Richard S. Figliola
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Research Interests
Richard S. Figliola has a total of 36 co-authors. Here are the top co-authors by number of shared publications:
- Giancarlo Pennati
Politecnico di Milano
3 shared publications - Alison Lesley Marsden
Institute for Computational and Mathematical Engineering, Stanford University, Stanford, USA
2 shared publications Tain-Yen Hsia
Great Ormond Street Hospital, London, UK
2 shared publications- Tain-Yen Hsia
Centre for Cardiovascular Imaging, University College London, Institute of Cardiovascular Science & Cardiorespiratory Unit, Great Ormond Street Hospital for Children, London, United Kingdom
2 shared publications Timothy Conover
From the *Mechanical and Bioengineering Engineering, Clemson University, Clemson, South Carolina; †Laboratory of Biological Structure Mechanics, Politecnico di Milano, Milan, Italy; and ‡Cardiothoracic Surgery, Great Ormond Street Hospital for Children, London, United Kingdom
2 shared publications- Alan Palazzolo
Department of Mechanical Engineering, Texas A&M University, 3123 TAMU, College Station, TX 77843
1 shared publication
Latest Publications
- 4 September 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (11) , 1-11
Computational Fluid Dynamics Turbulence Model and Experimental Study for a Fontan Cavopulmonary Assist Device
Head-flow HQ curves for a Fontan cavopulmonary assist device (CPAD) were measured using a blood surrogate in a mock circulatory loop and simulated with various computational fluid dynamics (CFD) models. The tests benchmarked the CFD tools for further enhancement of the CPAD design. Recommended Reynolds-Averaged Navier–Stokes (RANS) CFD approaches for the development of conventional ventricular assist devices (VAD) were found to have shortcomings when applied to the Fontan CPAD, which is designed to neutralize off-condition obstruction risks that could contribute to a major adverse event. The no-obstruction condition is achieved with a von Karman pump, utilizing large clearances and small blade heights, which challenge conventional VAD RANS-based CFD hemodynamic simulations. High-fidelity large eddy simulation (LES) is always recommended; however, this may be cost-inhibitive for optimization studies in commercial settings, thus the reliance on RANS models. This study compares head and power predictions of various RANS turbulence models, employing experimental measurements and LES results as a basis for comparison. The models include standard k−ϵ, re-normalization group k−ϵ, realizable k−ϵ, shear stress transport (SST) k−ω, SST with transitional turbulence, and Generalized k−ω. For the pressure head predictions, it was observed that the standard k−ϵ model provided far better agreement with experiment. For the rotor torque, k−ϵ predictions were 30% lower than LES, while the SST and LES torque values were near identical. For the Fontan CPAD, the findings support using LES for the final design simulations, k−ϵ model for head and general flow simulation, and SST for power, shear stress, hemolysis, and thrombogenicity predictions.
- 4 September 2023
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 145 (11) , 1-11
Computational Fluid Dynamics Turbulence Model and Experimental Study for a Fontan Cavopulmonary Assist Device
Head-flow HQ curves for a Fontan cavopulmonary assist device (CPAD) were measured using a blood surrogate in a mock circulatory loop and simulated with various computational fluid dynamics (CFD) models. The tests benchmarked the CFD tools for further enhancement of the CPAD design. Recommended Reynolds-Averaged Navier–Stokes (RANS) CFD approaches for the development of conventional ventricular assist devices (VAD) were found to have shortcomings when applied to the Fontan CPAD, which is designed to neutralize off-condition obstruction risks that could contribute to a major adverse event. The no-obstruction condition is achieved with a von Karman pump, utilizing large clearances and small blade heights, which challenge conventional VAD RANS-based CFD hemodynamic simulations. High-fidelity large eddy simulation (LES) is always recommended; however, this may be cost-inhibitive for optimization studies in commercial settings, thus the reliance on RANS models. This study compares head and power predictions of various RANS turbulence models, employing experimental measurements and LES results as a basis for comparison. The models include standard k−ϵ, re-normalization group k−ϵ, realizable k−ϵ, shear stress transport (SST) k−ω, SST with transitional turbulence, and Generalized k−ω. For the pressure head predictions, it was observed that the standard k−ϵ model provided far better agreement with experiment. For the rotor torque, k−ϵ predictions were 30% lower than LES, while the SST and LES torque values were near identical. For the Fontan CPAD, the findings support using LES for the final design simulations, k−ϵ model for head and general flow simulation, and SST for power, shear stress, hemolysis, and thrombogenicity predictions.
