Yisha Tong
Current Organizations / Institutes
The organizations/institutes from the scholar's latest article
Previous Organizations / Institutes
The organizations / institutes from the scholar's other articles in the past ten years
Research Subjects
Yisha Tong has a total of 27 co-authors. Here are the top co-authors by number of shared publications:
Haining Zheng
Department of Ultrasound, Peking University International Hospital, Beijing, China
4 shared publications- Chaoyang Wen
Department of Ultrasound, Peking University International Hospital, Beijing, China
3 shared publications Rui Zhao
Department of Ultrasound, Peking University International Hospital, Beijing, China
3 shared publicationsYigang Du
Ultrasound R&D Department, Shenzhen Mindray Bio-Medical Electronics Co., Ltd., Shenzhen, China
3 shared publications- Chaoyang Wen
Department of Ultrasound, Peking University International Hospital, Beijing, China
2 shared publications Wei Wang
Department of Ultrasound, the Fourth Medical Center of PLA General Hospital, Beijing, China
2 shared publications
Latest Publications
- Open Access
- 25 March 2026
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 54 (6) , 1477-1488
Economic and Regional Disparities in Critical Care Ultrasound Training, Equipment Access, and Implementation Barriers in China: A Nationwide Cross-Sectional Survey
OBJECTIVES: To assess critical care ultrasound (CCUS) utilization, training coverage, and barriers to implementation among ICU clinicians across economically diverse regions in China. DESIGN: An online cross-sectional survey with chi-square tests, Mann-Whitney U tests, multivariate logistic regression, and principal component analysis (PCA)-based clustering. SETTING: ICU clinicians from all 31 provincial-level regions in mainland China, classified into high- and low-gross domestic product (GDP) groups by per capita GDP relative to the national average. SUBJECTS: Six hundred fifty-five ICU clinicians who completed the survey. INTERVENTIONS: The survey included demographics, CCUS training experience, equipment availability, clinical usage frequency, and perceived implementation barriers. MEASUREMENTS AND MAIN RESULTS: A total of 61.4% of respondents reported receiving CCUS training, with similar coverage between high- and low-GDP regions (61.9% vs. 60.8%; p = 0.769). Clinicians from high-GDP areas reported significantly higher self-assessed ultrasound proficiency ( p = 0.008). Dedicated ultrasound equipment was unavailable in approximately one-third of ICUs, slightly more common in low-GDP regions (37.7% vs. 31.4%; p = 0.094). Major barriers included insufficient expert support (36.9%), lack of ultrasound consultants (31.3%), and difficulties in image interpretation (31.1%). Logistic regression analysis showed structured training significantly reduced the odds of encountering equipment-related barriers (odds ratio, 0.57; 95% CI, 0.34–0.97; p = 0.036). PCA-based clustering identified three clinician profiles: frequent users (high training and usage, predominantly from high-GDP areas), moderate users, and infrequent users (limited training and primarily from low-GDP regions). CONCLUSIONS: Structured CCUS training significantly enhances utilization and clinician expertise, irrespective of regional economic conditions. Policies promoting standardized training, equitable equipment distribution, and sustainable expert support are essential for broader CCUS integration in critical care settings across China.
- 25 March 2026
- Published by Wolters Kluwer Health in Critical Care Medicine
- Vol. 54 (6) , 1477-1488
Open AccessEconomic and Regional Disparities in Critical Care Ultrasound Training, Equipment Access, and Implementation Barriers in China: A Nationwide Cross-Sectional Survey
OBJECTIVES: To assess critical care ultrasound (CCUS) utilization, training coverage, and barriers to implementation among ICU clinicians across economically diverse regions in China. DESIGN: An online cross-sectional survey with chi-square tests, Mann-Whitney U tests, multivariate logistic regression, and principal component analysis (PCA)-based clustering. SETTING: ICU clinicians from all 31 provincial-level regions in mainland China, classified into high- and low-gross domestic product (GDP) groups by per capita GDP relative to the national average. SUBJECTS: Six hundred fifty-five ICU clinicians who completed the survey. INTERVENTIONS: The survey included demographics, CCUS training experience, equipment availability, clinical usage frequency, and perceived implementation barriers. MEASUREMENTS AND MAIN RESULTS: A total of 61.4% of respondents reported receiving CCUS training, with similar coverage between high- and low-GDP regions (61.9% vs. 60.8%; p = 0.769). Clinicians from high-GDP areas reported significantly higher self-assessed ultrasound proficiency ( p = 0.008). Dedicated ultrasound equipment was unavailable in approximately one-third of ICUs, slightly more common in low-GDP regions (37.7% vs. 31.4%; p = 0.094). Major barriers included insufficient expert support (36.9%), lack of ultrasound consultants (31.3%), and difficulties in image interpretation (31.1%). Logistic regression analysis showed structured training significantly reduced the odds of encountering equipment-related barriers (odds ratio, 0.57; 95% CI, 0.34–0.97; p = 0.036). PCA-based clustering identified three clinician profiles: frequent users (high training and usage, predominantly from high-GDP areas), moderate users, and infrequent users (limited training and primarily from low-GDP regions). CONCLUSIONS: Structured CCUS training significantly enhances utilization and clinician expertise, irrespective of regional economic conditions. Policies promoting standardized training, equitable equipment distribution, and sustainable expert support are essential for broader CCUS integration in critical care settings across China.
