Joseph Rice
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Research Subjects
Joseph Rice has a total of 21 co-authors. Here are the top co-authors by number of shared publications:
- B. Carol Johnson
National Institute of Standards and Technology
5 shared publications - Eric L. Shirley
National Institute of Standards and Technology
2 shared publications - James J. Butler
NASA Goddard Space Flight Center, Greenbelt, MD 20771, USA
2 shared publications A. Abtahi
1 shared publicationC. J. Donlon
1 shared publication- Changyong Cao
Center for Satellite Applications and Research (STAR), National Environmental Satellite, Data, and Information Service (NESDIS), National Oceanic and Atmospheric Administration (NOAA), College Park, MD 20740, USA
1 shared publication
Latest Publications
- 1 June 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 235-55
Optical Passive Sensor Calibration for Satellite Remote Sensing and the Legacy of NOAA and NIST Cooperation
This paper traces the cooperative efforts of scientists at the National Oceanic and Atmospheric Administration (NOAA) and the National Institute of Standards and Technology (NIST) to improve the calibration of operational satellite sensors for remote sensing of the Earth's land, atmosphere and oceans. It gives a chronological perspective of the NOAA satellite program and the interactions between the two agencies' scientists to address pre-launch calibration and issues of sensor performance on orbit. The drive to improve accuracy of measurements has had a new impetus in recent years because of the need for improved weather prediction and climate monitoring. The highlights of this cooperation and strategies to achieve SI-traceability and improve accuracy for optical satellite sensor data are summarized.
- 1 June 2014
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 119, 235-55
Optical Passive Sensor Calibration for Satellite Remote Sensing and the Legacy of NOAA and NIST Cooperation
This paper traces the cooperative efforts of scientists at the National Oceanic and Atmospheric Administration (NOAA) and the National Institute of Standards and Technology (NIST) to improve the calibration of operational satellite sensors for remote sensing of the Earth's land, atmosphere and oceans. It gives a chronological perspective of the NOAA satellite program and the interactions between the two agencies' scientists to address pre-launch calibration and issues of sensor performance on orbit. The drive to improve accuracy of measurements has had a new impetus in recent years because of the need for improved weather prediction and climate monitoring. The highlights of this cooperation and strategies to achieve SI-traceability and improve accuracy for optical satellite sensor data are summarized.
- 1 March 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (2) , 621-646
Best practice guidelines for pre-launch characterization and calibration of instruments for passive optical remote sensing
The pre-launch characterization and calibration of remote sensing instruments should be planned and carried out in conjunction with their design and development to meet the mission requirements. The onboard calibrators such as blackbodies and the sensors such as spectral radiometers should be characterized and calibrated using SI traceable standards. In the case of earth remote sensing, this allows inter-comparison and intercalibration of different sensors in space to create global time series of climate records of high accuracy where some inevitable data gaps can be easily bridged. The recommended best practice guidelines for this pre-launch effort is presented based on experience gained at National Institute of Standards and Technology (NIST), National Aeronautics and Space Administration (NASA) and National Oceanic and Atmospheric Administration (NOAA) programs over the past two decades. The currently available radiometric standards and calibration facilities at NIST serving the remote sensing community are described. Examples of best practice calibrations and intercomparisons to build SI (international System of Units) traceable uncertainty budget in the instrumentation used for preflight satellite sensor calibration and validation are presented.
- 1 March 2011
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 116 (2) , 621-646
Best practice guidelines for pre-launch characterization and calibration of instruments for passive optical remote sensing
The pre-launch characterization and calibration of remote sensing instruments should be planned and carried out in conjunction with their design and development to meet the mission requirements. The onboard calibrators such as blackbodies and the sensors such as spectral radiometers should be characterized and calibrated using SI traceable standards. In the case of earth remote sensing, this allows inter-comparison and intercalibration of different sensors in space to create global time series of climate records of high accuracy where some inevitable data gaps can be easily bridged. The recommended best practice guidelines for this pre-launch effort is presented based on experience gained at National Institute of Standards and Technology (NIST), National Aeronautics and Space Administration (NASA) and National Oceanic and Atmospheric Administration (NOAA) programs over the past two decades. The currently available radiometric standards and calibration facilities at NIST serving the remote sensing community are described. Examples of best practice calibrations and intercomparisons to build SI (international System of Units) traceable uncertainty budget in the instrumentation used for preflight satellite sensor calibration and validation are presented.
