DR individuals were analyzed with gene sequencing and mendelian randomization (MR) analysis. Five NETs-related genes were identified as key genes. Among these genes, CLIC3, GBP2, and P2RY12 were found to be risk factors for Proliferative DR(PDR), whereas HOXA1 and PSAP were protective factors. Further verification by qRT-PCR recognized GBP2, P2RY12 and PSAP as NETs-associated biomarkers in PDR.Purpose: To investigate neutrophil extracellular traps (NETs) related genes as biomarkers in the progression of diabetic retinopathy (DR).Methods: We collected whole blood samples from 10 individuals with DR and 10 normal controls (NCs) for transcriptome sequencing. Following quality control and preprocessing of the sequencing data, differential expression analysis was conducted to identify differentially expressed genes (DEGs) between the DR and NC groups. Candidate genes were then selected by intersecting these DEGs with key module genes identified through weighted gene co-expression network analysis. These candidate genes were subjected to mendelian randomization (MR) analysis, then least absolute shrinkage and selection operator analysis to pinpoint key genes. The diagnostic utility of these key genes was evaluated using receiver operating characteristic curve analysis, and their expression levels were examined. Additional analysis, including nomogram construction, gene set enrichment analysis, drug prediction and molecular docking, were performed to investigate the functions and molecular mechanisms of the key genes. Finally, the expression of key genes was verified by qRT-PCR and biomarkers were identified.Results: Intersection of 1,004 DEGs with 1,038 key module genes yielded 291 candidate genes. Five key genes were identified: HOXA1, GBP2, P2RY12, CLIC3 and PSAP. Among them, CLIC3, GBP2, and P2RY12 were identified as risk factors for DR, while HOXA1 and PSAP were protective. These key genes demonstrated strong diagnostic performance for DR. With the exception of P2RY12, all other key genes exhibited down-regulation in the DR group. Furthermore, the nomogram incorporating multiple key genes demonstrated superior predictive capacity for DR compared to a single key genes. The identified key genes are involved in oxidative phosphorylation and ribosome functions. Drug predictions targeting P2RY12 suggested prasugrel, ticagrelor, and ticlopidine as potential options owing to their high binding affinity with this key genes. The qRT-PCR results revealed that the results of GBP2, PSAP and P2RY12 exhibited consistent expression patterns with the dataset.Conclusion: This study identified GBP2, P2RY12 and PSAP as NETs-associated biomarkers in the development of PDR, offering new insights for clinical diagnosis and potential treatment strategies for DR.


  • Open Access

    Genetic correlation and causal relationship between sleep and myopia: a mendelian randomization study

    by Guandong Zhu, Ruikang Tian, Dengke Zhou, Xuejiao Qin

    Purpose: To investigate the genetic correlation and causal links between sleep traits (including sleep duration, chronotype, and insomnia) and myopia.Methods: Summary data on three sleep traits (sleep duration, chronotype and insomnia) and myopia from FinnGen (n = 214,211) and UK Biobank (n = 460,536) were analyzed using linkage disequilibrium score regression (LD Score), univariable and multivariable mendelian randomization (MR) experiments and Causal Analysis Using Summary Effect (CAUSE) estimation.Results: LD Score regression detected candidate genetic correlation between sleep traits and myopia, such as sleep duration, chronotype (Genetic Correlation Z-score >10.00, h2_observed_p < 0.005, Lambda GC > 1.05, p > 0.05). Univariable MR analyses indicated that increased sleep duration has a promotional effect on the occurrence of myopia (p = 0.046 < 0.05, P_FDR = 0.138 < 0.2, OR = 2.872, 95% CI: 1.018–8.101). However, after accounting for potential confounding factors, multivariable MR and CAUSE analysis did not provide evidence for a causal effect of the three sleep traits on myopia.Conclusion: There may be a potential genetic correlation between sleep duration, chronotype and myopia. However, neither of sleep duration, chronotype or insomnia had causal effect on myopia.


  • Leukocoria Due to Persistent Hyperplastic Primary Vitreous

    by Shaohua Liu, Linlin Hao, Xuejiao Qin

    This case report discusses a diagnosis of persistent hyperplastic primary vitreous presenting as leukocoria in a boy aged 50 days.

  • Open Access

    Quantitative assessment of OCT and OCTA parameters in diabetic retinopathy with and without macular edema: single-center cross-sectional analysis

    by Yanyan Cui, Dongfan Feng, Changlong Wu, Ping Wang, Ruoxi Cui, Xiaokun Wang, Weiwei Chang, Weiwei Shang, Bojun Zhao, Jing Liu, et al.

