ALAshley M. Lee

Ashley M. Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article

Previous Organizations / Institutes

The organizations / institutes from the scholar's other articles in the past ten years


Ashley M. Lee has a total of 32 co-authors. Here are the top co-authors by number of shared publications:


Latest Publications

  • Open Access

    Effect of the 2010 task force criteria on reclassification of cardiovascular magnetic resonance criteria for arrhythmogenic right ventricular cardiomyopathy

    by Ting Liu, Amit Pursnani, Umesh C Sharma, Yongkasem Vorasettakarnkij, Daniel Verdini, Peerawut Deeprasertkul, Ashley M Lee, Heidi Lumish, Manavjot S Sidhu, Hector Medina, et al.


  • Coronary computed tomography angiography at 140 kV versus 120 kV: assessment of image quality and radiation exposure in overweight and moderately obese patients

    by Ashley M Lee, Leif-Christopher Engel, Gladwin C Hui, Gary Liew, Maros Ferencik, Manavjot S Sidhu, Udo Hoffmann, Brian B Ghoshhajra

    Background: Although a tube potential of 140 kV is available on most computed tomography (CT) scanners, its incremental diagnostic value versus 120 kV has been controversial. Purpose: To retrospectively evaluate the image quality and radiation exposure of cardiac computed tomography angiography (CCTA) performed at 140 kV in comparison to CCTA at 120 kV in overweight and moderately obese patients. Material and Methods: Eighty-eight patients who were referred for CCTA between January 2010 and May 2012 were included. Forty-four patients who were overweight or moderately obese (body mass index [BMI], 25–35 kg/m2) underwent CCTA with dual-source CT (DSCT) scanner at 140 kV. Forty-four match controls who underwent CCTA with DSCT at 120 kV were identified per BMI, average heart rate, scan indication, and scan acquisition mode. All scans were performed per routine protocols with direct physician supervision. Quantitative image metrics (CT attenuation, image noise, contrast-to-noise ratio [CNR], and signal-to-noise ratio [SNR] of left main [LM] and proximal right coronary artery [RCA]) were assessed. Effective radiation dose was compared between the two groups. Results: Overall, all scans were diagnostic without any non-evaluable coronary segment per clinical report. 140 kV had a lower attenuation and image noise versus 120 kV ( P < 0.01). Both SNR and CNR of proximal coronary arteries were similar between 140 kV and 120 kV (SNR, LM P = 0.93, RCA P = 0.62; CNR, LM P = 0.57, RCA P = 0.77). 140 kV was associated with a 35.3% increase in effective radiation dose as compared with 120 kV (5.1 [3.6–8.2] vs. 3.3 [2.0–5.1] mSv, respectively; P < 0.01). Conclusion: 140 kV CCTA resulted in similar image quality but a higher effective radiation dose in comparison to 120 kV CCTA. Therefore, in overweight and moderately obese patients, a tube potential of 120 kV may be sufficient for CCTA with diagnostic image quality.


  • Automatic Extraction of Comprehensive Cardiac CT Angiography Parameters: A Novel Program with High Accuracy and Efficiency

    by Ashley M. Lee, Brian B. Ghoshhajra

    We tested the accuracy and efficiency of a novel automated program capable of extracting 15 cardiac computed tomography angiography (CTA) parameters from clinical CTA reports. Five hundred cardiac CTA reports were retrospectively collected and processed. All reports were pre-populated with a structured template per guideline. The program extracted 15 parameters with high accuracy (97.3 %) and efficiency (84 s). This program may be used at other institutions with similar accuracy if its report format follows the Society of Cardiovascular Computed Tomography (SCCT) guideline recommendation.


  • A GPS Map for Pulmonary Hypertension: A Review of Imaging Modalities

    by Jinghui Li, Ashley Lee, Yingsheng Cheng

    Pulmonary hypertension (PH) is a lethal disease with a prevalence of 10-20 % in the general population. The current gold standard diagnosis approach is right heart catheterization, directly detecting pulmonary artery pressure. Imaging for PH patients plays an important role in the etiological diagnosis and evaluation of right heart (RV) function, which is a key determinant of morbidity and mortality in PH patients. Currently, echocardiography is the first-line imaging modality for screening PH and evaluating RV function. CMRI is the gold standard method to evaluate RV function. MDCT, radionuclide ventriculography and pulmonary angiography are mostly used in the differential diagnosis of the cause of PH. In this review article, we also mention several newly studied imaging modalities, such as three-dimensional echocardiography, intravascular ultrasound (IVUS) and optical coherence tomography (OCT), which showed promise for early diagnosis of PH.


  • Radiation Dose Reduction in Pediatric Cardiac Computed Tomography: Experience from a Tertiary Medical Center

    by Brian B. Ghoshhajra, Ashley M. Lee, Leif-Christopher Engel, Csilla Celeng, Mannudeep K. Kalra, Thomas J. Brady, Udo Hoffmann, Sjirk J. Westra, Suhny Abbara

    Cardiac CT angiography (cCTA) has become an established method for the assessment of congenital heart disease. However, the potential harmful effects of ionizing radiation must be considered, particularly in younger, more radiosensitive patients. In this study, we sought to assess the temporal change in radiation doses from pediatric cCTA during an 8-year period at a tertiary medical center. This retrospective study included all patients ≤18 years old who were referred to electrocardiography (ECG)-gated cCTA for the assessment of congenital heart disease or inflammatory disease (Kawasaki disease) from November 2004 to September 2012. During the study period, 95 patients were scanned using 3 different scanner models—64-slice multidetector CT (64-MDCT) and first- (64-DSCT) and second-generation (128-DSCT) dual-source CT—and 3 scan protocols—retrospective ECG-gated helical scanning (RG), prospective ECG-triggered axial scanning (PT), or prospective ECG-triggered high-pitch helical scanning (HPH). Effective dose (ED) was calculated with the dose length product method with a conversion factor (k) adjusted for age. ED was then compared among scan protocols. Image quality was extracted from clinical cCTA reports when available. Overall, 94 % of scans were diagnostic (80 % for 64-slice MDCT, 93 % for 64-slice DSCT, and 97 % for 128-slice DSCT).With 128-DSCT, median ED (1.0 [range 0.6–2.0] mSv) decreased by 85.8 % and 66.8 % compared with 64-MDCT (6.8 [range 2.9–13.6] mSv) and 64-DSCT (2.9 [range 0.9–4.1] mSv), respectively. With HPH, median ED (0.9 [range 0.6–1.8] mSv) decreased by 59.4 % and 85.4 % compared with PT (2.2 [range 0.9–3.4] mSv) and RG (6.1 [range 2.5–10.6] mSv). cCTA can now be obtained at very low radiation doses in pediatric patients using the latest dual-source CT technology in combination with prospective ECG-triggered HPH acquisition.


  • Open Access

    Feasibility of aortic valve assessment with low dose prospectively triggered adaptive systolic (PTAS) cardiac computed tomography angiography

    by Ashley M Lee, Jonathan Beaudoin, Wai-Ee Thai, Bryan Wai, Gladwin C Hui, Manavjot S Sidhu, Leif-Christopher Engel, Suhny Abbara, Udo Hoffmann, Brian B Ghoshhajra

    Cardiac computed tomography angiography (CTA) is feasible for aortic valve evaluation, but retrospective gated protocols required high radiation doses for aortic valve assessment. A prospectively triggered adaptive systolic (PTAS) cardiac CT protocol was recently described in arrhythmia using second-generation dual-source CT. In this study, we sought to evaluate the feasibility of PTAS CTA to assess the aortic valve at a low radiation dose.