- Open Access
- 27 October 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1597407
Wall shear stress and oscillatory shear index measured using ultrasound vector flow imaging in the femoropopliteal artery of adults without peripheral artery disease
Objective: To measure wall shear stress (WSS), oscillatory shear index (OSI) and relative residence time (RRT) at multiple locations along the femoropopliteal artery in adults without peripheral artery disease (PAD), and to investigate whether low WSS, high OSI and/or high RRT are present in regions with a high prevalence of atherosclerotic lesions. Materials and methods: A total of 116 presumed healthy adult volunteers were recruited. Ankle-brachial index and lower-limb arterial duplex ultrasound assessments were performed to exclude participants with PAD. Maximum WSS, mean WSS, and OSI were measured at the near and far walls of ten arterial sites along the femoropopliteal artery using ultrasound vector flow imaging (VFI). RRT was calculated from OSI and mean WSS values obtained via VFI. Results: A total of 113 participants (46 males and 67 females; 222 lower limbs), with a mean age of 37.6 years, were included in the analysis. Compared to the overall mean values across all 20 measurement sites, significantly higher OSI and higher RRT were recorded at the posterior wall of the common femoral artery ( P < 0.01), while significantly lower WSS, higher OSI, and higher RRT were observed at the posterior wall of the femoral artery bifurcation ( P < 0.01). The distal superficial femoral artery (SFA) at the adductor canal demonstrated significantly lower WSS and higher OSI at both near and far walls ( P < 0.01). When comparing hemodynamic indices between sexes, males exhibited significantly lower WSS at several near-wall sites, significantly higher OSI at multiple near- and far-wall sites, and significantly higher RRT at the near wall of the proximal SFA and the far wall of the profunda femoris artery ( P < 0.05). Conclusions: Variations in WSS, OSI, and RRT are evident along the femoropopliteal artery in adults without PAD. Notably, the distal SFA at the adductor canal demonstrated significantly lower and more oscillatory WSS, consistent with the region's reported high prevalence of atherosclerotic plaque and occlusion. Whether these hemodynamic patterns contribute to lesion development later in life remains uncertain and warrants further investigation.
- 27 October 2025
- Published by Frontiers Media SA in Frontiers in Surgery
- Vol. 12, 1597407
Open AccessWall shear stress and oscillatory shear index measured using ultrasound vector flow imaging in the femoropopliteal artery of adults without peripheral artery disease
Objective: To measure wall shear stress (WSS), oscillatory shear index (OSI) and relative residence time (RRT) at multiple locations along the femoropopliteal artery in adults without peripheral artery disease (PAD), and to investigate whether low WSS, high OSI and/or high RRT are present in regions with a high prevalence of atherosclerotic lesions. Materials and methods: A total of 116 presumed healthy adult volunteers were recruited. Ankle-brachial index and lower-limb arterial duplex ultrasound assessments were performed to exclude participants with PAD. Maximum WSS, mean WSS, and OSI were measured at the near and far walls of ten arterial sites along the femoropopliteal artery using ultrasound vector flow imaging (VFI). RRT was calculated from OSI and mean WSS values obtained via VFI. Results: A total of 113 participants (46 males and 67 females; 222 lower limbs), with a mean age of 37.6 years, were included in the analysis. Compared to the overall mean values across all 20 measurement sites, significantly higher OSI and higher RRT were recorded at the posterior wall of the common femoral artery ( P < 0.01), while significantly lower WSS, higher OSI, and higher RRT were observed at the posterior wall of the femoral artery bifurcation ( P < 0.01). The distal superficial femoral artery (SFA) at the adductor canal demonstrated significantly lower WSS and higher OSI at both near and far walls ( P < 0.01). When comparing hemodynamic indices between sexes, males exhibited significantly lower WSS at several near-wall sites, significantly higher OSI at multiple near- and far-wall sites, and significantly higher RRT at the near wall of the proximal SFA and the far wall of the profunda femoris artery ( P < 0.05). Conclusions: Variations in WSS, OSI, and RRT are evident along the femoropopliteal artery in adults without PAD. Notably, the distal SFA at the adductor canal demonstrated significantly lower and more oscillatory WSS, consistent with the region's reported high prevalence of atherosclerotic plaque and occlusion. Whether these hemodynamic patterns contribute to lesion development later in life remains uncertain and warrants further investigation.
