Young-Chan Jeon
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Young-Chan Jeon has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
Mi-Jung Yun
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
7 shared publicationsChang-Mo Jeong
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
6 shared publications- Jung-Bo Huh
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan 50612, Republic of Korea
6 shared publications - Chang-Mo Jeong
Department of Prosthodontics, Dental Research Institute, Dental and Life Science Institute, BK21 PLUS Project, School of Dentistry, Pusan National University, Yangsan 50612, Korea
4 shared publications - Mi-Jung Yun
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Republic of Korea
2 shared publications Sun-Nyo Kang
Department of Prosthodontics, School of Dentistry, Pusan National University, Yangsan, Korea
2 shared publications
Latest Publications
- Open Access
- 8 August 2017
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 18 (8) , 1725
The Effect of Reduced Graphene Oxide-Coated Biphasic Calcium Phosphate Bone Graft Material on Osteogenesis
This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be −14.43 mV, which formed a static electrostatic interaction. Cell viabilities were significantly diminished at higher concentrations of ≥100 μg/mL. The calvarial defects of 48 rats were implanted rGO-coated BCPs at a weight ratio of 2:1000 (rGO2), 4:1000 (rGO4), and 10:1000 (rGO10), repectively. BCP was used as a control group. The micro-CT and histological analysis were performed to evaluate new bone formation at 2 and 8 weeks after surgery. The results showed that the new bone volume (mm3) was significantly higher in the experimental groups than in the control group. Histological analysis showed that new bone areas (%) were significantly higher in the rGO2 and rGO10 than in the control, and significantly higher in rGO4 than in the rGO2 and rGO10. Conclusively, the rGO-coated BCP was found to be effective on osteogenesis and the concentration of the composite was an important factor.
- 8 August 2017
- Published by MDPI AG in International Journal of Molecular Sciences
- Vol. 18 (8) , 1725
Open AccessThe Effect of Reduced Graphene Oxide-Coated Biphasic Calcium Phosphate Bone Graft Material on Osteogenesis
This study was conducted to evaluate the effect of biphasic calcium phosphate (BCP) coated with reduced graphene oxide (rGO) as bone graft materials on bone regeneration. The rGO-coated BCP bone graft material was fabricatied by mixing rGO and BCP at various concentrations. The surface charge of rGO-coated BCP was measured to be −14.43 mV, which formed a static electrostatic interaction. Cell viabilities were significantly diminished at higher concentrations of ≥100 μg/mL. The calvarial defects of 48 rats were implanted rGO-coated BCPs at a weight ratio of 2:1000 (rGO2), 4:1000 (rGO4), and 10:1000 (rGO10), repectively. BCP was used as a control group. The micro-CT and histological analysis were performed to evaluate new bone formation at 2 and 8 weeks after surgery. The results showed that the new bone volume (mm3) was significantly higher in the experimental groups than in the control group. Histological analysis showed that new bone areas (%) were significantly higher in the rGO2 and rGO10 than in the control, and significantly higher in rGO4 than in the rGO2 and rGO10. Conclusively, the rGO-coated BCP was found to be effective on osteogenesis and the concentration of the composite was an important factor.
- Open Access
Comparative Efficacies of a 3D-Printed PCL/PLGA/β-TCP Membrane and a Titanium Membrane for Guided Bone Regeneration in Beagle Dogs
This study was conducted to evaluate the effects of a 3D-printed resorbable polycaprolactone/poly(lactic-co-glycolic acid)/β-tricalcium phosphate (PCL/PLGA/β-TCP) membrane on bone regeneration and osseointegration in areas surrounding implants and to compare results with those of a non-resorbable titanium mesh membrane. After preparation of PCL/PLGA/β-TCP membranes using extrusion-based 3D printing technology; mechanical tensile testing and in vitro cell proliferation testing were performed. Implant surgery and guided bone regeneration were performed randomly in three groups (a no membrane group, a titanium membrane group, and a PCL/PLGA/β-TCP membrane group (n = 8 per group)). Histological and histometric analyses were conducted to evaluate effects on bone regeneration and osseointegration. Using the results of mechanical testing; a PCL/PLGA/β-TCP ratio of 2:6:2 was selected. The new bone areas (%) in buccal defects around implants were highest in the PCL/PLGA/β-TCP group and significantly higher than in the control group (p < 0.05). Bone-to-implant contact ratios (%) were also significantly higher in the PCL/PLGA/β-TCP and titanium groups than in the control group (p < 0.05). When the guided bone regeneration procedure was performed using the PCL/PLGA/β-TCP membrane; new bone formation around the implant and osseointegration were not inferior to those of the non-resorbable pre-formed titanium mesh membrane.