    Aim: The retinal and choroidal parameters were analyzed to understand the impairment of microcirculation of both retina and choroid in patients with diabetic retinopathy (DR).Methods: Fifty-five treatment-naive non-proliferative diabetic retinopathy (NPDR) patients (75 eyes) with type 2 diabetes mellitus (T2DM), including 28 patients (36 eyes) with diabetic macular edema (DME) and 27 patients (39 eyes) without DME, and 25 healthy subjects (47 eyes) were enrolled in this study. The following parameters of DR patients with and without DME were evaluated: the foveal avascular zone area (FAZ-a), FAZ perimeter (FAZ-p), FAZ circularity index (FAZ-CI), total subfoveal choroidal area (TCA), luminal area (LA), stromal area (SA), choroidal vascularity index (CVI), choriocapillaris flow area percentage, superficial capillary plexus (SCP), and deep capillary plexus (DCP).Results: SCP, DCP, and the percentage of choriocapillaris flow area were significantly different between DR patients with and without DME. The DR patients presented lower LA, CVI, and FAZ-CI compared to those of healthy controls (all p < 0.05). The percentage of choriocapillaris flow area in DR patients with and without DME was significantly lower than that in healthy controls (p < 0.05). SCP and DCP were significantly correlated with FAZ-a and FAZ-p but presented insignificant associations with FAZ-CI.Conclusions: Optical coherence tomography (OCT) and OCT angiography (OCTA) parameters, such as LA, CVI, FAZ-CI, and the percentage of choriocapillaris flow area, were reduced compared to those in controls, indicating that the microcirculations of the retina and choroid in the macular area were impaired in DR patients with DME and without DME.


  • Open Access

    Using the C-Read as a Portable Device to Evaluate Reading Ability in Young Chinese Adults: An Observational Study

    by Tian Cheng, Taikang Yao, Boxuan Xu, Wanwei Dai, Xuejiao Qin, Juan Ye, Lingge Suo, Chun Zhang

    We evaluated the reading characteristics of normal-sighted young adults using C-Read to provide baseline healthy population values. We also investigated the relationship between the National Eye Institute’s Visual Functioning Questionnaire (VFQ-25) score and reading ability, myopia, and hours of screen use, focusing on the extent to which these factors affect participants’ visual function and, ultimately, their vision-related quality of life (QoL). Overall, 207 young, healthy participants (414 eyes) aged 18–35 years were tested for reading speed using C-Read connected to a smartphone-based application between December 2022 and January 2023. Each participant received a VFQ-25 questionnaire to evaluate vision-related QoL. Data on daily e-screen usage hours were collected. Among the participants, 91 (44.0%) were women; their mean (SD) age was 22.45 (4.01) years. The mean (SD) reading acuity (RA) was 0.242 (0.124), 0.249 (0.120), and 0.193 (0.104) logarithmic minimum angle of resolution (logMAR) for the right, left, and both eyes, respectively. The mean (SD) maximum reading speed (MRS) was 171.65 (46.27), 168.59 (45.68), and 185.16 (44.93) words per minute (wpm) with the right, left, and both eyes, respectively. The mean (SD) critical print size (CPS) was 0.412 (0.647), 0.371 (0.229), and 0.419 (1.05) logMAR per the right, left, and both eyes, respectively. The RA and CPS were significantly different between sexes (p = 0.002 and p = 0.001). MRS was significantly different between the education level (p = 0.005) and myopia level groups (p = 0.010); however, it was not clear whether this difference was confounded by age. The myopic power in diopters significantly affected RA (coefficient, −0.012; 95% CI, −0.018 to −0.006; p = 0.001); screen time significantly affected MRS (coefficient, 0.019; 95% CI, 0.57 to 6.33; p = 0.019). RA (coefficient, −21.41; 95% CI, −33.74 to −9.08; p = 0.001) and duration of screen use (coefficient, -0.86; 95% CI, −1.29 to −0.43; p < 0.001) independently had a significantly negative correlation with VFQ-25 scores. Our findings provide a baseline value for C-Read in normal-sighted young adults. Refractive status significantly affected RA, while screen time significantly affected MRS. Interventions aimed at enhancing RA may have the potential to maximize vision-related QoL and enable older adults with impaired vision to achieve greater outcomes. Future, larger-scale, C-Read experiments will help provide newer, more optimal methods for the early diagnosis of visual impairment.


