Elisabetta Saraceni
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Elisabetta Saraceni has a total of 20 co-authors. Here are the top co-authors by number of shared publications:
- Alessandro De Cassai
Department of Medicine (DIMED), University of Padua, Padua, Italy
1 shared publication - Anna Da Roit
Division of Upper Gastrointestinal Surgery, Department of Surgery, Humanitas Research Hospital, 20089 Milan, Italy
1 shared publication - Carlo Castoro
Upper Gastrointestinal Surgery Unit, IRCCS Humanitas Research Hospital, Milan, Italy
1 shared publication - Eleonora Pinto
Hospital Psychology, Veneto Institute of Oncology IOV-IRCCS, 35128 Padua, Italy
1 shared publication - Elisa Pizzolato
Surgical Oncology Unit, Veneto Institute of Oncology (IOV-IRCCS), via Gattamelata 64, 35128 Padova, Italy
1 shared publication - Fabio Baratto
UOC Anaesthesia and Intensive Care Unit, Hospital of Padova, 2 Giustiniani Street, 35128 Padova, Italy
1 shared publication
Latest Publications
- Open Access
- 13 June 2022
- Published by Springer Nature in Journal of Anesthesia, Analgesia and Critical Care
- Vol. 2 (1) , 1-3
A rare case of a patient with cystinosis and COVID-19 pneumonia with difficult weaning from mechanical ventilation: the “pocus force”
Here, we describe the case of a 39-year-old woman with cystinosis who already suffered from an extra parenchymal pattern of restrictive lung disease and, after SARS-CoV-2-related respiratory failure, had a difficult weaning from mechanical ventilation and required tracheostomy. In this rare disease, due to the mutation of the CTNS-gene located on chromosome 17p13, cystine accumulation in the distal muscle has been reported, even in the absence of manifest muscle fatigue. We were able to evaluate diaphragmatic weakness in this patient through the ultrasonographic evaluation of the diaphragm. We believe that diaphragm ultrasonography could be helpful to identify causes of difficult weaning thus supporting clinical decisions.
- 13 June 2022
- Published by Springer Nature in Journal of Anesthesia, Analgesia and Critical Care
- Vol. 2 (1) , 1-3
Open AccessA rare case of a patient with cystinosis and COVID-19 pneumonia with difficult weaning from mechanical ventilation: the “pocus force”
Here, we describe the case of a 39-year-old woman with cystinosis who already suffered from an extra parenchymal pattern of restrictive lung disease and, after SARS-CoV-2-related respiratory failure, had a difficult weaning from mechanical ventilation and required tracheostomy. In this rare disease, due to the mutation of the CTNS-gene located on chromosome 17p13, cystine accumulation in the distal muscle has been reported, even in the absence of manifest muscle fatigue. We were able to evaluate diaphragmatic weakness in this patient through the ultrasonographic evaluation of the diaphragm. We believe that diaphragm ultrasonography could be helpful to identify causes of difficult weaning thus supporting clinical decisions.
- Open Access
- 9 January 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (2) , 213
Cardiac Output Evaluation on Septic Shock Patients: Comparison between Calibrated and Uncalibrated Devices during Vasopressor Therapy
There are no reliable, non-invasive methods to accurately measure cardiac output (CO) in septic patients. MostCare (Vytech Health™, Vygon, Padova, Italy), is a beat-to-beat, self calibrated method for CO measurement based on continuous analysis of reflected arterial pressure waveforms. We enrolled 40 patients that were suffering from septic shock and requiring norepinephrine infusion to target blood pressure in order to to evaluate the level of agreement between a calibrated transpulmonary thermodilution device (PiCCO System, Pulsion Medical Systems, Feldkirchen, Germany) and the MostCare system in detecting and tracking changes in CO measurements related to norepinephrine reduction in septic shock patients,. PiCCO was connected to a 5 Fr femoral artery catheter and to a central venous catheter. System calibration was performed with 15 mL of cold saline injection over about 3 s. The MostCare device was connected to the artery catheter to analyze the arterial waveform. Before reducing norepinephrine infusion, the PiCCO system was calibrated, the MostCare waveform was optimized, and the values of the complete hemodynamic profile were recorded (T1). Norepinephrine infusion was then reduced by 0.03 mcg/Kg/min. After 30 min, a new calibration of PiCCO system and a new record on both monitors were performed (T2). Static measurements agreements were assessed using the Bland-Altman test, while trending ability was investigated using polar plot analysis. If volume expansion occurred, then related data were separately analyzed. At T1 mean the CO was 5.38 (SD 0.60) L/min, the mean difference was 0.176 L/min, the limits of agreement (LoA) was +1.39 and −1.04 L/min, and the percentage error (PE) was 22.6%; at T2 the mean CO was 5.44 (SD 0.73) L/min, the mean difference was 0.053 L/min, the LoA was +1.51 and −1.40, and the PE was 27%. After considering the volume expansion between T1 and T2, the mean CO at T1 was 5.39 L/min (SD 0.47), the LoA was +1.09 and −0.78 L/min, and the percentage error (PE) was 17%; at T2 the mean CO was 5.35 L/min (SD 0.81), the LoA was +1.73 and −1.52 L/min, and the PE was 30%. The polar plot diagram seems to confirm the trending ability of MostCare system versus the reference method. In septic patients, when the arterial waveform is accurate, MostCare and PiCCO transpulmonary thermodilution exhibit good agreement even after the reduction of norepinephrine and changes in vascular tone or volume expansion. MostCare could be a rapid to set, reliable, and useful tool to monitor hemodynamic variations in septic patients in emergency contexts where thermodilution methods or other advanced systems are not easily available.