- 14 July 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (3) , 256-267
In Vitro Assessment of the Assisted Bidirectional Glenn Procedure for Stage One Single Ventricle Repair
This in vitro study compares the hemodynamic performance of the Norwood and the Glenn circulations to assess the performance of a novel assisted bidirectional Glenn (ABG) procedure for stage one single ventricle surgery. In the ABG, the flow in a bidirectional Glenn procedure is assisted by injection of a high-energy flow stream from the systemic circulation using an aorta-caval shunt with nozzle. The aim is to explore experimentally the potential of the ABG as a surgical alternative to current surgical practice. The experiments are directly compared against previously published numerical simulations. A multiscale mock circulatory system was used to measure the hemodynamic performance of the three circulations. For each circulation, the system was tested using both low and high values of pulmonary vascular resistance. Resulting parameters measured were: pressure and flow rate at left/right pulmonary artery and superior vena cava (SVC). Systemic oxygen delivery (OD) was calculated. A parametric study of the ratio of ABG nozzle to shunt diameter was done. We report time-based comparisons with numerical simulations for the three surgical variants tested. The ABG circulation demonstrated an increase of 30–38% in pulmonary flow with a 2–3.7 mmHg increase in SVC pressure compared to the Glenn and a 4–14% higher systemic OD than either the Norwood or the Glenn. The nozzle/shunt diameter ratio affected the local hemodynamics. These experimental results agreed with those of the numerical model: mean flow values were not significantly different (p > 0.05) while mean pressures were comparable within 1.2 mmHg. The results verify the approaches providing two tools to study this complicated circulation. Using a realistic experimental model we demonstrate the performance of a novel surgical procedure with potential to improve patient hemodynamics in early palliation of the univentricular circulation.
- 14 July 2015
- Published by Springer Nature in Cardiovascular Engineering and Technology
- Vol. 6 (3) , 256-267
In Vitro Assessment of the Assisted Bidirectional Glenn Procedure for Stage One Single Ventricle Repair
This in vitro study compares the hemodynamic performance of the Norwood and the Glenn circulations to assess the performance of a novel assisted bidirectional Glenn (ABG) procedure for stage one single ventricle surgery. In the ABG, the flow in a bidirectional Glenn procedure is assisted by injection of a high-energy flow stream from the systemic circulation using an aorta-caval shunt with nozzle. The aim is to explore experimentally the potential of the ABG as a surgical alternative to current surgical practice. The experiments are directly compared against previously published numerical simulations. A multiscale mock circulatory system was used to measure the hemodynamic performance of the three circulations. For each circulation, the system was tested using both low and high values of pulmonary vascular resistance. Resulting parameters measured were: pressure and flow rate at left/right pulmonary artery and superior vena cava (SVC). Systemic oxygen delivery (OD) was calculated. A parametric study of the ratio of ABG nozzle to shunt diameter was done. We report time-based comparisons with numerical simulations for the three surgical variants tested. The ABG circulation demonstrated an increase of 30–38% in pulmonary flow with a 2–3.7 mmHg increase in SVC pressure compared to the Glenn and a 4–14% higher systemic OD than either the Norwood or the Glenn. The nozzle/shunt diameter ratio affected the local hemodynamics. These experimental results agreed with those of the numerical model: mean flow values were not significantly different (p > 0.05) while mean pressures were comparable within 1.2 mmHg. The results verify the approaches providing two tools to study this complicated circulation. Using a realistic experimental model we demonstrate the performance of a novel surgical procedure with potential to improve patient hemodynamics in early palliation of the univentricular circulation.
- Open Access
- 1 July 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (4) , 391-399
Control of Respiration-Driven Retrograde Flow in the Subdiaphragmatic Venous Return of the Fontan Circulation
Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only when the valve leaflets were closed whereas cycle-averaged pressures improved only slightly (p < 0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance.