- Open Access
- 1 October 2024
- Published by Wolters Kluwer Health in Vascular Investigation and Therapy
- Vol. 7 (4) , 61-68
Investigation and management of iliac artery endofibrosis
Iliac artery endofibrosis (IAE) is a nonatherosclerotic vascular condition characterized by subintimal fibrosis of the external iliac artery (EIA). It typically affects young otherwise healthy endurance athletes, especially competitive cyclists. It causes claudication during intense sporting activities. IAE is also known as cyclist’s iliac syndrome, external iliac artery endofibrosis, iliac artery compression, iliac artery syndrome, and iliac outlet syndrome. IAE is relatively rare and perhaps underrecognized. This article reviews current knowledge of the clinical features, diagnostic investigations, and management options for IAE to help multidisciplinary healthcare professionals familiarize themselves with this condition.
- 1 October 2024
- Published by Wolters Kluwer Health in Vascular Investigation and Therapy
- Vol. 7 (4) , 61-68
Open AccessInvestigation and management of iliac artery endofibrosis
Iliac artery endofibrosis (IAE) is a nonatherosclerotic vascular condition characterized by subintimal fibrosis of the external iliac artery (EIA). It typically affects young otherwise healthy endurance athletes, especially competitive cyclists. It causes claudication during intense sporting activities. IAE is also known as cyclist’s iliac syndrome, external iliac artery endofibrosis, iliac artery compression, iliac artery syndrome, and iliac outlet syndrome. IAE is relatively rare and perhaps underrecognized. This article reviews current knowledge of the clinical features, diagnostic investigations, and management options for IAE to help multidisciplinary healthcare professionals familiarize themselves with this condition.
- Open Access
- 18 December 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1282597
Ultrasound characteristics of abdominal vascular compression syndromes
Abdominal vascular compression syndrome (AVCS) is caused by the compression of abdominal blood vessels by adjacent structures or the compression of abdominal organs by neighboring blood vessels. Such compressions can result in a variety of clinical symptoms. They are not commonly seen in ultrasound practices, and their presence may have been underrecognized and underdiagnosed. This article reviews the clinical features, ultrasound characteristics, and diagnostic criteria of four types of AVCS, namely, celiac artery compression syndrome, renal vein compression syndrome, iliac vein compression syndrome, and superior mesenteric artery syndrome to increase awareness of these conditions among ultrasound practitioners. The ultrasound criteria for AVCS are primarily based on studies with small sample sizes, and therefore, it is important to exercise caution if these criteria are used.
- 18 December 2023
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 10, 1282597
Open AccessUltrasound characteristics of abdominal vascular compression syndromes
Abdominal vascular compression syndrome (AVCS) is caused by the compression of abdominal blood vessels by adjacent structures or the compression of abdominal organs by neighboring blood vessels. Such compressions can result in a variety of clinical symptoms. They are not commonly seen in ultrasound practices, and their presence may have been underrecognized and underdiagnosed. This article reviews the clinical features, ultrasound characteristics, and diagnostic criteria of four types of AVCS, namely, celiac artery compression syndrome, renal vein compression syndrome, iliac vein compression syndrome, and superior mesenteric artery syndrome to increase awareness of these conditions among ultrasound practitioners. The ultrasound criteria for AVCS are primarily based on studies with small sample sizes, and therefore, it is important to exercise caution if these criteria are used.
- Open Access
- 20 July 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 979992
Corrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging
Corrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging
- 20 July 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 979992
Open AccessCorrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging
Corrigendum: Quantitative evaluation of post-stenotic blood flow disturbance in canine femoral artery stenosis model: An early experience with vector flow imaging
- Open Access
- 24 February 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 829825
Quantitative Evaluation of Post-stenotic Blood Flow Disturbance in Canine Femoral Artery Stenosis Model: An Early Experience With Vector Flow Imaging
Objective: To investigate the value of Vector Flow Imaging (V Flow) in the assessment of post-stenotic turbulence in the canine arterial stenosis model.Materials and Methods: Canine femoral artery stenosis models were established using ameroid constrictors in 12 beagle dogs. 50% and then 70% femoral artery stenoses were confirmed by selective femoral artery angiography. V Flow was used to measure femoral artery flow turbulence index (Tur) preoperatively as a baseline. After establishing of a 50% and then 70% stenoses, the Tur indices were recorded in the femoral artery at 1, 3, 5, 7, 9, 11, 13, 15, 17, and 19 mm distal to the stenosis.Results: Baseline Tur indices of normal canine femoral arteries were 1%) was recorded in 83.3–100% cases between 1 and 9 mm, 41.7–58.3% between 11 and 17 mm, and 16.7% at 19 mm. For a 70% stenosis, the Tur index (>1%) occurred in 81.8–100% cases between 1 and 17 mm distal to the stenosis, and 63.6% at 19 mm. The Tur index peaked around 7 mm or 2.3 times of the initial vessel diameter (3 mm) downstream for a 50% stenosis and 11 mm or 3.7 times of vessel diameter downstream for a 70% stenosis.Conclusion: V Flow with Tur index measurement adds quantitative information of post-stenotic turbulence when assessing an arterial stenosis with ultrasound. Tur index of 1% seems a useful threshold for assessment of flow turbulence in this small sample study. Further studies with larger sample size are needed to evaluate the value of V Flow in clinical applications.
