DLDemei Lee

Demei Lee

*This is an algorithmically generated author record based on publicly available information.

Current Organizations / Institutes

The organizations/institutes from the scholar's latest article


Demei Lee has a total of 53 co-authors. Here are the top co-authors by number of shared publications:

  • Shih-Jung Liu

    Department of Mechanical Engineering, Chang Gung University, Taoyuan, 33302, Taiwan

    9 shared publications
  • Ching-Lung Tai

    Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital, Chang Gung University College of Medicine, Taoyuan, Taiwan

    7 shared publications
  • Po-Liang Lai

    Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan

    5 shared publications
  • Ming-Kai Hsieh

    Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan

    3 shared publications
  • Weng-Pin Chen

    Department of Mechanical Engineering, National Taipei University of Technology, Taipei, Taiwan

    3 shared publications
  • Yun-Da Li

    Department of Orthopaedic Surgery, Spine Section, Bone and Joint Research Center, Chang Gung Memorial Hospital and Chang Gung University College of Medicine, Taoyuan, Taiwan; Department of Orthopedic Surgery, New Taipei Municipal TuCheng Hospital (Built and Operated by Chang Gung Medical Foundation), New Taipei City, Taiwan

    3 shared publications

Latest Publications

  • Open Access

    The biomechanical impact of cement volume and filling pattern for augmented pedicle screws using various density testing blocks

    by Ming-Kai Hsieh, Weng-Pin Chen, De-Mei Lee, Yun-Da Li, Fu-Cheng Kao, Hao-Hsin Chiang, Tsung-Ting Tsai, Tsai-Sheng Fu, Po-Liang Lai, Ching-Lung Tai


  • Open Access

    Biomechanical insights into anterolateral vertebral screw fixation in osteoporotic spines: a comparative study of fixation methods and positions using porcine vertebrae

    by Ming-Kai Hsieh, Yun-Da Li, Weng-Pin Chen, De-Mei Lee, Ching-Lung Tai

    Combining oblique lumbar interbody fusion (OLIF) with posterior pedicle screw fixation (PPSF) has been proposed to reduce cage subsidence, especially in osteoporotic spines. Recently, anterolateral screw-rod fixation has gained interest as it allows direct pathology observation and avoids a posterior approach. However, controversies exist between anterolateral screw fixation systems and traditional PPSF due to variations in osteoporotic vertebral mineral density, screw fixation positions, and fixation methods (bicortical vs. unicortical). This study aimed to investigate the biomechanical impact of fixation position and method in osteoporotic spine. Seventy-two fresh‑frozen porcine vertebrae (L1–6) were decalcified using 0.5 M EDTA and divided into two groups based on fixation method: bicortical or unicortical. Six groups for each method were created according to the screw position in the lateral vertebral body, with six specimens in each group: anterior, central, and posterior in the middle body and para-endplate regions. Correlations among screw position, fixation method and axial pullout strength were analyzed. A 4-week decalcification process, bone mineral density in the porcine vertebrae decreased to approximately 48% (p < 0.05) of the original value, categorizing them as osteoporotic. Bicortical fixation showed significantly greater pullout forces than unicortical fixation, with differences ranging from 82 to 273%. Notably, central or posterior screws outperformed anterior screws in pullout strength. Bicortical fixation exhibited significantly greater pullout forces than unicortical fixation. We suggest positioning screws in the central or posterior region of the middle body with bicortical fixation in osteoporotic vertebrae.


  • Open Access

    Forcefully engaging rods into tulips with gap discrepancy leading to pedicle screw loosening—a biomechanical analysis using long porcine spine segments

    by Ming-Kai Hsieh, De-Mei Lee, Weng-Pin Chen, Yun-Da Li, Fu-Cheng Kao, Yue-Chen Lin, Tsung-Ting Tsai, Po-Liang Lai, Ching-Lung Tai


  • Open Access

    Biomechanical Evaluation of a Novel Expandable Vertebral Augmentation System Using Human Cadaveric Vertebrae

    by Ming-Kai Hsieh, Wen-Jer Chen, Mel S. Lee, Sheng-Yu Lin, Mu-Yi Liu, De-Mei Lee, Ching-Lung Tai

