Z. Laura Tabatabai
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Z. Laura Tabatabai has a total of 45 co-authors. Here are the top co-authors by number of shared publications:
Barbara A. Crothers
2 shared publicationsDaniel F. I. Kurtycz
University of Wisconsin School of Medicine and Public Health, Wisconsin State Laboratory of Hygiene
2 shared publicationsRhona J. Souers
2 shared publicationsAlice Laser
1 shared publication- Andrew Field
Department of Anatomical Pathology, St Vincent's Hospital, Sydney, Australia
1 shared publication Celeste N. Powers
VCU Health System, Medical College of Virginia Hospitals
1 shared publication
Latest Publications
- 27 June 2023
- Published by Springer Nature
- p. 49-70
Atypia of Undetermined Significance (AUS)
- Open Access
Elevated Tumor Lactate and Efflux in High-grade Prostate Cancer demonstrated by Hyperpolarized 13C Magnetic Resonance Spectroscopy of Prostate Tissue Slice Cultures
Non-invasive assessment of the biological aggressiveness of prostate cancer (PCa) is needed for men with localized disease. Hyperpolarized (HP) 13C magnetic resonance (MR) spectroscopy is a powerful approach to image metabolism, specifically the conversion of HP [1-13C]pyruvate to [1-13C]lactate, catalyzed by lactate dehydrogenase (LDH). Significant increase in tumor lactate was measured in high-grade PCa relative to benign and low-grade cancer, suggesting that HP 13C MR could distinguish low-risk (Gleason score ≤3 + 4) from high-risk (Gleason score ≥4 + 3) PCa. To test this and the ability of HP 13C MR to detect these metabolic changes, we cultured prostate tissues in an MR-compatible bioreactor under continuous perfusion. 31P spectra demonstrated good viability and dynamic HP 13C-pyruvate MR demonstrated that high-grade PCa had significantly increased lactate efflux compared to low-grade PCa and benign prostate tissue. These metabolic differences are attributed to significantly increased LDHA expression and LDH activity, as well as significantly increased monocarboxylate transporter 4 (MCT4) expression in high- versus low- grade PCa. Moreover, lactate efflux, LDH activity, and MCT4 expression were not different between low-grade PCa and benign prostate tissues, indicating that these metabolic alterations are specific for high-grade disease. These distinctive metabolic alterations can be used to differentiate high-grade PCa from low-grade PCa and benign prostate tissues using clinically translatable HP [1-13C]pyruvate MR.
Open AccessElevated Tumor Lactate and Efflux in High-grade Prostate Cancer demonstrated by Hyperpolarized 13C Magnetic Resonance Spectroscopy of Prostate Tissue Slice Cultures
Non-invasive assessment of the biological aggressiveness of prostate cancer (PCa) is needed for men with localized disease. Hyperpolarized (HP) 13C magnetic resonance (MR) spectroscopy is a powerful approach to image metabolism, specifically the conversion of HP [1-13C]pyruvate to [1-13C]lactate, catalyzed by lactate dehydrogenase (LDH). Significant increase in tumor lactate was measured in high-grade PCa relative to benign and low-grade cancer, suggesting that HP 13C MR could distinguish low-risk (Gleason score ≤3 + 4) from high-risk (Gleason score ≥4 + 3) PCa. To test this and the ability of HP 13C MR to detect these metabolic changes, we cultured prostate tissues in an MR-compatible bioreactor under continuous perfusion. 31P spectra demonstrated good viability and dynamic HP 13C-pyruvate MR demonstrated that high-grade PCa had significantly increased lactate efflux compared to low-grade PCa and benign prostate tissue. These metabolic differences are attributed to significantly increased LDHA expression and LDH activity, as well as significantly increased monocarboxylate transporter 4 (MCT4) expression in high- versus low- grade PCa. Moreover, lactate efflux, LDH activity, and MCT4 expression were not different between low-grade PCa and benign prostate tissues, indicating that these metabolic alterations are specific for high-grade disease. These distinctive metabolic alterations can be used to differentiate high-grade PCa from low-grade PCa and benign prostate tissues using clinically translatable HP [1-13C]pyruvate MR.