- 1 July 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (4) , 187-203
Sources of Differences in On-Orbital Total Solar Irradiance Measurements and Description of a Proposed Laboratory Intercomparison
There is a 5 W/m2 (about 0.35 %) difference between current on-orbit Total Solar Irradiance (TSI) measurements. On 18–20 July 2005, a workshop was held at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland that focused on understanding possible reasons for this difference, through an examination of the instrument designs, calibration approaches, and appropriate measurement equations. The instruments studied in that workshop included the Active Cavity Radiometer Irradiance Monitor III (ACRIM III) on the Active Cavity Radiometer Irradiance Monitor SATellite (ACRIMSAT), the Total Irradiance Monitor (TIM) on the Solar Radiation and Climate Experiment (SORCE), the Variability of solar IRradiance and Gravity Oscillations (VIRGO) on the Solar and Heliospheric Observatory (SOHO), and the Earth Radiation Budget Experiment (ERBE) on the Earth Radiation Budget Satellite (ERBS). Presentations for each instrument included descriptions of its design, its measurement equation and uncertainty budget, and the methods used to assess on-orbit degradation. The workshop also included a session on satellite- and ground-based instrument comparisons and a session on laboratory-based comparisons and the application of new laboratory comparison techniques. The workshop has led to investigations of the effects of diffraction and of aperture area measurements on the differences between instruments. In addition, a laboratory-based instrument comparison is proposed that uses optical power measurements (with lasers that underfill the apertures of the TSI instruments), irradiance measurements (with lasers that overfill the apertures of the TSI instrument), and a cryogenic electrical substitution radiometer as a standard for comparing the instruments. A summary of the workshop and an overview of the proposed research efforts are presented here.
- 1 July 2008
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 113 (4) , 187-203
Sources of Differences in On-Orbital Total Solar Irradiance Measurements and Description of a Proposed Laboratory Intercomparison
There is a 5 W/m2 (about 0.35 %) difference between current on-orbit Total Solar Irradiance (TSI) measurements. On 18–20 July 2005, a workshop was held at the National Institute of Standards and Technology (NIST) in Gaithersburg, Maryland that focused on understanding possible reasons for this difference, through an examination of the instrument designs, calibration approaches, and appropriate measurement equations. The instruments studied in that workshop included the Active Cavity Radiometer Irradiance Monitor III (ACRIM III) on the Active Cavity Radiometer Irradiance Monitor SATellite (ACRIMSAT), the Total Irradiance Monitor (TIM) on the Solar Radiation and Climate Experiment (SORCE), the Variability of solar IRradiance and Gravity Oscillations (VIRGO) on the Solar and Heliospheric Observatory (SOHO), and the Earth Radiation Budget Experiment (ERBE) on the Earth Radiation Budget Satellite (ERBS). Presentations for each instrument included descriptions of its design, its measurement equation and uncertainty budget, and the methods used to assess on-orbit degradation. The workshop also included a session on satellite- and ground-based instrument comparisons and a session on laboratory-based comparisons and the application of new laboratory comparison techniques. The workshop has led to investigations of the effects of diffraction and of aperture area measurements on the differences between instruments. In addition, a laboratory-based instrument comparison is proposed that uses optical power measurements (with lasers that underfill the apertures of the TSI instruments), irradiance measurements (with lasers that overfill the apertures of the TSI instrument), and a cryogenic electrical substitution radiometer as a standard for comparing the instruments. A summary of the workshop and an overview of the proposed research efforts are presented here.
- 1 September 2006
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 111 (5) , 401-10
Spectrally Tunable Sources for Advanced Radiometric Applications
A common radiometric platform for the development of application-specific metrics to quantify the performance of sensors and systems is described. Using this platform, sensor and system performance may be quantified in terms of the accuracy of measurements of standardized sets of source distributions. The prototype platform consists of spectrally programmable light sources that can generate complex spectral distributions in the ultraviolet, visible and short-wave infrared regions for radiometric, photometric and colorimetric applications. In essence, the programmable spectral source is a radiometric platform for advanced instrument characterization and calibration that can also serve as a basis for algorithm testing and instrument comparison.