Open AccessComparative Efficacies of a 3D-Printed PCL/PLGA/β-TCP Membrane and a Titanium Membrane for Guided Bone Regeneration in Beagle Dogs
This study was conducted to evaluate the effects of a 3D-printed resorbable polycaprolactone/poly(lactic-co-glycolic acid)/β-tricalcium phosphate (PCL/PLGA/β-TCP) membrane on bone regeneration and osseointegration in areas surrounding implants and to compare results with those of a non-resorbable titanium mesh membrane. After preparation of PCL/PLGA/β-TCP membranes using extrusion-based 3D printing technology; mechanical tensile testing and in vitro cell proliferation testing were performed. Implant surgery and guided bone regeneration were performed randomly in three groups (a no membrane group, a titanium membrane group, and a PCL/PLGA/β-TCP membrane group (n = 8 per group)). Histological and histometric analyses were conducted to evaluate effects on bone regeneration and osseointegration. Using the results of mechanical testing; a PCL/PLGA/β-TCP ratio of 2:6:2 was selected. The new bone areas (%) in buccal defects around implants were highest in the PCL/PLGA/β-TCP group and significantly higher than in the control group (p < 0.05). Bone-to-implant contact ratios (%) were also significantly higher in the PCL/PLGA/β-TCP and titanium groups than in the control group (p < 0.05). When the guided bone regeneration procedure was performed using the PCL/PLGA/β-TCP membrane; new bone formation around the implant and osseointegration were not inferior to those of the non-resorbable pre-formed titanium mesh membrane.
- Open Access
Comparative Shear-Bond Strength of Six Dental Self-Adhesive Resin Cements to Zirconia
This study compared shear bond strength (SBS) of six self-adhesive resin cements (SARC) and one resin-modified glass ionomer cement (RMGIC) to zirconia before and after thermocycling. The cylinder shape (Φ 2.35 mm × 3 mm) of six SARCs (G-CEM LinkAce (GLA), Maxcem Elite (MAX), Clearfil SA Luting (CSL), PermaCem 2.0 (PM2), Rely-X U200 (RXU), Smartcem 2 (SC2)) were bonded to the top surface of the zirconia specimens with light-curing. RMGIC (Fujicem (FJC)) was bonded to the specimens with self-curing. The shear bond strength of all cemented specimens was measured with universal testing machine. Half of the specimens were thermocycled 5000 times before shear bonding strength testing. Fractured surfaces were examined with a field-emission SEM (10,000×) and analyzed by energy dispersive x-ray analysis. MAX, PM2, SC2 group without thermocycling and GLA, MAX, PM2 group with thermocycling showed adhesive failure, but GLA, CSL, RXU, FJC group without thermocycling and SLC, RXU, SC2, FJC group with thermocycling indicated cohesive failure. Within the limitation of this study, All of SARCs except MAX demonstrated higher bond strength than that of RMGIC regardless of thermocycling. Also, SARC containing MDP monomers (CSL) retained better bonds than other cements.
Open AccessComparative Shear-Bond Strength of Six Dental Self-Adhesive Resin Cements to Zirconia
This study compared shear bond strength (SBS) of six self-adhesive resin cements (SARC) and one resin-modified glass ionomer cement (RMGIC) to zirconia before and after thermocycling. The cylinder shape (Φ 2.35 mm × 3 mm) of six SARCs (G-CEM LinkAce (GLA), Maxcem Elite (MAX), Clearfil SA Luting (CSL), PermaCem 2.0 (PM2), Rely-X U200 (RXU), Smartcem 2 (SC2)) were bonded to the top surface of the zirconia specimens with light-curing. RMGIC (Fujicem (FJC)) was bonded to the specimens with self-curing. The shear bond strength of all cemented specimens was measured with universal testing machine. Half of the specimens were thermocycled 5000 times before shear bonding strength testing. Fractured surfaces were examined with a field-emission SEM (10,000×) and analyzed by energy dispersive x-ray analysis. MAX, PM2, SC2 group without thermocycling and GLA, MAX, PM2 group with thermocycling showed adhesive failure, but GLA, CSL, RXU, FJC group without thermocycling and SLC, RXU, SC2, FJC group with thermocycling indicated cohesive failure. Within the limitation of this study, All of SARCs except MAX demonstrated higher bond strength than that of RMGIC regardless of thermocycling. Also, SARC containing MDP monomers (CSL) retained better bonds than other cements.