    Unacceptable sagittal alignment and cement leakage are major concerns of percutaneous vertebroplasty when treating patients with painful vertebral osteoporotic compression fractures. To maintain the restored vertebral height and reduce the reliance on cement as the major stabilizer, an expandable vertebral augment system (EVA®) made of titanium alloy consisting of a rigid tube encased by a barrel with an anterior expansion mechanism was developed. The aim of the current study was to determine whether this novel design is as effective as existing procedures in terms of height restoration and biomechanical performance. Eight osteoporotic vertebrae (T12-L3) confirmed by dual-energy X-ray absorptiometry from two fresh-frozen human cadavers (70- and 72-year-old females) were used. Twenty-five percent reduced anterior wedge vertebral compression fractures were created using a material testing machine. Four randomized specimens were augmented with EVA® (Chang Gu Biotechnology Co. Ltd., Taipei city, Taiwan), and another four randomized specimens were augmented with OsseoFix® (AlphaTec Spine Inc., Carlsbad, CA, USA). The implant size and cement volume were controlled. The anterior vertebral body height (VBH) ratio and pre/postaugmented ultimate strength and stiffness were measured and compared. The mean anterior VBH restoration ratio was 8.54% in the EVA® group and 8.26% in the OsseoFix® groups. A significant difference from augmentation was measured in both groups (p < 0.05), but there was no significant difference between the EVA® and OsseoFix® groups in anterior VBH restoration. The ultimate strengths of the EVA® and OsseoFix® groups were 6071.4 ± 352.6 N and 6262.9 ± 529.2 N, respectively, both of which were statistically significantly higher than that of the intact group (4589.9 ± 474.6 N) (p < 0.05). The stiffnesses of the EVA®, OsseoFix®, and intact groups were 1087.2 ± 176.9, 1154.9 ± 168.9, and 1637.3 ± 340.8 N/mm, respectively, indicating that the stiffness was significantly higher in the intact group than in both the EVA® and OsseoFix® groups (p < 0.05). No significant differences were observed between the two augmentation procedures in height restoration or ultimate strength and stiffness. This novel EVA® system showed comparable height restoration and biomechanical performance to those of existing implants for human cadaveric osteoporotic compression fractures. Potential advantages of preventing cement posterior leakage and promoting cement interdigitation are expected with this ameliorated design.


  • Open Access

    Biomechanical Comparison of Salvage Pedicle Screw Augmentations Using Different Biomaterials

    by Yun-Da Li, Ming-Kai Hsieh, De-Mei Lee, Yi-Jiun Lin, Tsung-Ting Tsai, Po-Liang Lai, Ching-Lung Tai

    Allograft bone particles, hydroxyapatite/β-hydroxyapatite-tricalcium phosphate (HA/β-TCP), calcium sulfate (CS), and polymethylmethacrylate (PMMA) bone cement are biomaterials clinically used to fill defective pedicles for pedicle screw augmentation. Few studies have systematically investigated the effects of various biomaterials utilized for salvage screw stabilization. The aim of this study was to evaluate the biomechanical properties of screws augmented with these four different materials and the effect of different pilot hole sizes and bone densities on screw fixation strength. Commercially available synthetic bones with three different densities (7.5 pcf, 15pcf, 30 pcf) simulating different degrees of bone density were utilized as substitutes for human bone. Two different pilot hole sizes (3.2 mm and 7.0 mm in diameter) were prepared on test blocks to simulate primary and revision pedicle screw fixation, respectively. Following separate specimen preparation with these four different filling biomaterials, a screw pullout test was conducted using a material test machine, and the average maximal screw pullout strength was compared among groups. The average maximal pullout strength of the materials, presented in descending order, was as follows: bone cement, calcium sulfate, HA/β-TCP, allograft bone chips and the control. In samples in both the 3.2 mm pilot-hole and 7.0 mm pilot-hole groups, the average maximal pullout strength of these four materials increased with increasing bone density. The average maximal pullout strength of the bone cement augmented salvage screw (7.0 mm) was apparently elevated in the 7.5 pcf test block. Salvage pedicle screw augmentation with allograft bone chips, HA/β-TCP, calcium sulfate, and bone cement are all feasible methods and can offer better pullout strength than materials in the non-augmentation group. Bone cement provides the most significantly augmented effect in each pilot hole size and bone density setting and could be considered preferentially to achieve larger initial stability during revision surgery, especially for bones with osteoporotic quality.