- 19 October 2017
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 142 (1) , 53-58
Performance Characteristics of Body Fluid Cytology Analysis of 344 380 Responses From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology
Context.—: Body fluid cytology is an important diagnostic tool used to identify various conditions. However, an accurate diagnosis in this setting can sometimes be challenging. Objective.—: To identify the performance characteristics of body fluid cytology by analyzing participant responses from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology. Design.—: Participant responses from 5102 slides were analyzed for concordance to the general category (GC) and to the reference diagnosis (RD). Nonlinear mixed models were used to analyze concordance. Results.—: The overall GC concordance was 95.2%. The GC type, participant type, and preparation type were significantly associated with GC concordance (P < .001). Concordance for malignant cases was higher than it was for benign cases. Cytotechnologists had better GC concordance compared to pathologists. ThinPrep (Hologic, Marlborough, Massachusetts) slides had the highest GC concordance. Participant type, fluid type, preparation type, and participant interpretation were significantly associated with RD concordance (P < .001). Pathologists performed better than cytotechnologists did for RD concordance. Pericardial fluid had the lowest RD concordance, especially for cases with normal or reactive findings. Modified Giemsa–stained slides performed best for lymphoma and hematopoietic malignancy. Small cell carcinoma had the highest GC concordance, and its RD concordance was higher in pleural than in peritoneal fluids. Adenocarcinoma showed the highest concordance rates for both GC and RD. Conclusions.—: This study illustrates the challenges associated with interpreting body fluid cytology, particularly in pericardial fluid, and the factors that may affect accurate diagnoses. The results also highlight the value of using multiple preparation types in challenging cases.
- 19 October 2017
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 142 (1) , 53-58
Performance Characteristics of Body Fluid Cytology Analysis of 344 380 Responses From the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology
Context.—: Body fluid cytology is an important diagnostic tool used to identify various conditions. However, an accurate diagnosis in this setting can sometimes be challenging. Objective.—: To identify the performance characteristics of body fluid cytology by analyzing participant responses from the College of American Pathologists Interlaboratory Comparison Program in Nongynecologic Cytopathology. Design.—: Participant responses from 5102 slides were analyzed for concordance to the general category (GC) and to the reference diagnosis (RD). Nonlinear mixed models were used to analyze concordance. Results.—: The overall GC concordance was 95.2%. The GC type, participant type, and preparation type were significantly associated with GC concordance (P < .001). Concordance for malignant cases was higher than it was for benign cases. Cytotechnologists had better GC concordance compared to pathologists. ThinPrep (Hologic, Marlborough, Massachusetts) slides had the highest GC concordance. Participant type, fluid type, preparation type, and participant interpretation were significantly associated with RD concordance (P < .001). Pathologists performed better than cytotechnologists did for RD concordance. Pericardial fluid had the lowest RD concordance, especially for cases with normal or reactive findings. Modified Giemsa–stained slides performed best for lymphoma and hematopoietic malignancy. Small cell carcinoma had the highest GC concordance, and its RD concordance was higher in pleural than in peritoneal fluids. Adenocarcinoma showed the highest concordance rates for both GC and RD. Conclusions.—: This study illustrates the challenges associated with interpreting body fluid cytology, particularly in pericardial fluid, and the factors that may affect accurate diagnoses. The results also highlight the value of using multiple preparation types in challenging cases.
- 1 December 2015
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 139 (12) , 1525-1530
Performance Characteristics of Adenoid Cystic Carcinoma of the Salivary Glands in Fine-Needle Aspirates: Results From the College of American Pathologists Nongynecologic Cytology Program
Context: Although the cytomorphology of adenoid cystic carcinoma (ACC) has been well described, the accuracy of this diagnosis in fine-needle aspirates (FNAs) of the salivary glands has not been extensively evaluated. Objective: To assess participants' responses in the College of American Pathologists (CAP) Nongynecologic Cytology (NGC) Program to determine the accuracy and false-negative rate of ACC cases in salivary gland FNAs. Design: A retrospective review of the CAP NGC Program's cumulative data from 2000–2010 was performed for the general and the specific reference diagnosis categories for ACC in salivary gland FNAs according to preparation and participant types. Results: Of 5156 responses, the overall concordance rates for both the general category of malignancy and the specific category of ACC were 63.6% (3279 of 5156) and 38.6% (1966 of 5088), respectively, with a false-negative rate of 36.4% (1877 of 5156). The most frequent false-negative responses were pleomorphic (1080) and monomorphic (526) adenoma (1614 of 5088, 31.5%), while lymphoma was the most frequent malignant misinterpretation. There was a significant statistical difference in concordance to the reference interpretation between the reader types: 39.9% (1006 of 2521) concordance rate for pathologists compared to 33.8% (503 of 1488) for cytotechnologists. However, there was no significant statistical difference for concordance to the general category or reference interpretation, based on preparation type (Papanicolaou versus modified Giemsa stained). Conclusions: In this interlaboratory comparison educational program, accurate identification of ACC has shown to be problematic, with ACC representing an important cause of false-negative responses. The most common diagnostic pitfall is distinguishing this entity from pleomorphic and monomorphic adenoma in the benign category and from lymphoma and adenocarcinoma in the malignant one.
