Nick Ferris
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Nick Ferris has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Chris Fox
University of Exeter, Exeter, Devon, United Kingdom
1 shared publication - Farshad Foroudi
Department of Radiation Oncology ONJ Centre, Austin Health Heidelberg Victoria Australia
1 shared publication - Keen Hun Tai
Department of Radiation Oncology, Peter MacCallum Cancer Centre, Melbourne, Australia
1 shared publication - Kim Dang
Radiation Therapy Services, Peter MacCallum Cancer Centre, Melbourne, Australia
1 shared publication - Mathias Bressel
Sir Peter MacCallum Department of Oncology, University of Melbourne, Melbourne 3000, Australia
1 shared publication - Noelene Bergen
Department of Cancer Imaging, Peter MacCallum Cancer Centre, Melbourne, Australia
1 shared publication
Latest Publications
- Open Access
- 8 August 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 1-8
Seminal vesicle intrafraction motion analysed with cinematic magnetic resonance imaging
This study analyses seminal vesicle displacement relative to the prostate and in relation to treatment time. A group of eleven patients undergoing prostate cancer radiotherapy were imaged with a continuous 3 T cine-MRI in the standard treatment setup position. Four images were recorded every 4 seconds for 15 minutes in the sagittal plane and every 6.5 seconds for 12 minutes in the coronal plane. The prostate gland and seminal vesicles were contoured on each MRI image. The coordinates of the centroid of the prostate and seminal vesicles on each image was analysed for displacement against time. Displacements between the 2.5 percentile and 97.5 percentile (i.e. the 2.5% trimmed range) for prostate and seminal vesicle centroid displacements were measured for 3, 5, 10 and 15 minutes time intervals in the anterior-posterior (AP), left-right (LR) and superior-inferior (SI) directions. Real time prostate and seminal vesicle displacement was compared for individual patients. The 2.5% trimmed range for 3, 5, 10 and 15 minutes for the seminal vesicle centroids in the SI direction measured 4.7 mm; 5.8 mm; 6.5 mm and 7.2 mm respectively. In the AP direction, it was 4.0 mm, 4.5 mm, 6.5 mm, and 7.0 mm. In the LR direction for 3, 5 and 10 minutes; for the left seminal vesicle, it was 2.7 mm, 2.8 mm, 3.4 mm and for the right seminal vesicle, it was 3.4 mm, 3.3 mm, and 3.4 mm. The correlation between the real-time prostate and seminal vesicle displacement varied substantially between patients indicating that the relationship between prostate displacement and seminal vesicles displacement is patient specific with the majority of the patients not having a strong relationship. Our study shows that seminal vesicle motion increases with treatment time, and that the prostate and seminal vesicle centroids do not move in unison in real time, and that an additional margin is required for independent seminal vesicle motion if treatment localisation is to the prostate.
- 8 August 2014
- Published by Springer Nature in Radiation Oncology
- Vol. 9 (1) , 1-8
Open AccessSeminal vesicle intrafraction motion analysed with cinematic magnetic resonance imaging
This study analyses seminal vesicle displacement relative to the prostate and in relation to treatment time. A group of eleven patients undergoing prostate cancer radiotherapy were imaged with a continuous 3 T cine-MRI in the standard treatment setup position. Four images were recorded every 4 seconds for 15 minutes in the sagittal plane and every 6.5 seconds for 12 minutes in the coronal plane. The prostate gland and seminal vesicles were contoured on each MRI image. The coordinates of the centroid of the prostate and seminal vesicles on each image was analysed for displacement against time. Displacements between the 2.5 percentile and 97.5 percentile (i.e. the 2.5% trimmed range) for prostate and seminal vesicle centroid displacements were measured for 3, 5, 10 and 15 minutes time intervals in the anterior-posterior (AP), left-right (LR) and superior-inferior (SI) directions. Real time prostate and seminal vesicle displacement was compared for individual patients. The 2.5% trimmed range for 3, 5, 10 and 15 minutes for the seminal vesicle centroids in the SI direction measured 4.7 mm; 5.8 mm; 6.5 mm and 7.2 mm respectively. In the AP direction, it was 4.0 mm, 4.5 mm, 6.5 mm, and 7.0 mm. In the LR direction for 3, 5 and 10 minutes; for the left seminal vesicle, it was 2.7 mm, 2.8 mm, 3.4 mm and for the right seminal vesicle, it was 3.4 mm, 3.3 mm, and 3.4 mm. The correlation between the real-time prostate and seminal vesicle displacement varied substantially between patients indicating that the relationship between prostate displacement and seminal vesicles displacement is patient specific with the majority of the patients not having a strong relationship. Our study shows that seminal vesicle motion increases with treatment time, and that the prostate and seminal vesicle centroids do not move in unison in real time, and that an additional margin is required for independent seminal vesicle motion if treatment localisation is to the prostate.