AKAdil Karadag

Adil Karadag

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Adil Karadag has a total of 11 co-authors. Here are the top co-authors by number of shared publications:

  • Akif Koray Guney

    Department of Medical Microbiology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Turkey

    1 shared publication
  • Asuman Birinci

    Department of Medical Microbiology, Faculty of Medicine, Ondokuz Mayıs University, 55139 Samsun, Turkey

    1 shared publication
  • Cafer Eroglu

    Department of Medical Microbiology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Turkey

    1 shared publication
  • Egemen Usta

    Department of Medical Microbiology, Faculty of Medicine, Ondokuz Mayıs University, Samsun, Turkey

    1 shared publication
  • Hakan Odabasi

    Department of Medical Microbiology, University of Health Sciences, Sancaktepe Sehit Ilhan Varank Training and Research Hospital, Sancaktepe, 34785 Istanbul, Türkiye

    1 shared publication
  • Kemal Bilgin

    Department of Medical Services and Techniques, Vacational Higher School of Health Services, Samsun, Turkey

    1 shared publication

Latest Publications

  • Open Access

    In vitro antimicrobial activity of Medilox® super-oxidized water

    by Murat Gunaydin, Saban Esen, Adil Karadag, Nevzat Unal, Keramettin Yanik, Hakan Odabasi, Asuman Birinci

    Super-oxidized water is one of the broad spectrum disinfectants, which was introduced recently. There are many researches to find reliable chemicals which are effective, inexpensive, easy to obtain and use, and effective for disinfection of microorganisms leading hospital infections. Antimicrobial activity of super-oxidized water is promising. The aim of this study was to investigate the in-vitro antimicrobial activity of different concentrations of Medilox® super-oxidized water that is approved by the Food and Drug Administration (FDA) as high level disinfectant. In this study, super-oxidized water obtained from Medilox® [Soosan E & C, Korea] device, which had been already installed in our hospital, was used. Antimicrobial activities of different concentrations of super-oxidized water (1/1, 1/2, 1/5, 1/10, 1/20, 1/50, 1/100) at different exposure times (1, 2, 5, 10, 30 min) against six ATCC strains, eight antibiotic resistant bacteria, yeasts and molds were evaluated using qualitative suspension test. Dey-Engley Neutralizing Broth [Sigma-Aldrich, USA] was used as neutralizing agent. Medilox® was found to be effective against all standard strains (Acinetobacter baumannii 19606, Escherichia coli 25922, Enterococcus faecalis 29212, Klebsiella pneumoniae 254988, Pseudomonas aeruginosa 27853, Staphylococcus aureus 29213), all clinical isolates (Acinetobacter baumannii, Escherichia coli, vancomycin-resistant Enterococcus faecium, Klebsiella pneumoniae, Pseudomonas aeruginosa, methicillin-resistant Staphylococcus aureus, Bacillus subtilis, Myroides spp.), and all yeastsat 1/1 dilution in ≥1 minute. It was found to be effective on Aspergillus flavus at 1/1 dilution in ≥2 minutes and on certain molds in ≥5 minutes. Medilox® super-oxidized water is a broad spectrum, on-site producible disinfectant, which is effective on bacteria and fungi and can be used for the control of nosocomial infection.


  • Comparison of Culture, Real-Time DNA Amplification Assay and Ehrlich-Ziehl-Neelsen for Detection of Mycobacterium tuberculosis

    by Adil Karadag, Egemen Usta, Kemal Bilgin, Akif Koray Guney, Cafer Eroglu, Murat Gunaydin

    Mycobacterium tuberculosis is still a substantial health problem universally. Although culture is the gold standard method, reliable, rapid and new methods are required for effective struggle with disease. We retrospectively compared the results of Ehrlich-Ziehl-Neelsen (EZN) stain and real-time DNA amplification assay (BD ProbeTec ET system) with culture. Retrospective study. A total of 703 samples, 182 pulmonary and 521 extra pulmonary, collected from 630 patients between May 2008 and February 2011 were evaluated. Culture was considered the gold standard. For pulmonary specimens, sensitivity, specificity, positive predictive and negative predictive values of BD ProbeTec ET and EZN were calculated to be 100%, 98.8%, 87.5%, 100% and 71.4%, 98.8%, 83.3%, 97.6%, respectively. For extra pulmonary specimens, sensitivity, specificity, positive predictive and negative predictive values of BD ProbeTec ET and EZN were calculated to be 80%, 98.7%, 76.9%, 98.9% and 24%, 98.3%, 42.8%, 96.2%, respectively. According to these results, we suggest that the BD ProbeTec ET system is more reliable than EZN. In addition, the BD ProbeTec ET system produces faster results. Based upon these results, we consider that the BD ProbeTec ET system may be employed in the diagnosis of M. tuberculosis.