- 1 December 2015
- Published by Archives of Pathology and Laboratory Medicine in Archives of Pathology & Laboratory Medicine
- Vol. 139 (12) , 1525-1530
Performance Characteristics of Adenoid Cystic Carcinoma of the Salivary Glands in Fine-Needle Aspirates: Results From the College of American Pathologists Nongynecologic Cytology Program
Context: Although the cytomorphology of adenoid cystic carcinoma (ACC) has been well described, the accuracy of this diagnosis in fine-needle aspirates (FNAs) of the salivary glands has not been extensively evaluated. Objective: To assess participants' responses in the College of American Pathologists (CAP) Nongynecologic Cytology (NGC) Program to determine the accuracy and false-negative rate of ACC cases in salivary gland FNAs. Design: A retrospective review of the CAP NGC Program's cumulative data from 2000–2010 was performed for the general and the specific reference diagnosis categories for ACC in salivary gland FNAs according to preparation and participant types. Results: Of 5156 responses, the overall concordance rates for both the general category of malignancy and the specific category of ACC were 63.6% (3279 of 5156) and 38.6% (1966 of 5088), respectively, with a false-negative rate of 36.4% (1877 of 5156). The most frequent false-negative responses were pleomorphic (1080) and monomorphic (526) adenoma (1614 of 5088, 31.5%), while lymphoma was the most frequent malignant misinterpretation. There was a significant statistical difference in concordance to the reference interpretation between the reader types: 39.9% (1006 of 2521) concordance rate for pathologists compared to 33.8% (503 of 1488) for cytotechnologists. However, there was no significant statistical difference for concordance to the general category or reference interpretation, based on preparation type (Papanicolaou versus modified Giemsa stained). Conclusions: In this interlaboratory comparison educational program, accurate identification of ACC has shown to be problematic, with ACC representing an important cause of false-negative responses. The most common diagnostic pitfall is distinguishing this entity from pleomorphic and monomorphic adenoma in the benign category and from lymphoma and adenocarcinoma in the malignant one.
- Open Access
- 1 January 2014
- Published by Scientific Scholar in Cytojournal
- Vol. 11 (2) , 40
Post-brushing and fine-needle aspiration biopsy follow-up and treatment options for patients with pancreatobiliary lesions: The Papanicolaou Society of Cytopathology Guidelines
The Papanicolaou Society of Cytopathology (PSC) has developed a set of guidelines for pancreatobiliary cytology including indications for endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) biopsy, techniques of EUS-FNA, terminology and nomenclature for pancreatobiliary cytology, ancillary testing and post-procedure management. All documents are based on the expertise of the authors, a review of the literature and discussions of the draft document at several national and international meetings over an 18 month period and synthesis of online comments of the draft document on the PSC web site (www.papsociety.org). This document selectively presents the results of these discussions and focuses on the follow-up and treatment options for patients after procedures performed for obtaining cytology samples for the evaluation of biliary strictures and solid and cystic masses in the pancreas. These recommendations follow the six-tiered terminology and nomenclature scheme proposed by committee III
- 1 January 2014
- Published by Scientific Scholar in Cytojournal
- Vol. 11 (2) , 40
Open AccessPost-brushing and fine-needle aspiration biopsy follow-up and treatment options for patients with pancreatobiliary lesions: The Papanicolaou Society of Cytopathology Guidelines
The Papanicolaou Society of Cytopathology (PSC) has developed a set of guidelines for pancreatobiliary cytology including indications for endoscopic ultrasound (EUS) guided fine-needle aspiration (FNA) biopsy, techniques of EUS-FNA, terminology and nomenclature for pancreatobiliary cytology, ancillary testing and post-procedure management. All documents are based on the expertise of the authors, a review of the literature and discussions of the draft document at several national and international meetings over an 18 month period and synthesis of online comments of the draft document on the PSC web site (www.papsociety.org). This document selectively presents the results of these discussions and focuses on the follow-up and treatment options for patients after procedures performed for obtaining cytology samples for the evaluation of biliary strictures and solid and cystic masses in the pancreas. These recommendations follow the six-tiered terminology and nomenclature scheme proposed by committee III