  • Open Access

    Bone Morphogenetic Protein-, Antimicrobial Agent-, and Analgesic-Incorporated Nanofibrous Scaffolds for the Therapy of Alveolar Clefts

    by Pang-Yun Chou, Demei Lee, Chi-Chang Weng, Ren-Chin Wu, Chien-Tun Liao, Shih-Jung Liu

    An alveolar cleft is a bone defect in the maxillary arch. Although the use of autologous iliac bone grafts to repair alveolar clefts is the preferred treatment method, donor-site morbidity remains a concern. In this study, we incorporated bone morphogenetic protein (BMP), an antimicrobial agent, and an analgesic into nanofibrous scaffolds for alveolar cleft therapy. Three-dimensional (3D) printing and coaxial electrospinning techniques were used to fabricate the scaffolds. BMP-2, ketorolac, and amoxicillin were used as the growth factor, analgesic, and antimicrobial agent, respectively. The in vitro properties of the nanofibrous scaffolds were characterized, and in vivo efficacy was evaluated in a rat alveolar-cleft model. The empirical data indicated that the biomolecule-incorporated scaffolds offered extended discharge of BMP-2, amoxicillin, and ketorolac for >4 weeks. The animal test outcomes also demonstrated favorable bone healing at the cleft site. Biomolecule- and drug-incorporated nanofibrous scaffolds demonstrated their efficacy in alveolar cleft treatment.


  • Open Access

    Manufacture of Binary Nanofeatured Polymeric Films Using Nanosphere Lithography and Ultraviolet Roller Imprinting

    by Demei Lee, Ming-Yi Hsu, Ya-Ling Tang, Shih-Jung Liu

    This paper describes the manufacture of binary nanostructured films utilizing nanosphere lithography and ultraviolet (UV) roller imprinting. To manufacture the binary nanofeatured template, polystyrene nanocolloids of two distinct dimensions (900 and 300 nm) were primarily self-assembly spun coated on a silicon substrate. A roller imprinting facility equipped with polydimethylsiloxane molds and ultraviolet radiation was employed. During the imprinting procedure, the roller was steered by a motor and compressed the ultraviolet-curable polymeric layer against the glass substrate, where the nanofeatured layer was cured by the UV light source. Binary nanofeatured films were thus obtained. The influence of distinct processing variables on the imprinting of nanofeatured films was investigated. The empirical data suggested that with appropriate processing conditions, binary nanofeatured plastic films can be satisfactorily manufactured. It also demonstrated that roller imprinting combined with ultraviolet radiation can offer an easy yet effective method to prepare binary nanofeatured films, with a miniatured processing time and enhanced part quality.


  • Open Access

    Fast Fabrication of Nanostructured Films Using Nanocolloid Lithography and UV Soft Mold Roller Embossing: Effects of Processing Parameters

    by Demei Lee, Ya-Ling Tang, Shih-Jung Liu

    We report the fabrication of nanofeatured polymeric films using nanosphere lithography and ultraviolet (UV) soft-mold roller embossing and show an illuminative example of their application to solar cells. To prepare the nanofeatured template, polystyrene nanocolloids of two distinct sizes (900 and 300 nm) were overlaid on silicon substrates using a spin coater. A lab-made soft-mold roller embossing device equipped with a UV light source was adopted. A casting method was employed to replicate the nanofeatured template onto polydimethylsiloxane, which was used as the soft mold. During the embossing procedure, the roller was driven by a step motor and compressed the UV-curable resin against the glass substrate to form the nanofeatured layer, which was subsequently cured by UV radiation. Polymer films with nanoscaled features were thus obtained. The influence of distinct processing variables on the reproducibility of the nanofeatured films was explored. The empirical outcomes demonstrate that UV soft-mold roller embossing offers a simple yet potent way of producing nanofeatured films.


  • Open Access

    Binary Self-Assembly of Nanocolloidal Arrays using Concurrent and Sequential Spin Coating Techniques

    by Shih-Jyun Shen, Demei Lee, Yu-Chen Wu, Shih-Jung Liu

    This paper reports the binary colloid assembly of nanospheres using spin coating techniques. Polystyrene spheres with sizes of 900 and 100 nm were assembled on top of silicon substrates utilizing a spin coater. Two different spin coating processes, namely concurrent and sequential coatings, were employed. For the concurrent spin coating, 900 and 100 nm colloidal nanospheres of latex were first mixed and then simultaneously spin coated onto the silicon substrate. On the other hand, the sequential coating process first created a monolayer of a 900 nm nanosphere array on the silicon substrate, followed by the spin coating of another layer of a 100 nm colloidal array on top of the 900 nm array. The influence of the processing parameters, including the type of surfactant, spin speed, and spin time, on the self-assembly of the binary colloidal array were explored. The empirical outcomes show that by employing the optimal processing conditions, binary colloidal arrays can be achieved by both the concurrent and sequential spin coating processes.