- 24 February 2022
- Published by Frontiers Media SA in Frontiers in Cardiovascular Medicine
- Vol. 9, 829825
Open AccessQuantitative Evaluation of Post-stenotic Blood Flow Disturbance in Canine Femoral Artery Stenosis Model: An Early Experience With Vector Flow Imaging
Objective: To investigate the value of Vector Flow Imaging (V Flow) in the assessment of post-stenotic turbulence in the canine arterial stenosis model.Materials and Methods: Canine femoral artery stenosis models were established using ameroid constrictors in 12 beagle dogs. 50% and then 70% femoral artery stenoses were confirmed by selective femoral artery angiography. V Flow was used to measure femoral artery flow turbulence index (Tur) preoperatively as a baseline. After establishing of a 50% and then 70% stenoses, the Tur indices were recorded in the femoral artery at 1, 3, 5, 7, 9, 11, 13, 15, 17, and 19 mm distal to the stenosis.Results: Baseline Tur indices of normal canine femoral arteries were 1%) was recorded in 83.3–100% cases between 1 and 9 mm, 41.7–58.3% between 11 and 17 mm, and 16.7% at 19 mm. For a 70% stenosis, the Tur index (>1%) occurred in 81.8–100% cases between 1 and 17 mm distal to the stenosis, and 63.6% at 19 mm. The Tur index peaked around 7 mm or 2.3 times of the initial vessel diameter (3 mm) downstream for a 50% stenosis and 11 mm or 3.7 times of vessel diameter downstream for a 70% stenosis.Conclusion: V Flow with Tur index measurement adds quantitative information of post-stenotic turbulence when assessing an arterial stenosis with ultrasound. Tur index of 1% seems a useful threshold for assessment of flow turbulence in this small sample study. Further studies with larger sample size are needed to evaluate the value of V Flow in clinical applications.
- 1 January 2014
- Published by International Research and Cooperation Association for Bio & Socio-Sciences Advancement (IRCA-BSSA) in Intractable & Rare Diseases Research
- Vol. 3 (2) , 52-56
Seizures caused by pyridoxine (vitamin B6) deficiency in adults: A case report and literature review
Pyridoxine (vitamin B6) deficiency is a recognised cause of intractable seizures in neonates. However, pyridoxine deficiency related seizures in adults were rarely reported. This article reports a case of a 79 year old lady who suffered from new-onset seizures and was successfully treated with vitamin B6. The patient had chronic renal disease and weight loss due to anepithymia following a pelvic fracture. This article also reviews literatures of seizures caused by pyridoxine deficiency in adults. Seizures caused by vitamin B6 deficiency in adults may result from dietary deficiency, liver disease, pregnancy and certain medications and can be easily treated by vitamin B6 with excellent outcome. Clinicians should consider vitamin B6 deficiency as a potential aetiology of seizures, even in patients who suffer from other underlying diseases which can cause seizures.
- 1 January 2014
- Published by International Research and Cooperation Association for Bio & Socio-Sciences Advancement (IRCA-BSSA) in Intractable & Rare Diseases Research
- Vol. 3 (2) , 52-56
Seizures caused by pyridoxine (vitamin B6) deficiency in adults: A case report and literature review
Pyridoxine (vitamin B6) deficiency is a recognised cause of intractable seizures in neonates. However, pyridoxine deficiency related seizures in adults were rarely reported. This article reports a case of a 79 year old lady who suffered from new-onset seizures and was successfully treated with vitamin B6. The patient had chronic renal disease and weight loss due to anepithymia following a pelvic fracture. This article also reviews literatures of seizures caused by pyridoxine deficiency in adults. Seizures caused by vitamin B6 deficiency in adults may result from dietary deficiency, liver disease, pregnancy and certain medications and can be easily treated by vitamin B6 with excellent outcome. Clinicians should consider vitamin B6 deficiency as a potential aetiology of seizures, even in patients who suffer from other underlying diseases which can cause seizures.