- 1 July 2014
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 60 (4) , 391-399
Open AccessControl of Respiration-Driven Retrograde Flow in the Subdiaphragmatic Venous Return of the Fontan Circulation
Respiration influences the subdiaphragmatic venous return in the total cavopulmonary connection (TCPC) of the Fontan circulation whereby both the inferior vena cava (IVC) and hepatic vein flows can experience retrograde motion. Controlling retrograde flows could improve patient outcomes. Using a patient-specific model within a Fontan mock circulatory system with respiration, we inserted a valve into the IVC to examine its effects on local hemodynamics while varying retrograde volumes by changing vascular impedances. A bovine valved conduit reduced IVC retrograde flow to within 3% of antegrade flow in all cases. The valve closed only under conditions supporting retrograde flow and its effects on local hemodynamics increased with larger retrograde volume. Liver and TCPC pressures improved only when the valve leaflets were closed whereas cycle-averaged pressures improved only slightly (p < 0.05) with a valve. The effectiveness of valve therapy is dependent on patient vascular impedance.
- 5 June 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (8) , 081007-08100714
A Simulation Protocol for Exercise Physiology in Fontan Patients Using a Closed Loop Lumped-Parameter Model
Background: Reduced exercise capacity is nearly universal among Fontan patients, though its etiology is not yet fully understood. While previous computational studies have attempted to model Fontan exercise, they did not fully account for global physiologic mechanisms nor directly compare results against clinical and physiologic data. Methods: In this study, we developed a protocol to simulate Fontan lower-body exercise using a closed-loop lumped-parameter model describing the entire circulation. We analyzed clinical exercise data from a cohort of Fontan patients, incorporated previous clinical findings from literature, quantified a comprehensive list of physiological changes during exercise, translated them into a computational model of the Fontan circulation, and designed a general protocol to model Fontan exercise behavior. Using inputs of patient weight, height, and if available, patient-specific reference heart rate (HR) and oxygen consumption, this protocol enables the derivation of a full set of parameters necessary to model a typical Fontan patient of a given body-size over a range of physiologic exercise levels. Results: In light of previous literature data and clinical knowledge, the model successfully produced realistic trends in physiological parameters with exercise level. Applying this method retrospectively to a set of clinical Fontan exercise data, direct comparison between simulation results and clinical data demonstrated that the model successfully reproduced the average exercise response of a cohort of typical Fontan patients. Conclusion: This work is intended to offer a foundation for future advances in modeling Fontan exercise, highlight the needs in clinical data collection, and provide clinicians with quantitative reference exercise physiologies for Fontan patients.
- 5 June 2014
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 136 (8) , 081007-08100714
A Simulation Protocol for Exercise Physiology in Fontan Patients Using a Closed Loop Lumped-Parameter Model
Background: Reduced exercise capacity is nearly universal among Fontan patients, though its etiology is not yet fully understood. While previous computational studies have attempted to model Fontan exercise, they did not fully account for global physiologic mechanisms nor directly compare results against clinical and physiologic data. Methods: In this study, we developed a protocol to simulate Fontan lower-body exercise using a closed-loop lumped-parameter model describing the entire circulation. We analyzed clinical exercise data from a cohort of Fontan patients, incorporated previous clinical findings from literature, quantified a comprehensive list of physiological changes during exercise, translated them into a computational model of the Fontan circulation, and designed a general protocol to model Fontan exercise behavior. Using inputs of patient weight, height, and if available, patient-specific reference heart rate (HR) and oxygen consumption, this protocol enables the derivation of a full set of parameters necessary to model a typical Fontan patient of a given body-size over a range of physiologic exercise levels. Results: In light of previous literature data and clinical knowledge, the model successfully produced realistic trends in physiological parameters with exercise level. Applying this method retrospectively to a set of clinical Fontan exercise data, direct comparison between simulation results and clinical data demonstrated that the model successfully reproduced the average exercise response of a cohort of typical Fontan patients. Conclusion: This work is intended to offer a foundation for future advances in modeling Fontan exercise, highlight the needs in clinical data collection, and provide clinicians with quantitative reference exercise physiologies for Fontan patients.
- 1 May 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (3) , 253-260
Mock Circulatory System of the Fontan Circulation to Study Respiration Effects on Venous Flow Behavior
We describe an in vitro model of the Fontan circulation with respiration to study subdiaphragmatic venous flow behavior. The venous and arterial connections of a total cavopulmonary connection (TCPC) test section were coupled with a physical lumped parameter (LP) model of the circulation. Intrathoracic and subdiaphragmatic pressure changes associated with normal breathing were applied. This system was tuned for two patients (5 years, 0.67 m2; 10 years, 1.2 m2) to physiological values. System function was verified by comparison to the analytical model on which it was based and by consistency with published clinical measurements. Overall, subdiaphragmatic venous flow was influenced by respiration. Flow within the arteries and veins increased during inspiration but decreased during expiration, with retrograde flow in the inferior venous territories. System pressures and flows showed close agreement with the analytical LP model (p < 0.05). The ratio of the flow rates occurring during inspiration to expiration were within the clinical range of values reported elsewhere. The approach used to set up and control the model was effective and provided reasonable comparisons with clinical data.