  • Open Access

    Vitrectomy for Complicated Retinal Detachment Without the Use of Perfluorocarbon Liquid: A Real-World Data and Retrospective Study

    by Ye Bai, Qi Song, Jing Liu, Qin-Xing Wu, Xue-Jiao Qin

    Introduction This study aimed to evaluate the effectiveness of vitrectomy without using perfluorocarbon liquid (PFCL) for the treatment of complicated retinal detachment (RD). Methods The utilisation of PFCL was calculated in four hospitals in 2020 and in one hospital every year from 2012 to 2020. A case series of 320 RD eyes treated with vitrectomy without the use of perfluorocarbon liquid (VWTPL) was followed up for 1–26 months. The rate of retinal reattachment (RR) and postoperative visual acuity (VA, LogMAR) was evaluated. Furthermore, factors influencing RR and VA were analysed. Results The overall utilisation of PFCL was 43.87% (42.74%, 45.83%, 62.39% and 4.5%). The annual utilisation was 46.94%, 20.43%, 46.73%, 47.41%, 20%, 17.24%, 7.60%, 10.67% and 4.49% from 2012 to 2020. The VA of 320 eyes improved from 1.96 ± 1.07 preoperatively to 1.43 ± 0.92 (LogMAR, p < 0.001) 1 week post-operation. In the follow-up of 1–26 months (median: 9 months), the primary and final RR was 87.37% and 95.56%, respectively. Age, uveitis, recurrent RD, the number of detached retinal quadrants, aPVR and preoperative VA were considered as the factors influencing postoperative VA. Moreover, preoperative VA and preoperative intraocular pressure were the factors influencing RR. Conclusion The utilisation of PFCL varies amongst hospitals with a highest percentage of 62.39%. VWTPL is safe and effective, thereby saving costs and preventing complications related to PFCL. Trial Registration ChiCTR-ORC-17014225.


  • Open Access

    Use of Mobile Apps for Visual Acuity Assessment: Systematic Review and Meta-analysis

    by Lingge Suo, Xianghan Ke, Di Zhang, Xuejiao Qin, Xuhao Chen, Ying Hong, Wanwei Dai, Defu Wu, Chun Zhang, Dongsong Zhang

    Background: Vision impairments (VIs) and blindness are major global public health issues. A visual acuity (VA) test is one of the most crucial standard psychophysical tests of visual function and has been widely used in a broad range of health care domains, especially in many clinical settings. In recent years, there has been increasing research on mobile app–based VA assessment designed to allow people to test their VA at any time and any location. Objective: The goal of the review was to assess the accuracy and reliability of using mobile VA measurement apps. Methods: We searched PubMed, Embase, Cochrane Library, and Google Scholar for relevant articles on mobile apps for VA assessment published between January 1, 2008, and July 1, 2020. Two researchers independently inspected and selected relevant studies. Eventually, we included 22 studies that assessed tablet or smartphone apps for VA measurement. We then analyzed sensitivity, specificity, and accuracy in the 6 papers we found through a meta-analysis. Results: Most of the 22 selected studies can be considered of high quality based on the Quality Assessment of Diagnostic Accuracy Studies–2. In a meta-analysis of 6 studies involving 24,284 participants, we categorized the studies based on the age groups of the study participants (ie, aged 3-5 years, aged 6-22 years, and aged 55 years and older), examiner (ie, professional and nonprofessional examiners), and the type of mobile devices (ie, smartphone, iPad). In the group aged 3 to 5 years, the pooled sensitivity for VA app tests versus clinical VA tests was 0.87 (95% CI 0.79-0.93; P=.39), and the pooled specificity was 0.78 (95% CI 0.70-0.85; P=.37). In the group aged 6 to 22 years, the pooled sensitivity for VA app tests versus clinical VA tests was 0.86 (95% CI 0.84-0.87; P<.001), and the pooled specificity for VA app tests versus clinical VA tests was 0.91 (95% CI 0.90-0.91; P=.27). In the group aged 55 years and older, the pooled sensitivity for VA app tests versus clinical VA tests was 0.85 (95% CI 0.55-0.98), and the pooled specificity for VA app tests versus clinical VA tests was 0.98 (95% CI 0.95-0.99). We found that the nonprofessional examiner group (AUC 0.93) had higher accuracy than the professional examiner group (AUC 0.87). In the iPad-based group, the pooled sensitivity for VA app tests versus clinical VA tests was 0.86, and the pooled specificity was 0.79. In the smartphone-based group, the pooled sensitivity for VA app tests versus clinical VA tests was 0.86 (P<.001), and the pooled specificity for VA app tests versus clinical VA tests was 0.91 (P<.001). Conclusions: In this study, we conducted a comprehensive review of the research on existing mobile apps for VA tests to investigate their diagnostic value and limitations. Evidence gained from this study suggests that mobile app–based VA tests can be useful for on-demand VI detection.