- 1 September 2006
- Published by National Institute of Standards and Technology (NIST) in Journal of Research of the National Institute of Standards and Technology
- Vol. 111 (5) , 401-10
Spectrally Tunable Sources for Advanced Radiometric Applications
A common radiometric platform for the development of application-specific metrics to quantify the performance of sensors and systems is described. Using this platform, sensor and system performance may be quantified in terms of the accuracy of measurements of standardized sets of source distributions. The prototype platform consists of spectrally programmable light sources that can generate complex spectral distributions in the ultraviolet, visible and short-wave infrared regions for radiometric, photometric and colorimetric applications. In essence, the programmable spectral source is a radiometric platform for advanced instrument characterization and calibration that can also serve as a basis for algorithm testing and instrument comparison.
- 1 February 2004
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 21 (2) , 258-267
The Miami2001 Infrared Radiometer Calibration and Intercomparison. Part I: Laboratory Characterization of Blackbody Targets
The second calibration and intercomparison of infrared radiometers (Miami2001) was held at the University of Miami's Rosenstiel School of Marine and Atmospheric Science (RSMAS) during May–June 2001. The participants were from several groups involved with the validation of skin sea surface temperatures and land surface temperatures derived from the measurements of imaging radiometers on earth observation satellites. These satellite instruments include those currently on operational satellites and others that will be launched within two years following the workshop. There were two experimental campaigns carried out during the 1-week workshop: a set of measurements made by a variety of ship-based radiometers on board the Research Vessel F. G. Walton Smith in Gulf Stream waters off the eastern coast of Florida, and a set of laboratory measurements of typical external blackbodies used to calibrate these ship-based radiometers. This paper reports on the results obtained from the laboratory characteriza... Abstract The second calibration and intercomparison of infrared radiometers (Miami2001) was held at the University of Miami's Rosenstiel School of Marine and Atmospheric Science (RSMAS) during May–June 2001. The participants were from several groups involved with the validation of skin sea surface temperatures and land surface temperatures derived from the measurements of imaging radiometers on earth observation satellites. These satellite instruments include those currently on operational satellites and others that will be launched within two years following the workshop. There were two experimental campaigns carried out during the 1-week workshop: a set of measurements made by a variety of ship-based radiometers on board the Research Vessel F. G. Walton Smith in Gulf Stream waters off the eastern coast of Florida, and a set of laboratory measurements of typical external blackbodies used to calibrate these ship-based radiometers. This paper reports on the results obtained from the laboratory characteriza...
- 1 February 2004
- Published by American Meteorological Society in Journal of Atmospheric and Oceanic Technology
- Vol. 21 (2) , 258-267
The Miami2001 Infrared Radiometer Calibration and Intercomparison. Part I: Laboratory Characterization of Blackbody Targets
The second calibration and intercomparison of infrared radiometers (Miami2001) was held at the University of Miami's Rosenstiel School of Marine and Atmospheric Science (RSMAS) during May–June 2001. The participants were from several groups involved with the validation of skin sea surface temperatures and land surface temperatures derived from the measurements of imaging radiometers on earth observation satellites. These satellite instruments include those currently on operational satellites and others that will be launched within two years following the workshop. There were two experimental campaigns carried out during the 1-week workshop: a set of measurements made by a variety of ship-based radiometers on board the Research Vessel F. G. Walton Smith in Gulf Stream waters off the eastern coast of Florida, and a set of laboratory measurements of typical external blackbodies used to calibrate these ship-based radiometers. This paper reports on the results obtained from the laboratory characteriza... Abstract The second calibration and intercomparison of infrared radiometers (Miami2001) was held at the University of Miami's Rosenstiel School of Marine and Atmospheric Science (RSMAS) during May–June 2001. The participants were from several groups involved with the validation of skin sea surface temperatures and land surface temperatures derived from the measurements of imaging radiometers on earth observation satellites. These satellite instruments include those currently on operational satellites and others that will be launched within two years following the workshop. There were two experimental campaigns carried out during the 1-week workshop: a set of measurements made by a variety of ship-based radiometers on board the Research Vessel F. G. Walton Smith in Gulf Stream waters off the eastern coast of Florida, and a set of laboratory measurements of typical external blackbodies used to calibrate these ship-based radiometers. This paper reports on the results obtained from the laboratory characteriza...