- Open Access
- 8 August 2014
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 12 (1) , 29
Enhancement of the killing effect of low-temperature plasma on Streptococcus mutans by combined treatment with gold nanoparticles
Recently, non-thermal atmospheric pressure plasma sources have been used for biomedical applications such as sterilization, cancer treatment, blood coagulation, and wound healing. Gold nanoparticles (gNPs) have unique optical properties and are useful for biomedical applications. Although low-temperature plasma has been shown to be effective in killing oral bacteria on agar plates, its bactericidal effect is negligible on the tooth surface. Therefore, we used 30-nm gNPs to enhance the killing effect of low-temperature plasma on human teeth.
- 8 August 2014
- Published by Springer Nature in Journal of Nanobiotechnology
- Vol. 12 (1) , 29
Open AccessEnhancement of the killing effect of low-temperature plasma on Streptococcus mutans by combined treatment with gold nanoparticles
Recently, non-thermal atmospheric pressure plasma sources have been used for biomedical applications such as sterilization, cancer treatment, blood coagulation, and wound healing. Gold nanoparticles (gNPs) have unique optical properties and are useful for biomedical applications. Although low-temperature plasma has been shown to be effective in killing oral bacteria on agar plates, its bactericidal effect is negligible on the tooth surface. Therefore, we used 30-nm gNPs to enhance the killing effect of low-temperature plasma on human teeth.
- Open Access
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 51 (2) , 82-89
Combined effects of rhBMP-2 and rhVEGF coated onto implants on osseointegration: pilot study
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 51 (2) , 82-89
Open AccessCombined effects of rhBMP-2 and rhVEGF coated onto implants on osseointegration: pilot study
- Open Access
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (1) , 2-8
Sterilization effect of atmospheric pressure non-thermal air plasma on dental instruments
Sung SJ, et al. J Adv Prosthodont. 2013 Feb;5(1):2-8. http://dx.doi.org/10.4047/jap.2013.5.1.2
- 1 January 2013
- Published by The Korean Academy of Prosthodontics in The Journal of Advanced Prosthodontics
- Vol. 5 (1) , 2-8
Open AccessSterilization effect of atmospheric pressure non-thermal air plasma on dental instruments
Sung SJ, et al. J Adv Prosthodont. 2013 Feb;5(1):2-8. http://dx.doi.org/10.4047/jap.2013.5.1.2
- Open Access
- 1 January 2012
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 50 (1) , 21-28
Effects of implant collar design on marginal bone and soft tissue
- 1 January 2012
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 50 (1) , 21-28
Open AccessEffects of implant collar design on marginal bone and soft tissue
- Open Access
- 1 January 2011
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 49 (1) , 73-79
The effect of repeated firings on the color of zirconia-based all-ceramic system
- 1 January 2011
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 49 (1) , 73-79
Open AccessThe effect of repeated firings on the color of zirconia-based all-ceramic system
- Open Access
- 1 January 2009
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 47 (3) , 328-334
Effect of prosthetic designs and alveolar bone conditions on stress distribution in fixed partial dentures with pier abutments
Cho W, et al. J Korean Acad Prosthodont. 2009 Jul;47(3):328-334. http://dx.doi.org/10.4047/jkap.2009.47.3.328
- 1 January 2009
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 47 (3) , 328-334
Open AccessEffect of prosthetic designs and alveolar bone conditions on stress distribution in fixed partial dentures with pier abutments
Cho W, et al. J Korean Acad Prosthodont. 2009 Jul;47(3):328-334. http://dx.doi.org/10.4047/jkap.2009.47.3.328
- Open Access
- 1 January 2009
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 47 (3) , 312-319
A study on the shear bond strengths of veneering ceramics to the colored zirconia core
Kang SN, et al. J Korean Acad Prosthodont. 2009 Jul;47(3):312-319. http://dx.doi.org/10.4047/jkap.2009.47.3.312
- 1 January 2009
- Published by The Korean Academy of Prosthodontics in The Journal of Korean Academy of Prosthodontics
- Vol. 47 (3) , 312-319
Open AccessA study on the shear bond strengths of veneering ceramics to the colored zirconia core
Kang SN, et al. J Korean Acad Prosthodont. 2009 Jul;47(3):312-319. http://dx.doi.org/10.4047/jkap.2009.47.3.312