- 1 May 2013
- Published by Wolters Kluwer Health in ASAIO Journal
- Vol. 59 (3) , 253-260
Mock Circulatory System of the Fontan Circulation to Study Respiration Effects on Venous Flow Behavior
We describe an in vitro model of the Fontan circulation with respiration to study subdiaphragmatic venous flow behavior. The venous and arterial connections of a total cavopulmonary connection (TCPC) test section were coupled with a physical lumped parameter (LP) model of the circulation. Intrathoracic and subdiaphragmatic pressure changes associated with normal breathing were applied. This system was tuned for two patients (5 years, 0.67 m2; 10 years, 1.2 m2) to physiological values. System function was verified by comparison to the analytical model on which it was based and by consistency with published clinical measurements. Overall, subdiaphragmatic venous flow was influenced by respiration. Flow within the arteries and veins increased during inspiration but decreased during expiration, with retrograde flow in the inferior venous territories. System pressures and flows showed close agreement with the analytical LP model (p < 0.05). The ratio of the flow rates occurring during inspiration to expiration were within the clinical range of values reported elsewhere. The approach used to set up and control the model was effective and provided reasonable comparisons with clinical data.
- 5 November 2010
- Published by Elsevier in Progress in Pediatric Cardiology
- Vol. 30 (1-2) , 71-80
In vitro simulation and validation of the circulation with congenital heart defects
- 5 November 2010
- Published by Elsevier in Progress in Pediatric Cardiology
- Vol. 30 (1-2) , 71-80
In vitro simulation and validation of the circulation with congenital heart defects
- 9 February 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 128 (4) , 631-635
Comparative In Vitro Study of Bileaflet and Tilting Disk Valve Behavior in the Pulmonary Position
A study of mechanical heart valve behavior in the pulmonary position as a function of pulmonary vascular resistance is reported for the St. Jude Medical bileaflet (SJMB) valve and the MedicalCV Omnicarbon (OTD) tilting disk valve. Tests were conducted in a pulmonic mock circulatory system and impedance was varied in terms of system pulmonary vascular resistance (PVR). An impedance spectrum was found using instantaneous pulmonary artery pressure and flow rate curves. Both valves fully opened and closed at and above a nominal PVR of 3.0mmHg∕L∕min. The SJMB valve was prone to leaflet bounce at closure, but otherwise completely closed, at settings above and below this nominal setting. At PVR values at and below 2.0mmHg∕L∕min, the SJMB valve exhibited two types of leaflet aberrant behavior: single leaflet only closure while the other leaflet fluttered, and incomplete closure where both leaflets flutter but neither remain fully closed. The OTD valve fully opened and closed to a PVR value of 1.6mmHg∕L∕min. At lower values, the valve did not close. Valves designed for the left heart can show aberrant behavior under normal conditions as pulmonary valves.
- 9 February 2006
- Published by ASME International in Journal of Biomechanical Engineering
- Vol. 128 (4) , 631-635
Comparative In Vitro Study of Bileaflet and Tilting Disk Valve Behavior in the Pulmonary Position
A study of mechanical heart valve behavior in the pulmonary position as a function of pulmonary vascular resistance is reported for the St. Jude Medical bileaflet (SJMB) valve and the MedicalCV Omnicarbon (OTD) tilting disk valve. Tests were conducted in a pulmonic mock circulatory system and impedance was varied in terms of system pulmonary vascular resistance (PVR). An impedance spectrum was found using instantaneous pulmonary artery pressure and flow rate curves. Both valves fully opened and closed at and above a nominal PVR of 3.0mmHg∕L∕min. The SJMB valve was prone to leaflet bounce at closure, but otherwise completely closed, at settings above and below this nominal setting. At PVR values at and below 2.0mmHg∕L∕min, the SJMB valve exhibited two types of leaflet aberrant behavior: single leaflet only closure while the other leaflet fluttered, and incomplete closure where both leaflets flutter but neither remain fully closed. The OTD valve fully opened and closed to a PVR value of 1.6mmHg∕L∕min. At lower values, the valve did not close. Valves designed for the left heart can show aberrant behavior under normal conditions as pulmonary valves.