- 9 January 2021
- Published by MDPI AG in Journal of Clinical Medicine
- Vol. 10 (2) , 213
Open AccessCardiac Output Evaluation on Septic Shock Patients: Comparison between Calibrated and Uncalibrated Devices during Vasopressor Therapy
There are no reliable, non-invasive methods to accurately measure cardiac output (CO) in septic patients. MostCare (Vytech Health™, Vygon, Padova, Italy), is a beat-to-beat, self calibrated method for CO measurement based on continuous analysis of reflected arterial pressure waveforms. We enrolled 40 patients that were suffering from septic shock and requiring norepinephrine infusion to target blood pressure in order to to evaluate the level of agreement between a calibrated transpulmonary thermodilution device (PiCCO System, Pulsion Medical Systems, Feldkirchen, Germany) and the MostCare system in detecting and tracking changes in CO measurements related to norepinephrine reduction in septic shock patients,. PiCCO was connected to a 5 Fr femoral artery catheter and to a central venous catheter. System calibration was performed with 15 mL of cold saline injection over about 3 s. The MostCare device was connected to the artery catheter to analyze the arterial waveform. Before reducing norepinephrine infusion, the PiCCO system was calibrated, the MostCare waveform was optimized, and the values of the complete hemodynamic profile were recorded (T1). Norepinephrine infusion was then reduced by 0.03 mcg/Kg/min. After 30 min, a new calibration of PiCCO system and a new record on both monitors were performed (T2). Static measurements agreements were assessed using the Bland-Altman test, while trending ability was investigated using polar plot analysis. If volume expansion occurred, then related data were separately analyzed. At T1 mean the CO was 5.38 (SD 0.60) L/min, the mean difference was 0.176 L/min, the limits of agreement (LoA) was +1.39 and −1.04 L/min, and the percentage error (PE) was 22.6%; at T2 the mean CO was 5.44 (SD 0.73) L/min, the mean difference was 0.053 L/min, the LoA was +1.51 and −1.40, and the PE was 27%. After considering the volume expansion between T1 and T2, the mean CO at T1 was 5.39 L/min (SD 0.47), the LoA was +1.09 and −0.78 L/min, and the percentage error (PE) was 17%; at T2 the mean CO was 5.35 L/min (SD 0.81), the LoA was +1.73 and −1.52 L/min, and the PE was 30%. The polar plot diagram seems to confirm the trending ability of MostCare system versus the reference method. In septic patients, when the arterial waveform is accurate, MostCare and PiCCO transpulmonary thermodilution exhibit good agreement even after the reduction of norepinephrine and changes in vascular tone or volume expansion. MostCare could be a rapid to set, reliable, and useful tool to monitor hemodynamic variations in septic patients in emergency contexts where thermodilution methods or other advanced systems are not easily available.
- Open Access
- 1 January 2014
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 12 (1) , 156
Sleep disturbances and quality of life in postoperative management after esophagectomy for esophageal cancer
The aims of this prospective study were to analyze the predictors of postoperative sleep disturbance after esophagectomy for cancer and to identify patients at risk for postoperative hypnotic administration.
- 1 January 2014
- Published by Springer Nature in World Journal of Surgical Oncology
- Vol. 12 (1) , 156
Open AccessSleep disturbances and quality of life in postoperative management after esophagectomy for esophageal cancer
The aims of this prospective study were to analyze the predictors of postoperative sleep disturbance after esophagectomy for cancer and to identify patients at risk for postoperative hypnotic administration.