Bishara Bishara
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Bishara Bishara has a total of 10 co-authors. Here are the top co-authors by number of shared publications:
- Ahmad Mahajna
Department of general surgery, Rambam Health Care Campus, Haifa, Israel
2 shared publications - Ahmad Assalia
Department of General Surgery, Rambam Health Care Campus, and The Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, 8 Ha’Aliyah Street, Haifa 35254, Israel
1 shared publication - Alexander Braginski
Department of Anesthesiology, Baruch Padeh Medical Center, Poriya, Tiberias, Israel
1 shared publication Benyamine Abbou
Department of Surgery A', Rambam Medical Center, and The Bruce Rappaport Faculty of Medicine, Technion-Israel Institute of Technology, Haifa, Israel
1 shared publication- Dan D. Hershko
Department of Surgery A, Rambam Medical Center, 31096 Haifa, Israel
1 shared publication - Michael M. Krausz
Laboratory for Shock and Trauma Research and Department of Surgery A, and †Department of Neurosurgery, Rambam Health Care Campus and Technion-Israel Institute of Technology, Haifa; ‡Division of Anesthesiology, Soroka Medical Center, Ben-Gurion University of the Negev, Beer-Sheva; and §Department of Anesthesiology, Carmel Medical Center, Haifa, Israel
1 shared publication
Latest Publications
- Open Access
- 5 May 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 31
The use of VivaSight™ single lumen endotracheal tube in morbidly obese patients undergoing laparoscopic sleeve gastrectomy
The population of obese patients is progressively growing and bariatric operations are becoming increasingly common. Morbidly obese patients require special anesthetic care and are often considered to be difficult to ventilate and intubate. The VivaSight™ Single Lumen tube is an endotracheal tube with a camera embedded in its tip. The view from the tip appears continuously on a monitor in the anesthesiologist's vicinity. The aim of this study was to assess the VivaSight™ in comparison with conventional endotracheal tube as an aid in the intubation and surveillance of tube position during surgery of obese patients.
- 5 May 2014
- Published by Springer Nature in BMC Anesthesiology
- Vol. 14 (1) , 31
Open AccessThe use of VivaSight™ single lumen endotracheal tube in morbidly obese patients undergoing laparoscopic sleeve gastrectomy
The population of obese patients is progressively growing and bariatric operations are becoming increasingly common. Morbidly obese patients require special anesthetic care and are often considered to be difficult to ventilate and intubate. The VivaSight™ Single Lumen tube is an endotracheal tube with a camera embedded in its tip. The view from the tip appears continuously on a monitor in the anesthesiologist's vicinity. The aim of this study was to assess the VivaSight™ in comparison with conventional endotracheal tube as an aid in the intubation and surveillance of tube position during surgery of obese patients.
- Open Access
- 1 January 2006
- Published by Springer Nature in World Journal of Emergency Surgery
- Vol. 1 (1) , 3
Laparoscopic diagnostic peritoneal lavage (L-DPL): A method for evaluation of penetrating abdominal stab wounds
- 1 January 2006
- Published by Springer Nature in World Journal of Emergency Surgery
- Vol. 1 (1) , 3
Open AccessLaparoscopic diagnostic peritoneal lavage (L-DPL): A method for evaluation of penetrating abdominal stab wounds